Performance of supercritical carbon dioxide (sCO2) centrifugal compressors in the Brayton cycle considering non-equilibrium condensation and exergy efficiency

被引:14
作者
Ding, Hongbing [1 ]
Dong, Yuanyuan [1 ]
Zhang, Yu [1 ]
Wen, Chuang [2 ]
Yang, Yan [3 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin 300072, Peoples R China
[2] Univ Reading, Sch Built Environm, Reading RG6 6AH, England
[3] Univ Exeter, Fac Environm Sci & Econ, Exeter EX4 4QF, England
基金
中国国家自然科学基金; 英国工程与自然科学研究理事会;
关键词
Brayton cycle; Supercritical carbon dioxide; sCO2 centrifugal compressor; Nonequilibrium condensation; Exergy destruction; Compressor efficiency; GENERATION;
D O I
10.1016/j.enconman.2023.117849
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Brayton cycle, with supercritical carbon dioxide (sCO2) centrifugal compressors at its core, has received widespread attention for its high efficiency and energy savings. Therefore, the in-depth exploration of the internal flow field behaviour of sCO2 centrifugal compressors becomes especially critical. In the present study, we develop a mathematical model to evaluate the performance of a sCO2 compressor considering non-equilibrium condensation in transonic flows. It is validated that the model can well predict the sCO2 phase change and is a reliable vehicle for the performance analysis in this study. Further, by incorporating the cubic spline curve extrapolation method, the model can handle the complex thermodynamic properties of CO2 under a metastable state. Then, this study presents a series of analyses for the effects under different conditions, such as different inlet temperatures and rotational speeds, on the flow field characteristics and performance of the compressor. It's further found that with an increase in inlet temperature, the condensation intensity is suppressed and the condensation position moves backwards. At the 50% blade span, the liquid phase fraction decreases from 5.15% at 306 K to 1.32% at 325 K. Finally, from an energy perspective, this study implements a quantitative analysis of the exergy destruction and exergy efficiency of the compressor. The results show that the exergy efficiency under the wet steam model is quite different when the inlet temperature changes. With the decrease of rotating speeds, the exergy efficiency will decrease. The exergy efficiency reaches 81.35% at 20,000 rpm, which is 51.02% higher than that at 10,000 rpm.
引用
收藏
页数:16
相关论文
共 37 条
[31]  
Shao WY, 2021, Appl. Therm. Eng, P183
[32]   Aerodynamic Optimization Design of a 150 kW High Performance Supercritical Carbon Dioxide Centrifugal Compressor without a High Speed Requirement [J].
Shi, Dongbo ;
Xie, Yong Hui .
APPLIED SCIENCES-BASEL, 2020, 10 (06)
[33]   Experimental investigation on performance degradation of a supercritical CO2 radial compressor by foreign object damage [J].
Son, Seongmin ;
Cho, Seong Kuk ;
Lee, Jeong Ik .
APPLIED THERMAL ENGINEERING, 2021, 183 (183)
[34]   Development of supercritical CO2 turbomachinery off-design model using 1D mean-line method and Deep Neural Network [J].
Son, Seongmin ;
Jeong, Yongju ;
Cho, Seong Kuk ;
Lee, Jeong Ik .
APPLIED ENERGY, 2020, 263
[35]   Optimization design for supercritical carbon dioxide compressor based on simulated annealing algorithm [J].
Tang, Songsheng ;
Peng, Minjun ;
Xia, Genglei ;
Wang, Ge ;
Zhou, Cheng .
ANNALS OF NUCLEAR ENERGY, 2020, 140
[36]   CFD modelling of non-equilibrium condensation of CO2 within a supersonic nozzle using metastability approach [J].
Vijayakumaran, Harrivin ;
Lemma, Tamiru Alemu .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2021, 85 (85)
[37]   Design and performance analysis of compressor and turbine in supercritical CO2 power cycle based on system-component coupled optimization [J].
Wang, Jiangfeng ;
Guo, Yumin ;
Zhou, Kehan ;
Xia, Jiaxi ;
Li, Yan ;
Zhao, Pan ;
Dai, Yiping .
ENERGY CONVERSION AND MANAGEMENT, 2020, 221