Estimation of diagnostic reference levels for pediatric head computed tomography in Yaoundé

被引:1
作者
Kamdem, Eddy F. [1 ]
Fotue, Alain J. [1 ]
Kouam, Brice B. F. [2 ]
Abogo, Serge [3 ]
Samba, Odette N. [4 ]
机构
[1] Univ Dschang, Fac Sci, Dept Phys, Condensed Matter Elect & Signal Proc Res Unit, Dschang, Cameroon
[2] Yaounde Gen Hosp, Dept Radiol, Yaounde, Cameroon
[3] Bafoussam Reg Hosp, Dept Radiol, Bafoussam, Cameroon
[4] Natl Social Insurance Fund Hosp, Dept Radiog, Yaounde, Cameroon
关键词
CT;
D O I
10.1093/rpd/ncad298
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The diagnostic reference levels (DRLs) are determined from dosimetry studies to compare and manage patient doses in medical imaging procedures. The aim of this work was to establish the first DRLs for pediatric patients during the most common computed tomography (CT) procedures in Yaounde, Cameroon during routine head CT examinations to know how to improve our clinical practice tomorrow. The sample was classified per age group: <= 1-, 1-5-, 5-10- and 10-15-y-old. The retrospective study was used. The proposed DRLs were defined as 75th percentile of the median values of the distributions. In terms of Volume CT Dose Index (CTDIvol) and dose length product (DLP), the DRLs obtained for the ages groups were: 28.6 mGy and 545.8 mGy.cm, 32.6 mGy and 735 mGy.cm, 37.1 mGy and 761.6 mGy.cm and 44.2 mGy and 1081.2 mGy.cm, respectively. DRLs in Yaounde for DLP were higher than those of comparison literatures. The Yaounde CTDIvol was higher than the comparison literatures except for the IAEA (2015) values for the three older age groups. The DRLs reported in Yaounde were compared to Morocco 2020, Switzerland 2018, IAEA 2015 and Iran 2020 values. The estimation of this first DRL for pediatric head CT scan in Yaounde must be a starting point to spread this investigation towards other examinations and imaging modalities across the country. Therefore, optimization of the CT scan procedures and orderly updates of local DRLs are necessary to improve radioprotection.
引用
收藏
页码:259 / 263
页数:5
相关论文
共 19 条
[1]   DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY [J].
Benmessaoud, M. ;
Dadouch, A. ;
Talbi, M. ;
Tahiri, M. ;
El-ouardi, Y. .
RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) :400-408
[2]   Effective dose in paediatric computed tomography [J].
Chapple, CL ;
Willis, S ;
Frame, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :107-115
[3]  
European Commission, 2018, RAD PROT, V2315-2826, P33
[4]  
Galanski M., 2006, PEDIAT CT EXPOSURE P
[5]   European Society of Paediatric Radiology Computed Tomography and Dose Task Force: European guidelines on diagnostic reference levels for paediatric imaging [J].
Granata, Claudio ;
Sorantin, Erich ;
Seuri, Raija ;
Owens, Catherine M. .
PEDIATRIC RADIOLOGY, 2018, 49 (05) :702-705
[6]  
Harata Y., 2006, DIAGNOSTIC REFERENCE, V46, P119
[7]   Radiation Dose for Body CT Protocols: Variability of Scanners at One Institution [J].
Jaffe, Tracy A. ;
Yoshizumi, Terry T. ;
Toncheva, Greta ;
Anderson-Evans, Colin ;
Lowry, Carolyn ;
Miller, Chad M. ;
Nelson, Rendon C. ;
Ravin, Carl E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1141-1147
[8]  
Kanda R., 2020, JPN J RADIOL, V39, P1
[9]  
Nagel HD., 2007, RAD DOSE ADULT PEDIA
[10]   National survey of doses from CT in the UK: 2003 [J].
Shrimpton, P. C. ;
Hillier, M. C. ;
Lewis, M. A. ;
Dunn, M. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (948) :968-980