Heat and mass transfer during ice resurfacing process in ice rink

被引:3
作者
Zhang, Zhenying [1 ]
Wang, Shiqi [1 ]
Chang, Li [1 ]
Wu, Yumeng [1 ]
Huang, Chunsong [1 ]
Chen, Yanhua [1 ]
Wang, Hongli [2 ]
机构
[1] North China Univ Sci & Technol, Coll Architecture & Civil Engn, Tangshan 063210, Peoples R China
[2] North China Univ Sci & Technol, Coll Met & Energy, Tangshan 063210, Peoples R China
关键词
Ice rink; Ice resurfacing; Heat and mass transfer; Phase transition; Dynamic boundary; MODEL;
D O I
10.1016/j.buildenv.2024.111270
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The strict guidelines for ice resurfacing in ice sports facilities call for freezing the ice with the permitted period, achieving ice quality standards, and using the least amount of energy feasible. A transient heat and mass transfer dynamic model with phase transition for the ice resurfacing is established and validated. The influences of resurfacing water volume and initial surface temperature on transient fresh surface temperature, transient heat transfer rate, and evaporation (condensation) rate during the ice resurfacing process are analyzed to explore methods of reducing ice resurfacing time for the ice surface area of 1800 m2. The results indicate that at the time of pouring flood water onto the fresh surface, convective mass transfer contributes around 79.1% of the total transient heat transfer rate. The cooling pipe surface heat transfer rate peaks between the 14th and the 18th minute, with a value of 355 kW-389 kW. It takes about 5-13 min for the fresh surface temperature to reach the required temperature. The impact of the resurfacing on the ice rink's heat and mass transfer takes 140-180 min to disappear because of thermal inertia. The cooling pipe surface heat transfer rate's peak value decreases as the resurfacing water volume lowers and the initial surface temperature rises. The condensation rate increases from 16.3 g/s to 28.2 g/s with the initial surface temperature increasing from -3.5 degrees C to -9.5 degrees C. Lowering the cooling pipe temperature reduces resurfacing time by about 6.7 min and steady time by 19-132 min.
引用
收藏
页数:13
相关论文
共 27 条
  • [1] Modeling phase change materials embedded in building enclosure: A review
    AL-Saadi, Saleh Nasser
    Zhai, Zhiqiang
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 21 : 659 - 673
  • [2] [Anonymous], 2005, ASHRAE HDB FUND
  • [3] Ashrae Ashrae, 2018, Handbook Refrigeration SI Edition, Chapter44: Ice Rinks
  • [4] Bellache O, 2006, ASHRAE TRAN, V112, P706
  • [5] Comparison between moving-boundary and distributed models for predicting the time evolution of the solidification front in ice trays
    Berno, Guilherme M.
    Loyola, Felipe R.
    Hermes, Christian J. L.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 118
  • [6] Bogomoloff H, 2016, IIHF Ice Rink Guide - Chapter 3: Technical Guidelines of an Ice Rink
  • [7] Calculation of refrigeration loads by convection, radiation and condensation in ice rinks using a transient 3D zonal model
    Daoud, Ahmed
    Galanis, Nicolas
    Bellache, Omar
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1782 - 1790
  • [8] Ferrantelli A., 2019, ADV BUILD ENERGY RES, V15, P499
  • [9] Haghighi E.B., 2014, INT J CIV ENV STRUCT, V8, P635
  • [10] Gas-storage ice grown from water containing microbubbles
    Inada, Takaaki
    Hatakeyama, Tomohiko
    Takemura, Fumio
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03): : 462 - 471