Collaborative Study to Establish National Reference Standards for Anti-HIV-1 Antibody

被引:0
作者
Huh, Hee Jin [1 ,6 ]
Kim, Soo-Kyung [2 ]
Chung, Jae-Woo [1 ]
Yoo, Soo Jin [3 ]
Roh, Kyoung Ho [4 ]
Chae, Seok Lae [1 ]
Cha, Young Joo [5 ]
机构
[1] Dongguk Univ, Ilsan Hosp, Dept Lab Med, Goyang, South Korea
[2] Ewha Womans Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[3] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Lab Med, Seoul, South Korea
[4] Natl Hlth Insurance Serv Ilsan Hosp, Dept Lab Med, Goyang, South Korea
[5] Inst Pasteur Korea, Lab Med, Biobank Team, Seongnam, South Korea
[6] Dongguk Univ, Ilsan Hosp, Dept Lab Med, 27 Dongguk Ro, Goyang 10326, Guam, South Korea
关键词
Anti-HIV-1; antibody; HIV; Reference standard; HIV-1;
D O I
10.3343/alm.2023.43.3.273
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: National reference standards for anti-HIV-1 antibody are needed to evaluate the performance and maintain the quality control of anti-HIV-1 antibody assays. The aim of this study was to prepare a mixed-titer performance panel and assess its suitability as a national reference standard for anti-HIV-1 antibody according to stability, collaboration, and other studies.Methods: Nineteen serum samples from different HIV patients were obtained, along with 15 units of fresh frozen plasma samples with negative anti-HIV-1 antibody results. Ten anti -HIV-1 antibody-positive candidate standards and two negative candidate standards were prepared based on the reactivity in the Alinity i HIV Ag/Ab combo assay (Abbott Laborato-ries, Wiesbaden, Germany). A collaborative study was conducted across eight laboratories using five anti-HIV-1 antibody assays. Real-time and accelerated stability were evaluated to assess the long-term stability.Results: In the collaborative study, results of all five anti-HIV-1 antibody assays were posi-tive for all 10 candidate standards prepared using HIV patient samples. The CV of each as-say for every candidate standard was within 10%, except for one assay result. No real-time and accelerated stability change trend was observed at -70 degrees C or -20 degrees C, supporting that the reference standards were maintained in a stable state at -70 degrees C for long-term storage. Conclusions: The overall results suggest that the 12 candidate standards could serve as national reference standards for anti-HIV-1 antibody.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 15 条
[1]   Defibrination of blood plasma for use in serological tests for syphilis [J].
Castro, AR ;
Kikkert, SE ;
Fears, MB ;
Pope, V .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2002, 9 (06) :1376-1378
[2]  
CLSI, 2009, CLSI Document EP25-A
[3]  
ISO, 2017, REF MAT GUID CHAR AS
[4]  
Korea Disease Control and Prevention Agency, 2020, ANN REP NOT HIV AIDS
[5]  
Korean Association of External Quality Assessment Service, 2021, ANN REP EXT QUAL ASS
[6]  
Korean Ministry of Food and Drug Safety, 2022, GUID MIN FOOD DRUG S
[7]  
nifds, LIST MINISTRY FOOD D
[8]   Stability evaluation of national reference standards for blood products in Korea [J].
Park T.J. ;
Choi C.W. ;
Oh H.K. ;
Kim J.O. ;
Kim B.K. ;
Kang H.K. ;
Kwon E.J. ;
Gweon E.J. ;
Park S.J. ;
Kang H.I. ;
Jung K.K. ;
Park S.M. ;
Kim J.H. ;
Han K.W. ;
Jeong J.Y. .
Toxicological Research, 2017, 33 (3) :225-231
[9]  
Park Y, 2022, ANN LAB MED, V42, P447
[10]  
Stone M, 2018, J CLIN MICROBIOL, V56, DOI [10.1128/JCM.02045-17, 10.1128/jcm.02045-17]