Micro-Sized Pinhole Inspection with Segmented Time Reversal and High-Order Modes Cluster Lamb Waves Based on EMATs

被引:1
作者
Zhou, Jinjie [1 ]
Hu, Yang [1 ]
Li, Xiang [2 ]
Zheng, Yang [3 ]
Yang, Sanhu [1 ]
Liu, Yao [1 ]
机构
[1] North Univ China, Sch Mech Engn, Taiyuan 030051, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Aeronaut & Astronaut, Chengdu 611731, Peoples R China
[3] China Special Equipment Inspect & Res Inst, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Pinhole corrosion; High-order modes cluster; Lamb waves; Segmented time reversal inspection; Electromagnetic acoustic transducer; COMPOSITE PLATES; GENERATION; DEFECT; HOMC;
D O I
10.1186/s10033-023-00853-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pinhole corrosion is difficult to discover through conventional ultrasonic guided waves inspection, particularly for micro-sized pinholes less than 1 mm in diameter. This study proposes a new micro-sized pinhole inspection method based on segmented time reversal (STR) and high-order modes cluster (HOMC) Lamb waves. First, the principle of defect echo enhancement using STR is introduced. Conventional and STR inspection experiments were conducted on aluminum plates with a thickness of 3 mm and defects with different diameters and depths. The parameters of the segment window are discussed in detail. The results indicate that the proposed method had an amplitude four times larger than of conventional ultrasonic guided waves inspection method for pinhole defect detection and could detect micro-sized pinhole defects as small as 0.5 mm in diameter and 0.5 mm in depth. Moreover, the segment window location and width (5-10 times width of the conventional excitation signal) did not affect the detection sensitivity. The combination of low-power and STR is more conducive to detection in different environments, indicating the robustness of the proposed method. Compared with conventional ultrasonic guided wave inspection methods, the proposed method can detect much smaller defect echoes usually obscured by noise that are difficult to detect with a lower excitation power and thus this study would be a good reference for pinhole defect detection.
引用
收藏
页数:13
相关论文
共 33 条
[1]   Evaluation of the sensitivity of higher order modes cluster (HOMC) guided waves to plate defects [J].
Abbasi, Zahra ;
Honarvar, Farhang .
APPLIED ACOUSTICS, 2022, 187
[2]   Effects of adhesive, host plate, transducer and excitation parameters on time reversibility of ultrasonic Lamb waves [J].
Agrahari, J. K. ;
Kapuria, S. .
ULTRASONICS, 2016, 70 :147-157
[3]   Lamb wave inspection using piezoelectric diaphragms: An initial feasibility study [J].
Campeiro, Leandro Melo ;
Budoya, Danilo Ecidir ;
Baptista, Fabricio Guimaraes .
SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
[4]   Ellipse of uncertainty based algorithm for quantitative evaluation of defect localization using Lamb waves [J].
Chen, Honglei ;
Xu, Kailiang ;
Liu, Zenghua ;
Ta, Dean .
ULTRASONICS, 2022, 125
[5]  
[邓菲 Deng Fei], 2011, [机械工程学报, Chinese Journal of Mechanical Engineering], V47, P17
[6]  
[邓菲 Deng Fei], 2010, [机械工程学报, Chinese Journal of Mechanical Engineering], V46, P18
[7]   Ultrasonic time-reversal-based super resolution imaging for defect localization and characterization [J].
Fan, Chengguang ;
Yu, Sunquan ;
Gao, Bin ;
Zhao, Yong ;
Yang, Lei .
NDT & E INTERNATIONAL, 2022, 131
[8]   Ultrasonic multi-frequency time-reversal-based imaging of extended targets [J].
Fan, Chengguang ;
Yang, Lei ;
Zhao, Yong .
NDT & E INTERNATIONAL, 2020, 113
[9]   Time reversal technique for health monitoring of metallic structure using Lamb waves [J].
Gangadharan, R. ;
Murthy, C. R. L. ;
Gopalakrishnan, S. ;
Bhat, M. R. .
ULTRASONICS, 2009, 49 (08) :696-705
[10]  
[关立强 Guan Liqiang], 2019, [南京大学学报. 自然科学版, Journal of Nanjing University. Natural Sciences], V55, P191