An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power

被引:1
作者
Yang, Zhi [1 ]
Zhou, Yanwen [1 ,2 ]
Jin, Tianru [1 ]
Li, Jingjing [1 ]
机构
[1] Shenyang Aier Eye Optometry Hosp, Dept Cataract, Shenyang, Peoples R China
[2] 11 Shiyiwei Rd, Shenyang, Liaoning, Peoples R China
关键词
Astigmatism; Barrett; calculation; cataract; Kane; total corneal refractive power; ASTIGMATISM MEASUREMENTS; IMPLANTATION; EYES; REPEATABILITY; INCISIONS; SYSTEM;
D O I
10.4103/ijo.IJO_1539_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate a method using measured values of total corneal refractive power (TCRP) for a manufacturer's online calculator by comparing it with the Barrett toric calculator (BTC) and Kane toric calculator (KTC) combined with simulated keratometry values (SimK). Methods: This was a retrospective case series. Patient records were reviewed to identify the patients who had biometry with the IOL Master 700 and Pentacam recorded before toric IOL implantation and refractive follow-up data after implantation. The predicted error in residual astigmatism was calculated by vector analysis according to the calculation methods and the measurements used. Results: A total of 70 eyes of 56 patients were included. The mean absolute astigmatism prediction errors were 0.6 +/- 0.32, 0.59 +/- 0.35, and 0.61 +/- 0.35 D for the ATC(TCRP), BTCSimK, and KTCSimK calculators, respectively (P = 0.934), and the centroid of the prediction errors were 0.3 D @ 178 degrees, 0.11 D @ 102 degrees, and 0.09 D @ 147 degrees, respectively (P = 0.23). In the with-the-rule subgroup, the centroid of the prediction error was 0.34 D @ 176 degrees for ATC(TCRP) and was the highest among the three calculation methods (P = 0.046). Conclusion: The ATC(TCRP), BTCSimK, and KTCSimK calculators had similar performance with regards to their astigmatism prediction accuracy. The ATC(TCRP) calculator combined with 4.0-mm apex/ring readings of TCRP was slightly intended to result in against-the-rule residual astigmatism.
引用
收藏
页码:541 / 546
页数:6
相关论文
共 27 条
[1]  
Barrett G, 2018, BARRETT TORIC FORMUL
[2]   Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [J].
Chen, Davie ;
Lam, Andrew K. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :448-454
[3]   Accuracy of Total Corneal Power Calculation for Multifocal Toric Intraocular Lens Implantation: Swept-Source OCT-Based Biometer vs Scheimpflug Tomographer [J].
Choi, Ayoung ;
Kwon, Hyunggoo ;
Jeon, Sohee .
JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (10) :686-+
[4]   Comparison of the Kane formula with existing formulas for intraocular lens power selection [J].
Connell, Benjamin J. ;
Kane, Jack X. .
BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01)
[5]   Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power [J].
Davison, James A. ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2015, 9 :1511-1517
[6]   Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses [J].
Fam, Han Bor ;
Lim, Kooi Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2072-2076
[7]   Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation [J].
Ferreira, Tiago B. ;
Ribeiro, Paulo ;
Ribeiro, Filomena J. ;
O'Neill, Joao G. .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (12) :794-801
[8]  
Haigis W, OPTIMIZED IOL CONSTA
[9]   Simulation of toric intraocular lens results: Manual "keratomtry versus dual-zone automated keratometry from an integrated biometer [J].
Hill, Warren ;
Osher, Robert ;
Cooke, David ;
Solomon, Kerry ;
Sandoval, Helga ;
Salas-Cervantes, Rosario ;
Potvin, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (12) :2181-2187
[10]   Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism [J].
Holladay, JT ;
Moran, JR ;
Kezirian, GM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :61-79