A Comparison of Proximal and Tracheal Airway Pressures During Pressure Controlled Ventilation

被引:0
作者
Zander, Mark O. [1 ]
Stankovic, Nikola [3 ]
Meboldt, Mirko [1 ]
Erb, Thomas O. [3 ]
Hammer, Juerg [4 ]
Daners, Marianne Schmid [2 ]
机构
[1] Swiss Fed Inst Technol, Prod Dev Grp Zurich, Dept Mech & Proc Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Dynam Syst & Control, Dept Mech & Proc Engn, Zurich, Switzerland
[3] Univ Basel, Univ Childrens Hosp Basel, Dept Anesthesiol, Basel, Switzerland
[4] Univ Basel, Univ Childrens Hosp Basel, Div Resp & Crit Care Med, Basel, Switzerland
关键词
invasive ventilation; pressure-controlled ventilation; intratracheal pressure; respiratory system compliance; intratracheal pressure sensor; mechanical lung simulator; INTRATRACHEAL PRESSURE; SYSTEM; WORK; LUNG; RESISTANCE;
D O I
10.4187/respcare.10539
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Airway pressure is usually measured by sensors placed in the ventilator or on the ventilator side of the endotracheal tube (ETT), at the Y-piece. These remote measurements serve as a surrogate for the tracheal or alveolar pressure. Tracheal pressure can only be predicted correctly by using a model that incorporates the pressure at the remote location, the flow through the ETT, and the resistance of the ETT if the latter is a predictable function of Y-piece flow. However, this is not consistently appropriate, and accuracy of prediction is hampered. METHODS: This in vitro study systematically examined the ventilator pressure in dependence of compliance of the respiratory system (CRS), inspiratory time, and expiratory time during pressure-controlled ventilation by using a small intratracheal pressure sensor and a mechanical lung simulator. Pressures were measured simultaneously at the ventilator outlet, at the Y-piece, and in the trachea during pressure-controlled ventilation with a peak inspiratory pressure of 20 cm H2O and a PEEP of 5 cm H-2 O while changing CRS (10, 30, 60, 90, and 100 mL/cm H2O) and varying inspiratory time and expiratory time. RESULTS: Tracheal pressures were always lower (maximum 8 cm H2O during inspiration) or higher (maximum 4 cm H2O during expiration) than the pressures measured proximal to the ETT if zero-flow conditions were not achieved at the end of the breathing cycles. CONCLUSIONS: Dependent on CRS and the breathing cycle, tracheal pressures deviated from those measured proximal to the ETT under non-zero-flow conditions. Intratracheal pressure and pressure curve dynamics can differ greatly from the ventilator pressure, depending on the ventilator setting and the CRS. The small pressure sensor may be used as a measurement method of tracheal pressure via integration onto an ETT.
引用
收藏
页码:1639 / 1645
页数:7
相关论文
共 33 条
[1]   Clinical management of pressure control ventilation: An algorithmic method of patient ventilatory management to address "forgotten but important variables" [J].
Ashworth, Lonny ;
Norisue, Yasuhiro ;
Koster, Megan ;
Anderson, Jeff ;
Takada, Junko ;
Ebisu, Hatsuyo .
JOURNAL OF CRITICAL CARE, 2018, 43 :169-182
[2]   Tracheal pressure control provides automatic and variable inspiratory pressure assist to decrease the imposed resistive work of breathing [J].
Banner, MJ ;
Blanch, PB ;
Gabrielli, A .
CRITICAL CARE MEDICINE, 2002, 30 (05) :1106-1111
[3]   Accuracy of the end-expiratory lung volume measured by the modified nitrogen washout/washin technique: a bench study [J].
Berger-Estilita, Joana ;
Haenggi, Matthias ;
Ott, Daniel ;
Berger, David .
JOURNAL OF TRANSLATIONAL MEDICINE, 2021, 19 (01)
[4]  
Crooke PS, 2003, MATH COMPUT MODEL, V38, P495, DOI [10.1016/S0895-7177(03)90021-5, 10.1016/S0895-7177(03)00245-0]
[5]   A FIBER OPTICS SYSTEM FOR THE EVALUATION OF AIRWAY PRESSURE IN MECHANICALLY VENTILATED PATIENTS [J].
DEBLASI, RA ;
CONTI, G ;
ANTONELLI, M ;
BUFI, M ;
GASPARETTO, A .
INTENSIVE CARE MEDICINE, 1992, 18 (07) :405-409
[6]   Rohrer's constant, K2, as a factor of determining inspiratory resistance of common adult endotracheal tubes [J].
Flevari, A. G. ;
Maniatis, N. ;
Kremiotis, T. E. ;
Siempos, I. ;
Betrosian, A. P. ;
Roussos, C. ;
Douzinas, E. ;
Armaganidis, A. .
ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (03) :410-417
[7]   Medical-literary Anthology The implausible doctor [J].
Gomez de la Serna, Ramon .
PANACEA-BOLETIN DE MEDICINA Y TRADUCCION, 2005, 6 (20) :175-178
[8]   CONTINUOUS CALCULATION OF INTRATRACHEAL PRESSURE IN TRACHEALLY INTUBATED PATIENTS [J].
GUTTMANN, J ;
EBERHARD, L ;
FABRY, B ;
BERTSCHMANN, W ;
WOLFF, G .
ANESTHESIOLOGY, 1993, 79 (03) :503-513
[9]   Automatic tube compensation (ATC) [J].
Guttmann, J ;
Haberthür, C ;
Stocker, R ;
Lichtwarck-Aschoff, M .
ANAESTHESIST, 2001, 50 (03) :171-180
[10]   Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes [J].
Guttmann, J ;
Kessler, V ;
Mols, G ;
Hentschel, R ;
Haberthür, C ;
Geiger, K .
CRITICAL CARE MEDICINE, 2000, 28 (04) :1018-1026