Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana

被引:1
作者
Ohene-Botwe, Benard [1 ,2 ]
Anim-Sampong, Samuel [2 ]
Nkansah, Josephine [2 ]
机构
[1] City Univ London, Sch Hlth & Psychol Sci, Dept Midwifery & Radiog, Northampton Sq, London EC1V 0HB, England
[2] Univ Ghana, Dept Radiog, Box KB 143, Accra, Ghana
关键词
computed tomography; dose index; size-specific dose estimate; antero-posterior diameter; lateral diameter; effective diameter; CT;
D O I
10.1088/1361-6498/acb5aa
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study determined the size-specific dose estimate (SSDE) of computed tomography (CT) examinations and derived mathematical expressions for dose output estimation and optimization in a teaching hospital in Ghana. Demographic and scanner output indices, including CT dose index (CTDIvol) and dose length product for adult head, chest and abdominopelvic (ABP) CT examinations carried out at the hospital from 2018 to 2020, were retrieved from the picture archiving and communication system of the CT scanner machine. Other indices such as the antero-posterior diameter (D (AP)), lateral diameter (D (L)) and diagonal diameter (D (dia)) of the patients' bodies were measured on the mid-slice axial image using a digital caliper. The effective diameter (D (eff)) was then calculated as the square root of the product of the D (AP) and D (L). The SSDEs were calculated as the product of the CTDIvol and the size-specific conversion factors obtained from Report 204 of the American Association of Physicists in Medicine. Regression analyses were performed to find the relationship between SSDE and the various parameters to derive mathematical equations for the dose estimations. There were more female samples (n= 468, 56.3%) than male samples (n = 364, 43.7%) for each CT procedure. The SSDEs and size-specific diagnostic reference levels (SSDRLs) were: head (83.9 mGy; 86.9 mGy), chest (8.1 mGy; 8.7 mGy) and ABP (8.4 mGy; 9.2 mGy). The variations between CTDIvol and SSDEs for head (2.50%), chest (25.9%), and ABP (26.2%) showed an underestimation of radiation dose to patients, especially in chest and ABP examinations, if CTDIvol is used to report patient doses. The SSDEs of the chest and ABP CT examinations showed linear correlations with the CTDIvol. The estimated values could be used to optimize radiation doses in the CT facility. The SSDE and SSDRLs for head, chest and ABP CT examinations have been developed at a teaching hospital in Ghana. The SSDEs of chest and ABP examinations showed linear correlations with the CTDIvol and hence can be calculated using the mathematically derived equations in the study.
引用
收藏
页数:10
相关论文
共 22 条
[1]  
Adejoh T., 2015, HEALTH-LONDON, V7, P915, DOI [10.4236/health.2015.78108, DOI 10.4236/HEALTH.2015.78108]
[2]  
American Association of Physicists in Medicine, 2011, Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations (Task Group 204)
[3]  
Anim-Sampong S., 2016, SAFETY HEALTH, V2, P1, DOI [10.1186/s40886-016-0019-4, DOI 10.1186/S40886-016-0019-4]
[4]   Dose optimization of adult head computed tomography examination in an academic hospital in Ghana [J].
Anim-Sampong, Samuel ;
Ohene-Botwe, Benard ;
Adom, Esther Boatemaa ;
Tagoe, Samuel Nii Adu .
RADIATION PHYSICS AND CHEMISTRY, 2023, 205
[5]   CT dosimetry: comparison of measurement techniques and devices [J].
Bauhs, John A. ;
Vrieze, Thomas J. ;
Primak, Andrew N. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2008, 28 (01) :245-253
[6]   An Investigation into the Infrastructure and Management of Computerized Tomography Units in Ghana [J].
Botwe, Benard ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (01) :165-172
[7]   Variability of redundant scan coverages along the Z-axis and dose implications for common computed tomography examinations [J].
Botwe, Benard Ohene ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (01) :113-122
[8]   National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana [J].
Botwe, Benard Ohene ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine ;
Rolstadaas, Linn ;
Goa, Pal Erik .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 :274-284
[9]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[10]   PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATES [J].
Choudhary, Neha ;
Rana, Bhupendra Singh ;
Shukla, Arvind ;
Oinam, Arun Singh ;
Singh, Narinder Paul ;
Kumar, Sanjeev .
RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) :256-262