Data window selection for removal of decaying DC component in current phasor estimation for distance protection

被引:0
|
作者
Hajimahani, Mohammad Kazem [1 ]
Zamani, Hamid [1 ]
Jamali, Sadegh [1 ]
机构
[1] Iran Univ Sci & Technol, Sch Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran, Iran
关键词
Distance protection; Decaying DC current; Transmission line; Data window; OFFSET; ALGORITHM; ACCURATE; SIGNAL;
D O I
10.1016/j.epsr.2023.109546
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In distance protection, the fault current signal is usually distorted by the decaying direct current (DC) and harmonics preventing accurate and fast estimation of the fault current phasor. This paper presents a method based on the carefully selected data windows and least square (LSQ) method to improve the performance of the current phasor estimation. The method comprises a short and variable data window for fast operation of distance relay for close faults and a fixed data window for the accurate operation of the relay for faults close to the boundary of Zone 1. The short and variable data window can achieve high speed in the phasor estimation in a quarter of cycle, whereas the second algorithm uses a fixed data window with an excellent frequency response to increase the accuracy of the phasor estimation. The proposed method is first tested using mathematical formulation under different conditions such as different characteristics of the DC component, noise, harmonics and frequency deviation. Then the method is tested by more realistic samples taken from a simulated transmission system under different fault conditions for flexibility, speed and accuracy. All the test results validate the aforementioned features of the proposed algorithms.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Distance Protection Using a Novel Phasor Estimation Algorithm Based on Wavelet Transform
    Silva, K. M.
    Neves, W. L. A.
    Souza, B. A.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4131 - 4138
  • [32] Novel Method for Decaying DC Component Removal Based on Solving the Differential Equations
    Haji-Mohammadi, Amir
    Sanaye-Pasand, Majid
    Ahmadi, Seyed-Alireza
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 693 - 704
  • [33] DFT-Based Phasor Estimation for Removal of the Effect of Multiple DC Components
    Hwang, Jin Kwon
    Song, Chul Ki
    Jeong, Moon Gyu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 2901 - 2909
  • [34] Hybrid approach for immunisation of DFT-based phasor estimation method against decaying DC components
    Allahbakhshi, Mehdi
    Tajdinian, Mohsen
    Seifi, Ali Reza
    Jahromi, Mehdi Zareian
    Bagheri, Alireza
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (02) : 238 - 246
  • [35] Research on the Component Current and Voltage Phasor Diagram at Fault Point in Microcomputer Protection
    Wang Jihong
    Wu Shijing
    Zhang Dawei
    Luo Xiaohua
    Zhang Ming
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [36] Algorithm for phasor estimation during current transformer saturation and/or DC component presence: definition and application in arc detection on overhead lines
    Belcevic, Nenad M.
    Stojanovic, Zoran N.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (07) : 1378 - 1388
  • [37] Strengths and limitations of a new phasor estimation technique to reduce CCVT impact in distance protection
    Pajuelo, E.
    Ramakrishna, G.
    Sachdev, M. S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (04) : 417 - 425
  • [38] New modified DFT-Prony-based algorithms for removal of decaying DC components from fundamental phasor estimates
    Dimitrije Rozgić
    Predrag B. Petrović
    Electrical Engineering, 2022, 104 : 3265 - 3279
  • [39] New modified DFT-Prony-based algorithms for removal of decaying DC components from fundamental phasor estimates
    Rozgic, Dimitrije
    Petrovic, Predrag B.
    ELECTRICAL ENGINEERING, 2022, 104 (05) : 3265 - 3279
  • [40] Assessment of DC offset in fault current signal for accurate phasor estimation considering current transformer response
    Achlerkar, Pankaj D.
    Panigrahi, Bijaya Ketan
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (03) : 403 - 408