High-performance liquid chromatography-based assay optimization for the detection of plasma amino acids for applications in metabolic disorders in developing countries

被引:2
|
作者
Wasim, Muhammad [1 ,2 ,3 ]
Khan, Haq Nawaz [1 ,2 ,3 ]
Tawab, Abdul [1 ,2 ]
Habib, Fazal E. [1 ,2 ]
Iqbal, Mazhar [1 ,2 ]
Awan, Fazli Rabbi [1 ]
机构
[1] Natl Inst Biotechnol & Genet Engn NIBGE, Hlth Biotechnol Div, Jhang Rd, POB 577, Faisalabad, Pakistan
[2] Pakistan Inst Engn & Appl Sci PIEAS, Nilore, Pakistan
[3] Aga Khan Univ, Biol & Biomed Sci, Karachi, Pakistan
关键词
aminoacidopathies; fluorescence detector; inborn errors of metabolism; newborn screening; o-phthaldialdehyde; INBORN-ERRORS; FATTY-ACIDS; HPLC METHOD; PHENYLALANINE; FLUORESCENCE; BLOOD; TYROSINE; QUANTIFICATION; VALIDATION; METHIONINE;
D O I
10.1002/sscp.202300119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasma amino acids are generally analyzed through ion exchange chromatography, a reproducible but time-consuming method. Here, we report the optimization of a reverse-phase-high-performance liquid chromatography with fluorescence detector (RP-HPLC-FLD) assay for the detection and quantification of plasma amino acids for potential applications in metabolic disorders (e.g., aminoacidopathies, a rare group of Inborn Errors of Metabolism). For assay development, initially standard amino acids were derivatized with orthophthalaldehyde-3-mercaptopropionic acid (OPA-3-MPA) and filtered through a 0.20 mu m syringe filter. The excitation and emission wavelengths of 240-450 nm (.ex-.em) were used for the detection of amino acids. Chromatographic separation was achieved by gradient RP-HPLC-FLD through C18 symmetry column (150 x 4.6 mm, particle size 3.5 mu m). HPLC assay was successfully optimized and was able to detect amino acids in the range of 10-400 ng/mL and good linearity (R2 > 0.98) was achieved in the mixture for each standard amino acid. Moreover, the current assay showed great efficiency with two additional advantages: the use of low- cost mobile phases, and the detection and quantification of amino acids at low level (ng/mL) concentration in biofluids. This assay could be applied for the analysis of human plasma to identify aminoacidopathies in newborn screening programs, and other metabolic disorders.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Determination of free amino acids in blood plasma by high-performance liquid chromatography with fluorescence detection
    Czauderna, M
    Kowalczyk, J
    JOURNAL OF ANIMAL AND FEED SCIENCES, 1998, 7 (04): : 453 - 463
  • [2] Analysis of Amino Acids, Including Taurine, in Plasma of Cats Using High-Performance Liquid Chromatography with Fluorescence Detection
    Kuroki, Hiroshi
    Tokieda, Saku
    Shimada, Kazumi
    Tsunoda, Makoto
    CHROMATOGRAPHY, 2025, 46 (01) : 41 - 46
  • [3] Determination of vancomycin in human plasma using high-performance liquid chromatography with fluorescence detection
    Abu-Shandi, Khalid Hamad
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (02) : 527 - 532
  • [4] Sensitive assay for the determination of fluvastatin in plasma utilizing high-performance liquid chromatography with fluorescence detection
    Al-Rawithi, S
    Hussein, RF
    Alzahrani, A
    THERAPEUTIC DRUG MONITORING, 2003, 25 (01) : 88 - 92
  • [5] Determination of amino acids in human biological fluids by high-performance liquid chromatography: critical review
    Galezowska, Grazyna
    Ratajczyk, Joanna
    Wolska, Lidia
    AMINO ACIDS, 2021, 53 (07) : 993 - 1009
  • [6] Determination of Aristolochic Acids by High-Performance Liquid Chromatography with Fluorescence Detection
    Wang, Yinan
    Chan, Wan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (25) : 5859 - 5864
  • [7] Determination of metoprolol in human plasma and urine by high-performance liquid chromatography with fluorescence detection
    Yilmaz, Bilal
    Asci, Ali
    Arslan, Sakir
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (13) : 1904 - 1908
  • [8] A sensitive high-performance liquid chromatography method with fluorescence detection for the determination of fatty acids as exemplified for Dendrobium species
    Zhang, Shijuan
    Song, Cuihua
    Chen, Guang
    Xia, Lian
    Wang, Xiaoyan
    You, Jinmao
    EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2013, 115 (10) : 1155 - 1163
  • [9] Determination of vancomycin in human plasma using high-performance liquid chromatography with fluorescence detection
    Khalid Hamad Abu-Shandi
    Analytical and Bioanalytical Chemistry, 2009, 395 : 527 - 532
  • [10] High-performance liquid chromatography-based assay for glutathione transferase theta 2 activity: Application to characterize interindividual variability in human liver fractions
    Zhang, Yongjie
    Wijaya, Lukas
    Dekker, Stefan J.
    Vermeulen, Nico P. E.
    Commandeur, Jan N. M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 181 - 188