Automatic Max-Likelihood Envelope Detection Algorithm for Quantitative High-Frame-Rate Ultrasound for Neonatal Brain Monitoring

被引:0
|
作者
Kortenbout, Anna J. [1 ]
Costerus, Sophie [2 ]
Dudink, Jeroen [3 ]
de Jong, Nico [1 ,4 ]
Graaff, Jurgen C. de [5 ,6 ,7 ]
Vos, Hendrik J. [1 ,4 ]
Bosch, Johan G. [1 ,8 ]
机构
[1] Erasmus MC, Univ Med Ctr Rotterdam, Dept Cardiol, Biomed Engn, Rotterdam, Netherlands
[2] Erasmus MC, Univ Med Ctr Rotterdam, Dept Pediat Surg, Rotterdam, Netherlands
[3] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Dept Neonatol, Utrecht, Netherlands
[4] Delft Univ Technol, Fac Appl Sci, Dept Imaging Phys, Med Imaging, Delft, Netherlands
[5] Erasmus MC, Univ Med Ctr Rotterdam, Dept Anesthesiol, Rotterdam, Netherlands
[6] Erasmus MC, Dept Anesthesiol, Goes, Netherlands
[7] Weill Cornell Med, Dept Anesthesiol, New York, NY USA
[8] Erasmus MC, Dept Cardiol, Biomed Engn, Dr Molewaterpl 60, NL-3000 CA Rotterdam, Netherlands
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2024年 / 50卷 / 03期
基金
荷兰研究理事会;
关键词
Envelope detection; Max-likelihood; Spectral Doppler; Pulsed wave Doppler; High-frame-rate ultrasound; Cerebral ultrasound; Neonates; High -risk surgery; Monitoring; FREQUENCY ESTIMATORS; DOPPLER; RISK;
D O I
10.1016/j.ultrasmedbio.2023.12.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: Post -operative brain injury in neonates may result from disturbed cerebral perfusion, but accurate perioperative monitoring is lacking. High-frame-rate (HFR) cerebral ultrasound could visualize and quantify flow in all detectable vessels using spectral Doppler; however, automated quantification in small vessels is challenging because of low signal amplitude. We have developed an automatic envelope detection algorithm for HFR pulsed wave spectral Doppler signals, enabling neonatal brain quantitative parameter maps during and after surgery. Methods: HFR ultrasound data from high -risk neonatal surgeries were recorded with a custom HFR mode (frame rate = 1000 Hz) on a Zonare ZS3 system. A pulsed wave Doppler spectrogram was calculated for each pixel containing blood flow in the image, and spectral peak velocity was tracked using a max-likelihood estimation algorithm of signal and noise regions in the spectrogram, where the most likely cross -over point marks the blood flow velocity. The resulting peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistivity index (RI) were compared with other detection schemes, manual tracking and RIs from regular pulsed wave Doppler measurements in 10 neonates. Results: Envelope detection was successful in both high- and low-quality arterial and venous flow spectrograms. Our technique had the lowest root mean square error for EDV, PSV and RI (0.46 cm/s, 0.53 cm/s and 0.15, respectively) when compared with manual tracking. There was good agreement between the clinical pulsed wave Doppler RI and HFR measurement with a mean difference of 0.07. Conclusion: The max-likelihood algorithm is a promising approach to accurate, automated cerebral blood flow monitoring with HFR imaging in neonates.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 6 条
  • [1] Algorithm for particle detection and parameterization in high-frame-rate thermal video
    Bombrun, Maxime
    Barra, Vincent
    Harris, Andrew
    JOURNAL OF APPLIED REMOTE SENSING, 2014, 8
  • [2] Moving Target Monitoring Algorithm Based on High-frame-rate SAR Images
    Chen J.
    Yang W.
    Wang Y.
    Li C.
    Journal of Radars, 2022, 11 (06) : 1048 - 1060
  • [3] Apodizing Delay and Auto-Correlation Reconstruction Algorithm for High-Frame-Rate Ultrasound Imaging
    Li, Chunqi
    Clegg, Harry R.
    Carpenter, Thomas M.
    Nie, Luzhen
    Freear, Steven
    Cowell, David M. J.
    McLaughlan, James R.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [4] Qualitative and quantitative analysis of solid renal tumors by high-frame-rate contrast-enhanced ultrasound
    Wu, Hailan
    Shi, Jiayu
    Gao, Long
    Wang, Jingling
    Yuan, WenXin
    Zhang, WeiPing
    Liu, Zhixing
    Mao, Yi
    CANCER IMAGING, 2024, 24 (01)
  • [5] Volumetric Flow Estimation in a Coronary Artery Phantom Using High-Frame-Rate Contrast-Enhanced Ultrasound, Speckle Decorrelation, and Doppler Flow Direction Detection
    Zhou, Xiaowei
    Toulemonde, Matthieu
    Zhou, Xinhuan
    Hansen-Shearer, Joseph
    Senior, Roxy
    Tang, Meng-Xing
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (11) : 3299 - 3308
  • [6] Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
    Du, Yigang
    Ding, Haiyan
    He, Le
    Yiu, Billy Y. S.
    Deng, Linsong
    Yu, Alfred C. H.
    Zhu, Lei