Comparision of Cardiac Output Measured by Transthoracic Echocardiography with Continuous Cardiac Output Measured by Pressure Recording Analytical Method

被引:0
|
作者
Madhuri, M. Roja [1 ]
Singh, Naveen G. [1 ]
Nagaraja, P. S. [1 ]
Pranathi, E. [1 ]
Shankar, Prabhu C. G. [1 ]
Satish, N. [1 ]
Prabhakar, V [1 ]
Gupta, Apoorva [2 ]
机构
[1] SJICR, Dept Anaesthesisiol, Bengaluru 560069, Karnataka, India
[2] Oxford Med Coll & Hosp, Bangalore, Karnataka, India
关键词
Cardiac output; pressure recording analytical method; transthoracic echocardiography; ANALYTICAL METHOD PRAM;
D O I
10.4103/aca.aca_41_22
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Low cardiac output is a common complication following cardiac surgery and it is associated with higher mortality in the pediatric population. A gold standard method for cardiac output (CO) monitoring in the pediatric population is lacking. The present study was conducted to validate cardiac output and cardiac index measured by transthoracic echocardiography and Pressure recording analytical method, a continuous pulse contour method, MostCare(Up) in postoperative pediatric cardiac surgical patients. Materials and Methods: This was a prospective observational clinical study conducted at a tertiary care hospital. A total of 23 pediatric patients weighed between 2 and 20 kg who had undergone elective cardiac surgery were included in the study. Results: Spearman's correlation coefficient of CO between transthoracic echocardiography (TTE) and Pressure Recording Analytical Method (PRAM) showed of positive correlation (r = 0.69, 95% Confidence interval 0.59-0.77, P < 0.0001) Linear regression equations for CO between TTE and PRAM were y = 0.55 + 0.88x (R-2 = 0.46, P < 0.0001). (y = PRAM, x = TTE), respectively. Bland- Altman plot for CO between TTE and PRAM showed a bias of -0.397 with limits of the agreement being -2.01 to 1.22. Polar plot analysis showed an angular bias of 6.55 degrees with radial limits of the agreement being -21.46 to 34.58 for CO and angular bias of 6.22 degrees with radial limits of the agreement being -22.4 to 34.84 for CI. Conclusion: PRAM has shown good trending ability for cardiac output. However, values measured by PRAM are not interchangeable with the values measured by transthoracic echocardiography.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [1] STROKE VOLUME AND CARDIAC OUTPUT MEASURED BY ECHOCARDIOGRAPHY
    PENNOCK, R
    KINGSLEY, B
    KAWAI, N
    KIMBIRIS, D
    SEGAL, BL
    AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (01): : 121 - &
  • [2] Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    Giomarelli, P
    Biagioli, B
    Scolletta, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 515 - 520
  • [3] MEASUREMENT OF CARDIAC OUTPUT IN CHILDREN BY PRESSURE RECORDING ANALYTICAL METHOD
    Urbano, J.
    Lopez, J.
    Gonzalez, R.
    Solana, M. J.
    Fernandez, S. N.
    Garcia, M.
    Lopez-Herce, J.
    INTENSIVE CARE MEDICINE, 2013, 39 : S50 - S50
  • [4] Measurement of Cardiac Output in Children by Pressure-Recording Analytical Method
    Javier Urbano
    Jorge López
    Rafael González
    María José Solana
    Sarah N. Fernández
    José M. Bellón
    Jesús López-Herce
    Pediatric Cardiology, 2015, 36 : 358 - 364
  • [5] Measurement of Cardiac Output in Children by Pressure-Recording Analytical Method
    Urbano, Javier
    Lopez, Jorge
    Gonzalez, Rafael
    Jose Solana, Maria
    Fernandez, Sarah N.
    Bellon, Jose M.
    Lopez-Herce, Jesus
    PEDIATRIC CARDIOLOGY, 2015, 36 (02) : 358 - 364
  • [6] Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study
    Aslan, Nagehan
    Yildizdas, Dincer
    Horoz, Ozden Ozgur
    Coban, Yasemin
    Demir, Fadli
    Erdem, Sevcan
    Sertdemir, Yasar
    ITALIAN JOURNAL OF PEDIATRICS, 2020, 46 (01)
  • [7] Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study
    Nagehan Aslan
    Dincer Yildizdas
    Ozden Ozgur Horoz
    Yasemin Coban
    Fadli Demir
    Sevcan Erdem
    Yasar Sertdemir
    Italian Journal of Pediatrics, 46
  • [8] The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography
    Fischer, Marc-Olivier
    Balaire, Xavier
    de Kergal, Charles Le Mauff
    Boisselier, Clement
    Gerard, Jean-Louis
    Hanouz, Jean-Luc
    Fellahi, Jean-Luc
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (01): : 19 - 26
  • [9] COMPARISON OF CARDIAC-OUTPUT MEASURED WITH CONTINUOUS THERMODILUTION AND CARDIAC-OUTPUT CALCULATED WITH THE FICKS PRINCIPLE
    BIZOUARN, P
    BLANLOEIL, Y
    PINAUD, M
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1994, 13 (05): : 685 - 689
  • [10] CARDIAC OUTPUT MEASURED BY THE INJECTION METHOD WITH USE OF RADIOACTIVE MATERIAL AND CONTINUOUS RECORDING - RESULTS OF CIRCULATION MODEL STUDIES
    CRANE, MG
    ADAMS, R
    WOODWARD, I
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1956, 47 (05): : 802 - 810