Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations

被引:2
作者
Fletcher, Elizabeth M. [1 ]
Ballester, Facundo [2 ,3 ]
Beaulieu, Luc [4 ,5 ,6 ]
Morrison, Hali [7 ,8 ,9 ]
Poher, Audran [4 ,5 ,6 ]
Rivard, Mark J. [10 ,12 ]
Sloboda, Ron S. [11 ]
Vijande, Javier [2 ,3 ,13 ]
Thomson, Rowan M. [1 ,14 ]
机构
[1] Carleton Univ, Phys Dept, Carleton Lab Radiotherapy Phys, Ottawa, ON, Canada
[2] Univ Valencia UV, Dept Fis Atom Mol & Nucl, Burjassot, Spain
[3] Univ Valencia UV, Unidad Mixta Invest Radiofis Instrumentac Nucl Med, Inst Invest Sanitaria Fe IIS La Fe, Burjassot, Spain
[4] CHU Quebec, Ctr Rech CHU Quebec, Serv Phys Med & Axe Oncol, Quebec City, PQ, Canada
[5] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[6] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[7] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[8] Univ Calgary, Dept Phys & Astron, Calgary, AB, Canada
[9] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB, Canada
[10] Brown Univ, Warren Alpert Med Sch, Dept Radiat Oncol, Providence, RI USA
[11] Cross Canc Inst, Dept Med Phys, Edmonton, AB, Canada
[12] Univ Alberta, Dept Oncol, Edmonton, AB, Canada
[13] IF UV CSIC, Inst Fis Corpuscular, Burjassot, Spain
[14] Carleton Univ, Phys Dept, Carleton Lab Radiotherapy Phys, Ottawa, ON K1S5 B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Monte Carlo; ocular brachytherapy; treatment planning; COLLAPSED CONE SUPERPOSITION; MONTE-CARLO-SIMULATION; NUCLEAR-DATA; I-125; AAPM; PD-103; TOPAS; RECOMMENDATIONS; ALGORITHM; ENGINE;
D O I
10.1002/mp.16721
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeA joint Working Group of the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) was created to aid in the transition from the AAPM TG-43 dose calculation formalism, the current standard, to model-based dose calculations. This work establishes the first test cases for low-energy photon-emitting brachytherapy using model-based dose calculation algorithms (MBDCAs).Acquisition and Validation MethodsFive test cases are developed: (1) a single model 6711 125I brachytherapy seed in water, 13 seeds (2) individually and (3) in combination in water, (4) the full Collaborative Ocular Melanoma Study (COMS) 16-mm eye plaque in water, and (5) the full plaque in a realistic eye phantom. Calculations are done with four Monte Carlo (MC) codes and a research version of a commercial treatment planning system (TPS). For all test cases, local agreement of MC codes was within & SIM;2.5% and global agreement was & SIM;2% (4% for test case 5). MC agreement was within expected uncertainties. Local agreement of TPS with MC was within 5% for test case 1 and & SIM;20% for test cases 4 and 5, and global agreement was within 0.4% for test case 1 and 10% for test cases 4 and 5.Data Format and Usage NotesDose distributions for each set of MC and TPS calculations are available online () along with input files and all other information necessary to repeat the calculations.Potential ApplicationsThese data can be used to support commissioning of MBDCAs for low-energy brachytherapy as recommended by TGs 186 and 221 and AAPM Report 372. This work additionally lays out a sample framework for the development of test cases that can be extended to other applications beyond eye plaque brachytherapy.
引用
收藏
页码:694 / 706
页数:13
相关论文
共 56 条
  • [11] ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data
    Chadwick, M. B.
    Herman, M.
    Oblozinsky, P.
    Dunn, M. E.
    Danon, Y.
    Kahler, A. C.
    Smith, D. L.
    Pritychenko, B.
    Arbanas, G.
    Arcilla, R.
    Brewer, R.
    Brown, D. A.
    Capote, R.
    Carlson, A. D.
    Cho, Y. S.
    Derrien, H.
    Guber, K.
    Hale, G. M.
    Hoblit, S.
    Holloway, S.
    Johnson, T. D.
    Kawano, T.
    Kiedrowski, B. C.
    Kim, H.
    Kunieda, S.
    Larson, N. M.
    Leal, L.
    Lestone, J. P.
    Little, R. C.
    McCutchan, E. A.
    MacFarlane, R. E.
    MacInnes, M.
    Mattoon, C. M.
    McKnight, R. D.
    Mughabghab, S. F.
    Nobre, G. P. A.
    Palmiotti, G.
    Palumbo, A.
    Pigni, M. T.
    Pronyaev, V. G.
    Sayer, R. O.
    Sonzogni, A. A.
    Summers, N. C.
    Talou, P.
    Thompson, I. J.
    Trkov, A.
    Vogt, R. L.
    van der Marck, S. C.
    Wallner, A.
    White, M. C.
    [J]. NUCLEAR DATA SHEETS, 2011, 112 (12) : 2887 - 2996
  • [12] egs_brachy: a versatile and fast Monte Carlo code for brachytherapy
    Chamberland, Marc J. P.
    Taylor, Randle E. P.
    Rogers, D. W. O.
    Thomson, Rowan M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : 8214 - 8231
  • [13] Dosimetry of 125I and 103Pd COMS eye plaques for intraocular tumors: Report of Task Group 129 by the AAPM and ABS
    Chiu-Tsao, Sou-Tung
    Astrahan, Melvin A.
    Finger, Paul T.
    Followill, David S.
    Meigooni, Ali S.
    Melhus, Christopher S.
    Mourtada, Firas
    Napolitano, Mary E.
    Nath, Ravinder
    Rivard, Mark J.
    Rogers, D. W. O.
    Thomson, Rowan M.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6161 - 6184
  • [14] Cullen D.E., 1997, EPDL97: the Evaluated Photon Data Library, '97 Few/on.UCRL-50400, Volume 6
  • [15] A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO
    DeWerd, Larry A.
    Ibbott, Geoffrey S.
    Meigooni, Ali S.
    Mitch, Michael G.
    Rivard, Mark J.
    Stump, Kurt E.
    Thomadsen, Bruce R.
    Venselaar, Jack L. M.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 782 - 801
  • [16] Monte Carlo and experimental dosimetry of an 125I brachytherapy seed
    Dolan, James
    Li, Zuofeng
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2006, 33 (12) : 4675 - 4684
  • [17] The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research
    Faddegon, Bruce
    Ramos-Mendez, Jose
    Schuemann, Jan
    McNamara, Aimee
    Shin, Jungwook
    Perl, Joseph
    Paganetti, Harald
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 72 : 114 - 121
  • [18] Risk Factors for Radiation Maculopathy after Ophthalmic Plaque Radiation for Choroidal Melanoma
    Finger, Paul T.
    Chin, Kimberly J.
    Yu, Guo-Pei
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) : 608 - 615
  • [19] Tumour location affects the incidence of cataract and retinopathy after ophthalmic plaque radiation therapy
    Finger, PT
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (09) : 1068 - 1070
  • [20] Nuclear Data Sheets for A=125
    Katakura, J.
    [J]. NUCLEAR DATA SHEETS, 2011, 112 (03) : 495 - 705