A passive dorsiflexing ankle prosthesis to increase minimum foot clearance during swing

被引:2
|
作者
Bartlett, Harrison L. [1 ]
Shepherd, Max K. [2 ,3 ]
Lawson, Brian E. [1 ]
机构
[1] Little Room Innovat LLC, Ann Arbor, MI USA
[2] Northeastern Univ, Dept Mech Engn, Boston, MA 02115 USA
[3] Northeastern Univ, Dept Phys Therapy, Boston, MA 02115 USA
来源
WEARABLE TECHNOLOGIES | 2023年 / 4卷
关键词
Amputation; biomechanics; minimum foot clearance; gait; foot; prosthesis; QUALITY-OF-LIFE; TOE CLEARANCE; BACK-PAIN; LEG-LENGTH; RESIDUAL LIMB; RISK-FACTORS; WALKING; PEOPLE; AMPUTATION; AMPUTEES;
D O I
10.1017/wtc.2023.10
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The biological ankle dorsiflexes several degrees during swing to provide adequate clearance between the foot and ground, but conventional energy storage and return (ESR) prosthetic feet remain in their neutral position, increasing the risk of toe scuffs and tripping. We present a new prosthetic ankle intended to reduce fall risk by dorsiflexing the ankle joint during swing, thereby increasing the minimum clearance between the foot and ground. Unlike previous approaches to providing swing dorsiflexion such as powered ankles or hydraulic systems with dissipative yielding in stance, our ankle device features a spring-loaded linkage that adopts a neutral angle during stance, allowing ESR, but adopts a dorsiflexed angle during swing. The ankle unit was designed, fabricated, and assessed in level ground walking trials on a unilateral transtibial prosthesis user to experimentally validate its stance and swing phase behaviors. The assessment consisted of three conditions: the ankle in an operational configuration, the ankle in a locked configuration (unable to dorsiflex), and the subject's daily use ESR prosthesis. When the ankle was operational, minimum foot clearance (MFC) increased by 13 mm relative to the locked configuration and 15 mm relative to his daily use prosthesis. Stance phase energy return was not significantly impacted in the operational configuration. The increase in MFC provided by the passive dorsiflexing ankle prosthesis may be sufficient to decrease the rate of falls experienced by prosthesis users in the real world.
引用
收藏
页数:19
相关论文
共 32 条
  • [21] Midfoot passive stiffness affects foot and ankle kinematics and kinetics during the propulsive phase of walking
    Magalhaes, Fabricio Anicio
    Fonseca, Sergio Teixeira
    Araujo, Vanessa Lara
    Trede, Renato Guilherme
    Oliveira, Lilian Marques
    Miranda E Castor, Camila Gomes
    Pinto, Rafael Zambelli
    Souza, Thales Rezende
    JOURNAL OF BIOMECHANICS, 2021, 119
  • [22] Continuous relative phases of walking with an articulated passive ankle-foot prosthesis in individuals with a unilateral transfemoral and transtibial amputation: an explorative case-control study
    Lathouwers, Elke
    Baeyens, Jean-Pierre
    Tassignon, Bruno
    Gomez, Felipe
    Cherelle, Pierre
    Meeusen, Romain
    Vanderborght, Bram
    De Pauw, Kevin
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [23] A new measure of trip risk integrating minimum foot clearance and dynamic stability across the swing phase of gait
    Schulz, Brian W.
    JOURNAL OF BIOMECHANICS, 2017, 55 : 107 - 112
  • [24] Soldier-relevant body borne load impacts minimum foot clearance during obstacle negotiation
    Brown, T. N.
    Loverro, K. L.
    Schiffman, J. M.
    APPLIED ERGONOMICS, 2016, 55 : 56 - 62
  • [25] Continuous relative phases of walking with an articulated passive ankle–foot prosthesis in individuals with a unilateral transfemoral and transtibial amputation: an explorative case–control study
    Elke Lathouwers
    Jean-Pierre Baeyens
    Bruno Tassignon
    Felipe Gomez
    Pierre Cherelle
    Romain Meeusen
    Bram Vanderborght
    Kevin De Pauw
    BioMedical Engineering OnLine, 22
  • [26] Design and structural analysis of a passive ankle-foot prosthesis with manually adjustable stiffness and having two degrees of freedom
    Vinay, B. S.
    Thinlay, Tenzin
    Jayswal, Sumit K.
    Pradeep, Sankeerth
    Bais, Manish
    Prasad, Kovvuri Durga
    Singh, Jai Inder Preet
    MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 3496 - 3505
  • [27] Step-to-step transition work during level and inclined walking using passive and powered ankle-foot prostheses
    Esposito, Elizabeth Russell
    Whitehead, Jennifer M. Aldridge
    Wilken, Jason M.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2016, 40 (03) : 311 - 319
  • [28] Does Use of a Powered Ankle-foot Prosthesis Restore Whole-body Angular Momentum During Walking at Different Speeds?
    D'Andrea, Susan
    Wilhelm, Natalie
    Silverman, Anne K.
    Grabowski, Alena M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (10) : 3044 - 3054
  • [29] Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking
    Kim, Myunghee
    Collins, Steven H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
  • [30] Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking
    Myunghee Kim
    Steven H Collins
    Journal of NeuroEngineering and Rehabilitation, 12