Microcatheter movement in the aneurysm due to low-profile visualized intraluminal support deployment: An in vitro study

被引:1
|
作者
Ikeda, Hiroyuki [1 ]
Kinosada, Masanori [1 ]
Uezato, Minami [1 ]
Kurosaki, Yoshitaka [1 ]
Chin, Masaki [1 ]
Yamagata, Sen [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Neurosurg, 1-1-1 Miwa, Kurashiki 7108602, Japan
关键词
Aneurysm; Device; Stent; LVIS; Microcatheter; Jailing technique; INTRACRANIAL SACCULAR ANEURYSMS; COIL EMBOLIZATION; STENTS;
D O I
10.1016/j.neurad.2022.03.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: When a microcatheter is in the aneurysm, it may move due to low-profile visualized intralumi-nal support (LVIS) deployment. This study was designed to determine this mechanism.Methods: Six silicon aneurysm models were created by combining the aneurysm location (side wall or bifur-cation) and the parent vessel configuration (straight, ipsilateral bending, or contralateral bending). After adjusting the microcatheter tip position in the aneurysm by pushing or pulling, an LVIS stent was deployed to cover the aneurysm neck, and the changes in the microcatheter tip position was measured. Pushing and pulling were performed 15 times each for each model, for a total of 180 experiments.Results: In all experiments, the microcatheter tip moved with LVIS deployment. The total movement distance was 3.00</n>1.59 mm, which was significantly different between the push and pull groups (p = 0.049), between the three side-wall aneurysm models (p<0.0001), and between the three bifurcation aneurysm models (p<0.0001). Backward movement in the aneurysm occurred in 21% (37/180). The frequency of backward movement was significantly different between the side-wall and bifurcation aneurysm models (p = 0.0265) and between the push and pull groups (p<0.0001). The forward movement distance was significantly differ-ent between the side-wall (n = 78) and bifurcation (n = 65) aneurysm models (p<0.0001).Conclusions: The aneurysm location, the parent vessel configuration, and adjustment of the microcatheter tip position by pushing or pulling may affect the total movement distance and forward/backward movement of the microcatheter tip due to LVIS deployment.(c) 2022 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 50 条
  • [1] Factors related to microcatheter passage through the trans-cell approach using a low-profile visualized intraluminal support device: an in-vitro study
    Ikeda, Hiroyuki
    Kinosada, Masanori
    Kurosaki, Yoshitaka
    Handa, Akira
    Chin, Masaki
    Yamagata, Sen
    JOURNAL OF NEURORADIOLOGY, 2022, 49 (01) : 87 - 93
  • [2] Effects of acute angle, proximal bending, and distal bending in the deployment vessels on incomplete low-profile visualized intraluminal support (LVIS) expansion: an in vitro study
    Ikeda, Hiroyuki
    Otsuka, Ryotaro
    Uesaka, Daisuke
    Sano, Noritaka
    Torikoshi, Sadaharu
    Hayase, Makoto
    Toda, Hiroki
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (05) : 453 - 458
  • [3] Incomplete stent apposition of low-profile visualized intraluminal support stents in the treatment of cerebral aneurysms
    Zhang, Huan
    Gao, Xiaoping
    Liang, Hui
    Ren, Yi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (06) : 591 - 597
  • [4] Final results of the US humanitarian device exemption study of the low-profile visualized intraluminal support (LVIS) device
    Fiorella, David
    Arthur, Adam
    Boulos, Alan
    Diaz, Orlando
    Jabbour, Pascal
    Pride, Lee
    Turk, Aquilla S.
    Woo, Henry H.
    Derdeyn, Colin
    Millar, John
    Clifton, Andrew
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (09) : 894 - 897
  • [5] Three-dimensional fusion imaging to assess apposition of low-profile visualized intraluminal support stent for intracranial aneurysm coiling
    Kato, Naoki
    Ishibashi, Toshihiro
    Otani, Katharina
    Abe, Yukiko
    Sano, Tohru
    Nagayama, Gota
    Fuga, Michiyasu
    Hataoka, Shunsuke
    Kan, Issei
    Murayama, Yuichi
    WORLD NEUROSURGERY-X, 2024, 23
  • [6] Endovascular Treatment of Wide-Necked Intracranial Aneurysms with the Scepter XC Balloon Catheter, with Low-Profile Visualized Intraluminal Support (LVIS) Jr. Deployment as a "Bailout" Technique
    Wallace, Adam N.
    Kayan, Yasha
    Almandoz, Josser E. Delgado
    Fease, Jennifer L.
    Milner, Anna A.
    Scholz, Jill M.
    WORLD NEUROSURGERY, 2019, 121 : E798 - E807
  • [7] Endovascular treatment of PICA aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr) device
    Samaniego, Edgar A.
    Abdo, German
    Hanel, Ricardo A.
    Lima, Andrey
    Ortega-Gutierrez, Santiago
    Dabus, Guilherme
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (10) : 1030 - 1033
  • [8] Long-term outcomes of Low-profile Visualized Intraluminal Support device usage in stent-assisted coiling of intracranial aneurysm
    Yoo, Dong Hyun
    Cho, Young Dae
    Moon, Jusun
    Lee, Jeongjun
    Kang, Hyun-Seung
    Cho, Won-Sang
    Kim, Jeong Eun
    Hwang, Gyojun
    Kwon, O-Ki
    Han, Moon Hee
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 50 : 287 - 291
  • [9] Comparison of Two Endovascular Interventions with Low-Profile Visualized Intraluminal Support or Pipeline Embolization Device in Middle Cerebral Arterial Aneurysms Patients
    Lv, Zhonghua
    Zhu, Yong
    Wang, Wei
    Wu, Qiangjun
    Li, Wen
    Li, Qiang
    Xu, Liang
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (06) : 590 - 594
  • [10] Small ruptured and unruptured complex cerebral aneurysms: Single center experience of low-profile visualized intraluminal support stent
    Lv, Xianli
    Jiang, Chuhan
    Liang, Shikai