High-performance liquid chromatography-based assay optimization for the detection of plasma amino acids for applications in metabolic disorders in developing countries

被引:2
|
作者
Wasim, Muhammad [1 ,2 ,3 ]
Khan, Haq Nawaz [1 ,2 ,3 ]
Tawab, Abdul [1 ,2 ]
Habib, Fazal E. [1 ,2 ]
Iqbal, Mazhar [1 ,2 ]
Awan, Fazli Rabbi [1 ]
机构
[1] Natl Inst Biotechnol & Genet Engn NIBGE, Hlth Biotechnol Div, Jhang Rd, POB 577, Faisalabad, Pakistan
[2] Pakistan Inst Engn & Appl Sci PIEAS, Nilore, Pakistan
[3] Aga Khan Univ, Biol & Biomed Sci, Karachi, Pakistan
关键词
aminoacidopathies; fluorescence detector; inborn errors of metabolism; newborn screening; o-phthaldialdehyde; INBORN-ERRORS; FATTY-ACIDS; HPLC METHOD; PHENYLALANINE; FLUORESCENCE; BLOOD; TYROSINE; QUANTIFICATION; VALIDATION; METHIONINE;
D O I
10.1002/sscp.202300119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasma amino acids are generally analyzed through ion exchange chromatography, a reproducible but time-consuming method. Here, we report the optimization of a reverse-phase-high-performance liquid chromatography with fluorescence detector (RP-HPLC-FLD) assay for the detection and quantification of plasma amino acids for potential applications in metabolic disorders (e.g., aminoacidopathies, a rare group of Inborn Errors of Metabolism). For assay development, initially standard amino acids were derivatized with orthophthalaldehyde-3-mercaptopropionic acid (OPA-3-MPA) and filtered through a 0.20 mu m syringe filter. The excitation and emission wavelengths of 240-450 nm (.ex-.em) were used for the detection of amino acids. Chromatographic separation was achieved by gradient RP-HPLC-FLD through C18 symmetry column (150 x 4.6 mm, particle size 3.5 mu m). HPLC assay was successfully optimized and was able to detect amino acids in the range of 10-400 ng/mL and good linearity (R2 > 0.98) was achieved in the mixture for each standard amino acid. Moreover, the current assay showed great efficiency with two additional advantages: the use of low- cost mobile phases, and the detection and quantification of amino acids at low level (ng/mL) concentration in biofluids. This assay could be applied for the analysis of human plasma to identify aminoacidopathies in newborn screening programs, and other metabolic disorders.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Optimized method for the determination of itopride in human plasma by high-performance liquid chromatography with fluorimetric detection
    Ptacek, Pavel
    Klima, Josef
    Macek, Jan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (8-9): : 842 - 846
  • [32] Measurement of Posaconazole, Itraconazole, and Hydroxyitraconazole in Plasma/Serum by High-Performance Liquid Chromatography With Fluorescence Detection
    Buckner, Sara L.
    Ceesay, M. Mansour
    Pagliuca, Antonio
    Morgan, Phillip E.
    Flanagan, Robert J.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (06) : 735 - 741
  • [33] A non-derivatized high-performance liquid chromatography method for simultaneous quantification of hydroxyl acids and amino acids in ammonolysis reactions
    Huang, Ying
    Guo, Yan-qin
    Xu, Zhou
    Ding, Li
    Cheng, Yun-hui
    Chen, Mao-long
    ANALYTICAL METHODS, 2025, 17 (07) : 1590 - 1602
  • [34] Method validation for the determination of furosemide in plasma by liquid-liquid extraction and high-performance liquid chromatography with fluorescence detection
    Gomez, C
    von Plessing, C
    Godoy, CG
    Reinbach, R
    Godoy, R
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2005, 50 (02) : 479 - 482
  • [35] QUANTITATION OF 17-ESTRADIOL IN RABBIT PLASMA BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    Yilmaz, Bilal
    Kadioglu, Yucel
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (08) : 1126 - 1137
  • [36] Validation of the assay of metoprolol in human plasma using liquid-liquid extraction and high performance liquid chromatography with fluorescence detection
    Farca, A
    Tache, F
    Medvedovici, A
    David, V
    CHEMIA ANALITYCZNA, 2003, 48 (04): : 677 - 688
  • [37] High-Performance Liquid Chromatography-Based Standardization of Stigmasterol in Moringa oleifera: Method Development and Validation Through Design of Experiment Approach
    Kunchanur, Mahantesh
    Mannur, Vinodhkumar S.
    Koli, Rahul
    SEPARATION SCIENCE PLUS, 2024, 7 (09):
  • [38] Simultaneous determination of selected ionophoric coccidiostats and amino acids in feed premixes using high-performance liquid chromatography-ultraviolet detection method
    Zayed, Sahar
    Belal, Fathalla
    Barghash, Sona
    Fouad, Fatma
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (04)
  • [39] Analysis of Urinary Amino Acids by High-Performance Liquid Chromatography with Fluorescence Detection Using 2,3-Naphthalenedicarboxaldehyde as Fluorescence Derivatization Reagent
    Ishida, Yuma
    Inoue, Ryoto
    Tsunoda, Makoto
    SEPARATIONS, 2023, 10 (04)
  • [40] Measurement of pentosidine in human plasma protein by a single-column high-performance liquid chromatography method with fluorescence detection
    Scheijen, Jean L. J. M.
    van de Waarenburg, Marjo P. H.
    Stehomer, Coen D. A.
    Schalkwijk, Casper G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (07): : 610 - 614