Deep Convolutional Neural Network for Dedicated Regions-of-Interest Based Multi-Parameter Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Knee Joint

被引:0
作者
Lu, Xing [1 ]
Ma, Yajun [1 ]
Chang, Eric Y. [1 ,2 ]
Athertya, Jiyo [1 ]
Jang, Hyungseok [1 ]
Jerban, Saeed [1 ]
Covey, Dana C. [3 ]
Bukata, Susan [3 ]
Chung, Christine B. [1 ,2 ]
Du, Jiang [1 ,2 ,4 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, San Diego, CA 92037 USA
[2] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA 92110 USA
[3] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA USA
[4] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92093 USA
来源
JOURNAL OF IMAGING INFORMATICS IN MEDICINE | 2024年 / 37卷 / 05期
基金
美国国家卫生研究院;
关键词
Quantitative MRI; Automated segmentation; DCNN; RMQ-Net; UTE; Knee joint; OA; ARTICULAR-CARTILAGE; SEGMENTATION; CLASSIFICATION; OSTEOARTHRITIS;
D O I
10.1007/s10278-024-01089-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We proposed an end-to-end deep learning convolutional neural network (DCNN) for region-of-interest based multi-parameter quantification (RMQ-Net) to accelerate quantitative ultrashort echo time (UTE) MRI of the knee joint with automatic multi-tissue segmentation and relaxometry mapping. The study involved UTE-based T1 (UTE-T1) and Adiabatic T1 rho (UTE-AdiabT1 rho) mapping of the knee joint of 65 human subjects, including 20 normal controls, 29 with doubtful-minimal osteoarthritis (OA), and 16 with moderate-severe OA. Comparison studies were performed on UTE-T1 and UTE-AdiabT1 rho measurements using 100%, 43%, 26%, and 18% UTE MRI data as the inputs and the effects on the prediction quality of the RMQ-Net. The RMQ-net was modified and retrained accordingly with different combinations of inputs. Both ROI-based and voxel-based Pearson correlation analyses were performed. High Pearson correlation coefficients were achieved between the RMQ-Net predicted UTE-T1 and UTE-AdiabT1 rho results and the ground truth for segmented cartilage with acceleration factors ranging from 2.3 to 5.7. With an acceleration factor of 5.7, the Pearson r-value achieved 0.908 (ROI-based) and 0.945 (voxel-based) for UTE-T1, and 0.733 (ROI-based) and 0.895 (voxel-based) for UTE-AdiabT1 rho, correspondingly. The results demonstrated that RMQ-net can significantly accelerate quantitative UTE imaging with automated segmentation of articular cartilage in the knee joint.
引用
收藏
页码:2126 / 2134
页数:9
相关论文
共 43 条
  • [1] Quantitative metrics in clinical radiology reporting: a snapshot perspective from a single mixed academic-community practice
    Abramson, Richard G.
    Su, Pei-Fang
    Shyr, Yu
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1357 - 1366
  • [2] Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging
    Afsahi, Amir Masoud
    Ma, Yajun
    Jang, Hyungseok
    Jerban, Saeed
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (06) : 1597 - 1612
  • [3] Yet more evidence that osteoarthritis is not a cartilage disease
    Brandt, K. D.
    Radin, E. L.
    Dieppe, P. A.
    van de Putte, L.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 (10) : 1261 - 1264
  • [4] Buckwalter J A, 1995, Clin Symp, V47, P1
  • [5] Multi-task neural networks for joint hippocampus segmentation and clinical score regression
    Cao, Liang
    Li, Long
    Zheng, Jifeng
    Fan, Xin
    Yin, Feng
    Shen, Hui
    Zhang, Jun
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (22) : 29669 - 29686
  • [6] UTE Imaging in the Musculoskeletal System
    Chang, Eric Y.
    Du, Jiang
    Chung, Christine B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 870 - 883
  • [7] Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS)
    Chaudhari, Akshay S.
    Sveinsson, Bragi
    Moran, Catherine J.
    McWalter, Emily J.
    Johnson, Ethan M.
    Zhang, Tao
    Gold, Garry E.
    Hargreaves, Brian A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2136 - 2148
  • [8] Quantitative Magnetic Resonance Imaging UTE-T2*Mapping of Cartilage and Meniscus Healing After Anatomic Anterior Cruciate Ligament Reconstruction
    Chu, Constance R.
    Williams, Ashley A.
    West, Robin V.
    Qian, Yongxian
    Fu, Freddie H.
    Do, Bao H.
    Bruno, Stephen
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (08) : 1847 - 1856
  • [9] Quantitative MRI Musculoskeletal Techniques: An Update
    de Mello, Ricardo
    Ma, Yajun
    Ji, Yang
    Du, Jiang
    Chang, Eric Y.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 524 - 533
  • [10] Optimization of spin-lock times for T1ρ mapping of human knee cartilage with bi- and stretched-exponential models
    de Moura, Hector L.
    Menon, Rajiv G.
    Zibetti, Marcelo V. W.
    Regatte, Ravinder R.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)