Bar continuity and strain compatibility for high-strength steel reinforcement in reinforced concrete structures

被引:1
作者
Zhao, Ming-Shan [1 ,2 ]
Ding, Miao [1 ]
Chiew, Singping [1 ]
机构
[1] Singapore Inst Technol, Singapore, Singapore
[2] Singapore Inst Technol, 10 Dover Dr, Singapore 138683, Singapore
关键词
bar continuity; mechanical splice; strain compatibility; high-strength steel reinforcement; confinement; CONFINEMENT MODEL; COLUMNS; BEHAVIOR;
D O I
10.1177/13694332231184321
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength steel reinforcement in grade B600 with yield strength of 600 N/mm(2) is gaining popularity for its potential to reduce the total amount of reinforcement used and improve construction productivity. However, longer lapped length is required by the conventional lap splicing method for bar continuity. Besides, the conventional design methods are limiting the strength of reinforcement due to strain compatibility issue which suggest that the concrete would fail before B600 rebar yield. This study investigated the reliability of mechanical couplers as alternative splicing method. Statistical analysis showed that the performance of permanent elongation is well within the specified limit of <0.1 mm and the mean tensile strengths are 15.7%-22.1% higher than the requirement. This study also investigated the effectiveness of confinement on enhancing the strain compatibility between B600 rebars and normal concrete through finite element analysis. Results showed with adequately close stirrups, the B600 bars are able to yield and the overall load resistance could be improved by 24%-27% compared to the unconfined models.
引用
收藏
页码:2325 / 2337
页数:13
相关论文
共 29 条
[1]   Efficiency of CFRP strips as a substitute for carbon steel stirrups in RC columns [J].
Abdul Halim, Nur Hajarul Falahi ;
C. Alih, Sophia ;
Vafaei, Mohammadreza .
MATERIALS AND STRUCTURES, 2020, 53 (05)
[2]  
Abe S., 2011, J STRUCT ENG, V57A, P386
[3]   Experimental seismic behavior of ultra-high performance concrete columns with high strength steel reinforcement [J].
Aboukifa, Mahmoud ;
Moustafa, Mohamed A. .
ENGINEERING STRUCTURES, 2021, 232
[4]  
[Anonymous], 2010, FIB model code for concrete structures 2010
[5]  
BC5, 2019, DES GUID US GRAD B60
[6]   Concrete Subjected to Varying Confinement, I: Experimental Evaluation [J].
Cetisli, Fatih ;
Naito, Clay J. .
JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2009, 7 (02) :239-249
[7]   Design of high-strength steel reinforced concrete columns - a Eurocode 4 approach [J].
Chiew, Sing-Ping ;
Cai, Yan-Qing .
STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2018, 11 (04) :306-314
[8]  
Comite Euro-International du Beton, 1990, CEB-FIP model code 1990: Design code for concrete structures
[9]   HIGH-STRENGTH CONCRETE COLUMNS CONFINED BY RECTANGULAR TIES [J].
Cusson, D ;
Paultre, P .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (03) :783-804
[10]   Splice methods used for reinforcement steel bars: A state-of-the-art review [J].
Dabiri, Hamed ;
Kheyroddin, Ali ;
Dall'Asta, Andrea .
CONSTRUCTION AND BUILDING MATERIALS, 2022, 320