Influence of Anodizing Conditions on Biotribological and Micromechanical Properties of Ti-13Zr-13Nb Alloy

被引:6
作者
Stroz, Agnieszka [1 ]
Maszybrocka, Joanna [1 ]
Goryczka, Tomasz [1 ]
Dudek, Karolina [2 ]
Osak, Patrycja [1 ]
Losiewicz, Bozena [1 ]
机构
[1] Univ Silesia Katowice, Inst Mat Engn, Fac Sci & Technol, 75 Pulku Piechoty 1A, PL-41500 Chorzow, Poland
[2] Lukasiewicz Res Network, Inst Ceram & Bldg Mat, Refractory Mat Ctr, Toszecka 99, PL-44100 Gliwice, Poland
关键词
anodizing; biomaterials; biotribology; oxide nanotubes; Ti-13Zr-13Nb alloy; NANOTUBULAR OXIDE LAYERS; TRIBOLOGICAL PROPERTIES; TI13NB13ZR ALLOY; TI13ZR13NB ALLOY; ELECTROCHEMICAL FORMATION; TIO2; NANOTUBES; MICROSTRUCTURE; COATINGS; BEHAVIOR;
D O I
10.3390/ma16031237
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The biomedical Ti-13Zr-13Nb bi-phase (alpha + beta) alloy for long-term applications in implantology has recently been developed. The porous oxide nanotubes' (ONTs) layers of various geometries and lengths on the Ti-13Zr-13Nb alloy surface can be produced by anodizing to improve osseointegration. This work was aimed at how anodizing conditions determinatine the micromechanical and biotribological properties of the Ti-13Zr-13Nb alloy. First-generation (1G), second-generation (2G), and third-generation (3G) ONT layers were produced on the Ti-13Zr-13Nb alloy surface by anodizing. The microstructure was characterized using SEM. Micromechanical properties were investigated by the Vickers microhardness test under variable loads. Biotribological properties were examined in Ringer's solution in a reciprocating motion in the ball-on-flat system. The 2D roughness profiles method was used to assess the wear tracks of the tested materials. Wear scars' analysis of the ZrO2 ball was performed using optical microscopy. It was found that the composition of the electrolyte with the presence of fluoride ions was an essential factor influencing the micromechanical and biotribological properties of the obtained ONT layers. The three-body abrasion wear mechanism was proposed to explain the biotribological wear in Ringer's solution for the Ti-13Zr-13Nb alloy before and after anodizing.
引用
收藏
页数:17
相关论文
共 47 条
  • [1] Alkali-Treated Titanium Coated with a Polyurethane, Magnesium and Hydroxyapatite Composite for Bone Tissue Engineering
    Agour, Mahmoud
    Abdal-hay, Abdalla
    Hassan, Mohamed K.
    Bartnikowski, Michal
    Ivanovski, Saso
    [J]. NANOMATERIALS, 2021, 11 (05)
  • [2] Interfacial Barrier Layer Properties of Three Generations of TiO2 Nanotube Arrays
    Ainouche, L.
    Hamadou, L.
    Kadri, A.
    Benbrahim, N.
    Bradai, D.
    [J]. ELECTROCHIMICA ACTA, 2014, 133 : 597 - 609
  • [3] Biomedical materials: A review of titanium based alloys
    Anene, F. A.
    Aiza Jaafar, C. N.
    Zainol, I
    Azmah Hanim, M. A.
    Suraya, M. T.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (19) : 3792 - 3805
  • [4] Mechanical Properties, Corrosion Resistance and Bioactivity of Oxide Layers Formed by Isothermal Oxidation of Ti-6Al-7Nb Alloy
    Aniolek, Krzysztof
    Losiewicz, Bozena
    Kubisztal, Julian
    Osak, Patrycja
    Stroz, Agnieszka
    Barylski, Adrian
    Kaptacz, Slawomir
    [J]. COATINGS, 2021, 11 (05)
  • [5] [Anonymous], 2021, F1713082021E1 ASTM
  • [6] [Anonymous], 2018, 6507-2:2018
  • [7] [Anonymous], 2018, 650712018 ISO
  • [8] [Anonymous], 2018, TITANIUM MED DENT AP
  • [9] Mechanical Characterization and In Vitro Assay of Biocompatible Titanium Alloys
    Baltatu, Iustinian
    Sandu, Andrei Victor
    Vlad, Maria Daniela
    Spataru, Mihaela Claudia
    Vizureanu, Petrica
    Baltatu, Madalina Simona
    [J]. MICROMACHINES, 2022, 13 (03)
  • [10] Preliminary Tests for Ti-Mo-Zr-Ta Alloys as Potential Biomaterials
    Baltatu, M. S.
    Vizureanu, P.
    Balan, T.
    Lohan, M.
    Tugui, C. A.
    [J]. EUROINVENT ICIR 2018, 2018, 374