RETRACTED: Reverse iontophoresis generated by porous microneedles produces an electroosmotic flow for glucose determination (Retracted article. See vol. 283, 2025)

被引:8
作者
He, Qi-yao [1 ,4 ]
Zhao, Jia-hao [2 ]
Du, Shi-ming [3 ]
Li, De-gui [2 ,4 ]
Luo, Zhi-wei [3 ]
You, Xue-qiu [2 ,4 ]
Liu, Jing [2 ]
机构
[1] Jimei Univ, Sch Nav, Xiamen 361021, Peoples R China
[2] Jimei Univ, Sch Marine Informat Engn, Xiamen 361021, Peoples R China
[3] Xiamen Univ Technol, Sch Mech & Automot Engn, Xiamen 361024, Peoples R China
[4] Fujian Prov Key Lab Ocean Informat Percept & Intel, Xiamen, Peoples R China
基金
中国国家自然科学基金;
关键词
Polymer-based ion-conductive porous micro; needles; Electroosmotic flow; Glucose concentration measurement; Reverse ion electroosmosis; MANAGEMENT; PATCH;
D O I
10.1016/j.talanta.2023.125156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood glucose level is a key indicator of a patient's health, notably the symptoms associated with diabetes. Painless and continuously monitored interstitial glucose is highly preferable for diabetes management. Microneedle arrays can be used as an effective but minimally invasive technique to break the skin barrier. Simultaneous reverse iontophoresis enables non-invasive interstitial fluid extraction from the intercellular matrix <= 25 mm under the skin's surface. Here, we describe an ion-conductive porous microneedle (PMN)-based glucose sensing device combined with reverse ion electroosmosis, in which glucose extraction can be significantly enhanced. Four novel benefits of ionophoresis are concurrently brought about by the charged PMN: (1) decreased transdermal resistance with the low invasive penetration of highly resistant stratum corneum; (2) a reduction of transdermal resistance through interconnectivity; (3) the movement of larger molecules through linked micropores; and (4) the production of an electroosmotic flow (EOF). The EOF generated by PMN is effectively extracted from the skin interstitial fluid for glucose concentration measurement. And this will likely contribute to the long-term home management of chronic diseases.
引用
收藏
页数:9
相关论文
共 29 条
  • [1] Toward Closing the Loop: An Update on Insulin Pumps and Continuous Glucose Monitoring Systems
    Aye, Tandy
    Block, Jen
    Buckingham, Bruce
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2010, 39 (03) : 609 - +
  • [2] Sotagliflozin in Patients with Diabetes and Chronic Kidney Disease
    Bhatt, Deepak L.
    Szarek, Michael
    Pitt, Bertram
    Cannon, Christopher P.
    Leiter, Lawrence A.
    McGuire, Darren K.
    Lewis, Julia B.
    Riddle, Matthew C.
    Inzucchi, Silvio E.
    Kosiborod, Mikhail N.
    Cherney, David Z. I.
    Dwyer, Jamie P.
    Scirica, Benjamin M.
    Bailey, Clifford J.
    Diaz, Rafael
    Ray, Kausik K.
    Udell, Jacob A.
    Lopes, Renato D.
    Lapuerta, Pablo
    Steg, P. Gabriel
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2021, 384 (02) : 129 - 139
  • [3] Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
    Brown, S. A.
    Kovatchev, B. P.
    Raghinaru, D.
    Lum, J. W.
    Buckingham, B. A.
    Kudva, Y. C.
    Laffel, L. M.
    Levy, C. J.
    Pinsker, J. E.
    Wadwa, R. P.
    Dassau, E.
    Doyle, F. J., III
    Anderson, S. M.
    Church, M. M.
    Dadlani, V
    Ekhlaspour, L.
    Forlenza, G. P.
    Isganaitis, E.
    Lam, D. W.
    Kollman, C.
    Beck, R. W.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (18) : 1707 - 1717
  • [4] Toward Biofunctional Microneedles for Stimulus Responsive Drug Delivery
    Cahill, Ellen M.
    O'Cearbhaill, Eoin D.
    [J]. BIOCONJUGATE CHEMISTRY, 2015, 26 (07) : 1289 - 1296
  • [5] Effect of microneedles shape on skin penetration and minimally invasive continuous glucose monitoring in vivo
    Chua, Beelee
    Desai, Shashi P.
    Tierney, Michael J.
    Tamada, Janet A.
    Jina, Arvind N.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 373 - 381
  • [6] Dutt-Ballerstadt Ralph, 2012, J Diabetes Sci Technol, V6, P362
  • [7] Closed-loop insulin delivery for treatment of type 1 diabetes
    Elleri, Daniela
    Dunger, David B.
    Hovorka, Roman
    [J]. BMC MEDICINE, 2011, 9
  • [8] Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform
    Emaminejad, Sam
    Gao, Wei
    Wu, Eric
    Davies, Zoe A.
    Nyein, Hnin Yin Yin
    Challa, Samyuktha
    Ryan, Sean P.
    Fahad, Hossain M.
    Chen, Kevin
    Shahpar, Ziba
    Talebi, Salmonn
    Milla, Carlos
    Javey, Ali
    Davis, Ronald W.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (18) : 4625 - 4630
  • [9] Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
    Gao, Wei
    Emaminejad, Sam
    Nyein, Hnin Yin Yin
    Challa, Samyuktha
    Chen, Kevin
    Peck, Austin
    Fahad, Hossain M.
    Ota, Hiroki
    Shiraki, Hiroshi
    Kiriya, Daisuke
    Lien, Der-Hsien
    Brooks, George A.
    Davis, Ronald W.
    Javey, Ali
    [J]. NATURE, 2016, 529 (7587) : 509 - +
  • [10] Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors
    Guo, Shiqi
    Wu, Kaijin
    Li, Chengpan
    Wang, Hao
    Sun, Zheng
    Xi, Dawei
    Zhang, Sheng
    Ding, Weiping
    Zaghloul, Mona E.
    Wang, Changning
    Castro, Fernando A.
    Yang, Dong
    Zhao, Yunlong
    [J]. MATTER, 2021, 4 (03) : 969 - 985