Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?

被引:0
|
作者
Cetinkaya, Zeki [1 ]
Elcik, Deniz [2 ]
Kelesoglu, Saban [2 ]
Cesur, Burak [3 ]
Yasan, Mustafa [4 ]
Karabiyik, Ugur [5 ]
Bingol, Bilge [6 ]
Kalay, Nihat [2 ]
Topsakal, Ramazan [2 ]
Tuncay, Aydin [7 ]
Dogan, Ali [2 ]
Inanc, Mehmet Tugrul [2 ]
机构
[1] Elazig Fethi Sekin City Hosp, Dept Cardiol, Elazig, Turkiye
[2] Erciyes Univ, Fac Med, Dept Cardiol, Kayseri, Turkiye
[3] Kayseri State Hosp, Dept Cardiol, Kayseri, Turkiye
[4] Kastamonu Training & Res Hosp, Dept Cardiol, Kastamonu, Turkiye
[5] Nigde Training & Res Hosp, Dept Cardiol, Nigde, Turkiye
[6] Kirsehir Training & Res Hosp, Dept Cardiol, Kirsehir, Turkiye
[7] Erciyes Univ, Dept Cardiovasc Surg, Fac Med, Kayseri, Turkiye
关键词
Transcatheter aortic valve implantation; bundle branch block; AV block; atrial-his interval; REPLACEMENT; STENOSIS; BLOCK; PROSTHESIS;
D O I
10.55730/1300-0144.5750
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study.Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded.Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664-0.996, p = 0.013). The preprocedure HV distance was 98 +/- 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 +/- 15.55 ms, showing a borderline significant difference (p = 0.049).Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infrahisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.
引用
收藏
页码:1799 / 1806
页数:10
相关论文
共 50 条
  • [41] Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Cost Analysis
    Ahmad, Mansoor
    Patel, Jay N.
    Loc, Brian L.
    Vipparthy, Sharath C.
    Divecha, Chirag
    Barzallo, Pablo X.
    Kim, Minchul
    Baman, Timir
    Barzallo, Marco
    Mungee, Sudhir
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [42] Risk Assessment of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation in Patients With Preexisting Right Bundle Branch Block
    Sugiyama, Yoichi
    Miyashita, Hirokazu
    Yokoyama, Hiroaki
    Ochiai, Tomoki
    Shishido, Koki
    Jalanko, Mikko
    Yamanaka, Futoshi
    Vahasilta, Tommi
    Saito, Shigeru
    Laine, Mika
    Moriyama, Noriaki
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 151 - 160
  • [43] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Qi, Yiming
    Lin, Xiaolei
    Pan, Wenzhi
    Zhang, Xiaochun
    Ding, Yuefan
    Chen, Shasha
    Zhang, Lei
    Zhou, Daxin
    Ge, Junbo
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [44] Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study
    Kaya, Esra
    Andresen, Kristoffer
    Lie, oyvind H.
    Aaberge, Lars
    Haugaa, Kristina H.
    Edvardsen, Thor
    Skulstad, Helge
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (04) : 539 - 547
  • [45] Prognostic impact of permanent pacemaker implantation after transcatheter aortic valve replacement
    Sharobeem, Sam
    Boulmier, Dominique
    Leurent, Guillaume
    Bedossa, Marc
    Leclercq, Christophe
    Mabo, Philippe
    Martins, Raphael P.
    Tomasi, Jacques
    Verhoye, Jean-Philippe
    Donal, Erwan
    Sost, Gwenaelle
    Le Guellec, Marielle
    Le Breton, Herve
    Auffret, Vincent
    HEART RHYTHM, 2022, 19 (07) : 1124 - 1132
  • [46] Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation
    Goncalves, Cristian Rodrigues
    Bertog, Stefan
    Tholakanahalli, Venkatakrishna
    Roemer, Albrecht
    Hofmann, Ilona
    Reinartz, Markus
    Gafoor, Sameer
    Sievert, Kolja
    Schnelle, Nalan
    Grunwald, Iris
    Sievert, Horst
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (06) : 726 - 729
  • [47] Predictors of high-degree conduction disturbances and pacemaker implantation after transcatheter aortic valve replacement: Prognostic role of the electrophysiological study
    Ferreira, Thomas
    Da Costa, Antoine
    Cerisier, Alexis
    Vidal, Nicolas
    Guichard, Jean Baptiste
    Romeyer, Cecile
    Barthelemy, Jean Claude
    Isaaz, Karl
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 843 - 855
  • [48] Predictors of permanent pacemaker requirement after transcatheter aortic valve implantation: Insights from a Brazilian Registry
    Gensas, Caroline S.
    Caixeta, Adriano
    Siqueira, Dimytri
    Carvalho, Luiz A.
    Sarmento-Leite, Rogerio
    Mangione, Jose A.
    Lemos, Pedro A.
    Colafranceschi, Alexandre S.
    Caramori, Paulo
    Ferreira, Maria Cristina
    Abizaid, Alexandre
    Brito, Fabio S., Jr.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (02) : 248 - 252
  • [49] Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices
    B. Gonska
    M. Keßler
    J. Wöhrle
    W. Rottbauer
    J. Seeger
    Netherlands Heart Journal, 2018, 26 : 620 - 627
  • [50] Use of Electrophysiological Studies in Transcatheter Aortic Valve Implantation
    Tovia-Brodie, Oholi
    Michowitz, Yoav
    Belhassen, Bernard
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2020, 9 (01) : 20 - 27