Impedance-Based Short Circuit-Short Circuit Fault Location Method in Coaxial Cables

被引:1
|
作者
Bugajska, Aneta [1 ]
Desaniuk, Tomasz [2 ]
机构
[1] Kielce Univ Technol, Fac Elect Engn Automat Control & Comp Sci, PL-25314 Kielce, Poland
[2] Kielce Univ Technol, Fac Mechatron & Mech Engn, PL-25314 Kielce, Poland
关键词
Input impedance; transverse impedance; distance to the fault location; coaxial cable; diagnostic tests; SCHEME; WAVE;
D O I
10.1109/ACCESS.2023.3320641
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper presents the results of the assessment and verification of a non-destructive method of fault location in coaxial cables with a local weakening of insulation. The essence of the method is to measure the input impedance of the cable in a short circuit at both ends and, based on obtained values, to determine the transverse impedance of the fault and the distance to the fault location. For the RG59 Cable with a length of 50.0 m, with the assumed distance to the fault location of 5.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 1.8 m, for open circuit-open circuit from 0.1 m to 0.2 m and open circuit-short circuit to 0.2 m. For the RG59 Cable at the actual distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 0.7 m, for open circuit-open circuit from 0.0 m to 0.1 m and open circuit-short circuit from 0.2 m to 0.7 m. For the RF-7 Cable with a length of 100.0 m, with the assumed distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.7 m to 1.8 m, for open circuit-open circuit from 0.0 m to 0.7 m and open circuit-short circuit 0.2 m to 2.3 m. For the RF-7 Cable with the assumed distance to the fault location of 20.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.1 m to 1.2 m, for open circuit-open circuit method from 0.1 m to 0.3 m and open circuit-short circuit method from 0.1 m to 0.7 m.
引用
收藏
页码:115231 / 115279
页数:49
相关论文
共 50 条
  • [1] Impedance-Based Method of Transverse Fault Location in Medium Voltage Cables
    Bugajska, Aneta
    XIII INTERNATIONAL CONFERENCE ELECTROMACHINING 2018, 2018, 2017
  • [2] Fault Location in Double Circuit Medium Power Distribution Networks Using an Impedance-Based Method
    Dashti, Rahman
    Salehizadeh, Seyed Mehdi
    Shaker, Hamid Reza
    Tahavori, Maryamsadat
    APPLIED SCIENCES-BASEL, 2018, 8 (07):
  • [3] Single Phase Short Circuit Fault Location Method Based on Innovation Graph
    Guo, HuaiYu
    Li, Dan
    Yang, ZiHao
    Song, Zhi
    Wang, Ji
    Zhang, MingRui
    Gao, Ying
    Ning, SongTao
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 766 - 769
  • [4] Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
    Yang, Jin
    Fletcher, John E.
    O'Reilly, John
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (10) : 3827 - 3837
  • [5] Fault Location for Coaxial Cables Based on Broadband Impedance Spectroscopy
    Mo, Shi
    Zhang, Dandan
    Li, Zhenbiao
    Ye, Xuebin
    PROCEEDINGS OF 2022 12TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2022), 2022, : 143 - 148
  • [6] A Novel Approach to Impedance-Based Fault Location for High Voltage Cables
    Bi, Taihang
    Yao, Lixiao
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,
  • [7] Overvoltage of secondary cables in substation due to short circuit fault
    Meng, Yongchang
    Zhang, Bo
    Shen, Wei
    Wang, Sen
    Ma, Yutang
    2018 JOINT IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 2018 IEEE ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC/APEMC), 2018, : 1099 - 1102
  • [8] Short Circuit Power Based Fault Location Algorithm in Distribution Networks
    Farzan, Payam
    Izadi, Mahdi
    Gomes, Chandima
    Ab Kadir, Mohd Zainal Abidin
    Hesamian, M. H.
    Radzi, Mohd Amran Mohd
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 105 - 109
  • [9] Calculation of minimal short-circuit current in parallel arrangement of cables for a three phase short-circuit fault
    Ksiazkiewicz, Andrzej
    Batura, Ryszard
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (05): : 124 - 128
  • [10] Fault location method for interphase short circuit in digital distribution network based on genetic algorithm
    Cao Y.
    Zhang J.
    Zhu L.