Study Design: A retrospective computed tomography (CT)-based radiological analysis. Purpose: To obtain CT-based morphometric data for the S2 alar iliac (S2AI) screw in the Indian population presenting to School of Medical Sciences and Research, Greater Noida, we used the concept of "safe trajectory" by Pontes and his colleagues in a recent study. Overview of Literature: Although previous CT-based morphometric studies on the S2AI screw have been published for a variety of ethnic groups, morphometric data specifically for the Indian population are scarce. Methods: We used the three-dimensional multiplanar reformatting software to conduct a retrospective CT analysis of 112 consecutive patients who met our exclusion criteria for various abdominal and pelvic pathologies. CT imaging planes were rotated between the S1 and S2 foramen until they matched the ideal S2AI screw trajectory, which was represented by the longest and widest iliac osseous channel observed in the axial CT section. Following the concept of a safe trajectory, S2AI screw morphometric parameters were measured on both sides of the pelvis using corresponding axial and sagittal CT images. Results: In the sagittal and transverse planes on both sides of the pelvis, females had significantly higher screw trajectory angulation than males (p <0.001). On both sides of the pelvis, males had significantly greater iliac width, maximum screw trajectory length, and intrascrotal length than females (p <0.001). On both sides of the pelvis, the S2AI screw entry point in females was significantly deeper than in males from the skin margin (p <0.001). Conclusions: Based on our methodology, we discovered that the S2AI screw trajectory is significantly more caudal and lateral in females, the maximum screw length is sufficient for use in clinical practice regardless of gender, and that 8.5 mm or even larger screw diameters are feasible in the majority of the Indian population.
引用
收藏
页码:130 / 137
页数:8
相关论文
共 24 条
  • [11] A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis
    Kwan, Mun Keong
    Jeffry, Amit
    Chan, Chris Yin Wei
    Saw, Lim Beng
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2012, 34 (03) : 217 - 227
  • [12] Li C, 2019, INT J CLIN EXP MED, V12, P5661
  • [13] Morphometric measurement and applicable feature analysis of sacral alar-iliac screw fixation using forward engineering
    Liu, Fang
    Yang, Yang
    Wen, Chaolun
    Guo, Linya
    Wang, Aiping
    Huang, Wenhua
    Li, Yanbing
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 177 - 186
  • [14] Comparative tomographic study of the S2-alar-iliac screw versus the iliac screw
    Morais Tavares Junior, Mauro Costa
    Vaz de Souza, Joao Paco
    Freitas Araujo, Thiego Pedro
    Marcon, Raphael Martus
    Cristante, Alexandre Fogaca
    Pessoa de Barros Filho, Tarcisio Eloy
    Letaif, Olavo Biraghi
    [J]. EUROPEAN SPINE JOURNAL, 2019, 28 (04) : 855 - 862
  • [15] Moshirfar A, 2009, Semin Spine Surg, V21, P55
  • [16] Nanda Ankur, 2020, J Clin Orthop Trauma, V11, P853, DOI 10.1016/j.jcot.2020.07.022
  • [17] Biomechanical Evaluation of S2 Alar-Iliac Screws Effect of Length and Quad-Cortical Purchase as Compared With Iliac Fixation
    O'Brien, Joseph R.
    Yu, Warren
    Kaufman, Brian E.
    Bucklen, Brandon
    Salloum, Kanaan
    Khalil, Saif
    Gudipally, Manasa
    [J]. SPINE, 2013, 38 (20) : E1250 - E1255
  • [18] Comparison of pelvic fixation techniques in neuromuscular spinal deformity correction:: Galveston rod versus iliac and lumbosacral screws
    Peelle, Michael W.
    Lenke, Lawrence G.
    Bridwell, Keith H.
    Sides, Brenda
    [J]. SPINE, 2006, 31 (20) : 2392 - 2398
  • [19] Sponseller PD, 2007, Semin Spine Surg, V2, P83, DOI DOI 10.1017/CBO9781107415324.004
  • [20] Feasibility of Sub-Axial Cervical Laminar Screws, Including C7, in the Indian Population: A Study on 50 Patients Using Computed Tomography-Based Morphometry Measurements
    Srivastava, Abhishek
    Nanda, Geetanjali
    Mahajan, Rajat
    Nanda, Ankur
    Batra, Sahil
    Mishra, Nirajana
    Pandita, Naveen
    Chhabra, Harvinder Singh
    [J]. ASIAN SPINE JOURNAL, 2019, 13 (01) : 7 - 12