Method of computational design for additive manufacturing of hip endoprosthesis based on basic-cell concept

被引:8
作者
Bolshakov, Pavel [1 ]
Kuchumov, Alex G. [2 ,3 ,8 ]
Kharin, Nikita [4 ,5 ]
Akifyev, Kirill [4 ]
Statsenko, Evgeny [6 ]
Silberschmidt, Vadim V. [7 ]
机构
[1] Tupolev Kazan Natl Res Tech Univ, Dept Machine Sci & Engn Graph, Kazan, Russia
[2] Perm Natl Res Polytech Univ, Dept Computat Math Mech & Biomech, Perm, Russia
[3] Perm Natl Res Polytech Univ, Lab Mech Biocompatible Mat & Devices, Perm, Russia
[4] Kazan Fed Univ, NI Lobachevsky Inst Math & Mech, Dept Theoret Mech, Kazan, Russia
[5] Kazan Fed Univ, Inst Engn, Kazan, Russia
[6] Kazan Fed Univ, Inst Geol & Petr Technol, Lab X ray Tomog, Kazan, Russia
[7] Loughborough Univ, Wolfson Sch Mech Elect & Mfg Engn, Loughborough, England
[8] Perm Natl Res Polytech Univ, Dept Computat Math Mech & Biomech, Komsomlskiy Prospect 29, Perm 614990, Russia
关键词
additive manufacturing; porous constructions; structural design; TOPOLOGY OPTIMIZATION; POROUS BIOMATERIALS; BONE; STRESS; LOAD; PROSTHESIS; IMPLANTS; SCAFFOLDS; DENSITY; STEM;
D O I
10.1002/cnm.3802
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Endoprosthetic hip replacement is the conventional way to treat osteoarthritis or a fracture of a dysfunctional joint. Different manufacturing methods are employed to create reliable patient-specific devices with long-term performance and biocompatibility. Recently, additive manufacturing has become a promising technique for the fabrication of medical devices, because it allows to produce complex samples with various structures of pores. Moreover, the limitations of traditional fabrication methods can be avoided. It is known that a well-designed porous structure provides a better proliferation of cells, leading to improved bone remodeling. Additionally, porosity can be used to adjust the mechanical properties of designed structures. This makes the design and choice of the structure's basic cell a crucial task. This study focuses on a novel computational method, based on the basic-cell concept to design a hip endoprosthesis with an unregularly complex structure. A cube with spheroid pores was utilized as a basic cell, with each cell having its own porosity and mechanical properties. A novelty of the suggested method is in its combination of the topology optimization method and the structural design algorithm. Bending and compression cases were analyzed for a cylinder structure and two hip implants. The ability of basic-cell geometry to influence the structure's stress-strain state was shown. The relative change in the volume of the original structure and the designed cylinder structure was 6.8%. Computational assessments of a stress-strain state using the proposed method and direct modeling were carried out. The volumes of the two types of implants decreased by 9% and 11%, respectively. The maximum von Mises stress was 600 MPa in the initial design. After the algorithm application, it increased to 630 MPa for the first type of implant, while it is not changing in the second type of implant. At the same time, the load-bearing capacity of the hip endoprostheses was retained. The internal structure of the optimized implants was significantly different from the traditional designs, but better structural integrity is likely to be achieved with less material. Additionally, this method leads to time reduction both for the initial design and its variations. Moreover, it enables to produce medical implants with specific functional structures with an additive manufacturing method avoiding the constraints of traditional technologies. The generalized structural algorithm (a combination of structural and topological designs) was implemented for cylindrical initial geometry and two types of implants. Bending and compression cases were analyzed. Using the basic-cell concept, the load-bearing capacity of the hip endoprostheses was retained.image
引用
收藏
页数:23
相关论文
共 90 条
  • [1] Patient-specific design process and evaluation of a hip prosthesis femoral stem
    Abdelaa, Osama
    Darwish, Saied
    El-Hofy, Hassan
    Saito, Yoshio
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (06) : 271 - 290
  • [2] Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties
    Ahmadi, Seyed Mohammad
    Yavari, Saber Amin
    Wauthle, Ruebn
    Pouran, Behdad
    Schrooten, Jan
    Weinans, Harrie
    Zadpoor, Amir A.
    [J]. MATERIALS, 2015, 8 (04): : 1871 - 1896
  • [3] Peri-Implant bone response around porous-surface dental implants: A preclinical meta-analysis
    Ahmed, Abeer
    Al-Rasheed, Abdulaziz
    Badwelan, Mohammed
    Alghamdi, Hamdan S.
    [J]. SAUDI DENTAL JOURNAL, 2021, 33 (05) : 239 - 247
  • [4] Al-Ali M.A., 2017, World J. Mech, V07, P323, DOI DOI 10.4236/WJM.2017.712025
  • [5] Topology optimised metallic bone plates produced by electron beam melting: a mechanical and biological study
    Al-Tamimi, Abdulsalam Abdulaziz
    Huang, Boyang
    Vyas, Cian
    Hernandez, Miguel
    Peach, Chris
    Bartolo, Paulo
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2019, 104 (1-4) : 195 - 210
  • [6] Topology Optimization to reduce the stress shielding effect for orthopedic applications
    Al-Tamimi, Abdulsalam A.
    Peach, Chris
    Fernandes, Paulo Rui
    Cseke, Akos
    Bartolo, Paulo J. D. S.
    [J]. 3RD CIRP CONFERENCE ON BIOMANUFACTURING, 2017, 65 : 202 - 206
  • [7] Andrade-Campos A., 2012, Journal of Biomedical Science and Engineering, V5, P229, DOI [DOI 10.4236/JBISE.2012.55030, 10.4236/jbise.2012.55030]
  • [8] High-strength porous biomaterials for bone replacement: A strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints
    Arabnejad, Sajad
    Johnston, R. Burnett
    Pura, Jenny Ann
    Singh, Baljinder
    Tanzer, Michael
    Pasini, Damiano
    [J]. ACTA BIOMATERIALIA, 2016, 30 : 345 - 356
  • [9] Arra A., 2021, AIP CONF P, V2358
  • [10] Implant surface characteristics and their effect on osseointegration
    Barfeie, A.
    Wilson, J.
    Rees, J.
    [J]. BRITISH DENTAL JOURNAL, 2015, 218 (05) : E9 - E9