A computational model to simulate spectral modulation and speech perception experiments of cochlear implant users

被引:3
|
作者
Alvarez, Franklin [1 ,2 ]
Kipping, Daniel [1 ,2 ]
Nogueira, Waldo [1 ,2 ]
机构
[1] Hannover Med Sch, Hannover, Germany
[2] Cluster Excellence Hearing4All, Hannover, Germany
基金
欧洲研究理事会;
关键词
computational model; cochlear implant; neural health; sound coding strategies; speech-in-noise recognition; spectral modulation detection; speech understanding prediction; PULSATILE ELECTRICAL-STIMULATION; AUDITORY-NERVE; SPIRAL GANGLION; INTELLIGIBILITY; DISCRIMINATION; INTERFERENCE; DEGENERATION; RECOGNITION; EXCITATION; RESOLUTION;
D O I
10.3389/fninf.2023.934472
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Speech understanding in cochlear implant (CI) users presents large intersubject variability that may be related to different aspects of the peripheral auditory system, such as the electrode-nerve interface and neural health conditions. This variability makes it more challenging to proof differences in performance between different CI sound coding strategies in regular clinical studies, nevertheless, computational models can be helpful to assess the speech performance of CI users in an environment where all these physiological aspects can be controlled. In this study, differences in performance between three variants of the HiRes Fidelity 120 (F120) sound coding strategy are studied with a computational model. The computational model consists of (i) a processing stage with the sound coding strategy, (ii) a three-dimensional electrode-nerve interface that accounts for auditory nerve fiber (ANF) degeneration, (iii) a population of phenomenological ANF models, and (iv) a feature extractor algorithm to obtain the internal representation (IR) of the neural activity. As the back-end, the simulation framework for auditory discrimination experiments (FADE) was chosen. Two experiments relevant to speech understanding were performed: one related to spectral modulation threshold (SMT), and the other one related to speech reception threshold (SRT). These experiments included three different neural health conditions (healthy ANFs, and moderate and severe ANF degeneration). The F120 was configured to use sequential stimulation (F120-S), and simultaneous stimulation with two (F120-P) and three (F120-T) simultaneously active channels. Simultaneous stimulation causes electric interaction that smears the spectrotemporal information transmitted to the ANFs, and it has been hypothesized to lead to even worse information transmission in poor neural health conditions. In general, worse neural health conditions led to worse predicted performance; nevertheless, the detriment was small compared to clinical data. Results in SRT experiments indicated that performance with simultaneous stimulation, especially F120-T, were more affected by neural degeneration than with sequential stimulation. Results in SMT experiments showed no significant difference in performance. Although the proposed model in its current state is able to perform SMT and SRT experiments, it is not reliable to predict real CI users' performance yet. Nevertheless, improvements related to the ANF model, feature extraction, and predictor algorithm are discussed.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Normal-Hearing Listeners' and Cochlear Implant Users' Perception of Pitch Cues in Emotional Speech
    Gilbers, Steven
    Fuller, Christina
    Gilbers, Dicky
    Broersma, Mirjam
    Goudbeek, Martijn
    Free, Rolien
    Baskent, Deniz
    I-PERCEPTION, 2015, 6 (05): : 1 - 19
  • [22] Impact of Microphone Configuration on Speech Perception of Cochlear Implant Users in Traffic Noise
    Weissgerber, Tobias
    Bandeira, Mariana
    Brendel, Martina
    Stoever, Timo
    Baumann, Uwe
    OTOLOGY & NEUROTOLOGY, 2019, 40 (03) : E198 - E205
  • [23] Effect of Spectral Contrast Enhancement on Speech-on-Speech Intelligibility and Voice Cue Sensitivity in Cochlear Implant Users
    El Boghdady, Nawal
    Langner, Florian
    Gaudrain, Etienne
    Baskent, Deniz
    Nogueira, Waldo
    EAR AND HEARING, 2021, 42 (02) : 271 - 289
  • [24] Influence of "novel" speech processors on the speech perception performance of cochlear implant users
    Baljic, I.
    HNO, 2009, 57 (06) : 563 - +
  • [25] Speech Perception of Elderly Cochlear Implant Users Under Different Noise Conditions
    Hast, Anne
    Schluecker, Luisa
    Digeser, Frank
    Liebscher, Tim
    Hoppe, Ulrich
    OTOLOGY & NEUROTOLOGY, 2015, 36 (10) : 1638 - 1643
  • [26] Intra-Cochlear Current Spread Correlates with Speech Perception in Experienced Adult Cochlear Implant Users
    Joly, Charles-Alexandre
    Reynard, Pierre
    Hermann, Ruben
    Seldran, Fabien
    Gallego, Stephane
    Idriss, Samar
    Thai-Van, Hung
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [27] Speech perception with interaction-compensated simultaneous stimulation and long pulse durations in cochlear implant users
    Schatzer, Reinhold
    Koroleva, Inna
    Griessner, Andreas
    Levin, Sergey
    Kusovkov, Vladislav
    Yanov, Yuri
    Zierhofer, Clemens
    HEARING RESEARCH, 2015, 322 : 99 - 106
  • [28] Cross-modal reorganization and speech perception in cochlear implant users
    Doucet, M. E.
    Bergeron, F.
    Lassonde, M.
    Ferron, P.
    Lepore, F.
    BRAIN, 2006, 129 : 3376 - 3383
  • [29] Ceiling effects for speech perception tests in pediatric cochlear implant users
    Spitzer, Emily R.
    Landsberger, David M.
    Lichtl, Alexandra J.
    Waltzman, Susan B.
    COCHLEAR IMPLANTS INTERNATIONAL, 2024, 25 (01) : 69 - 80
  • [30] Bilateral and Unilateral Cochlear Implant Users Compared on Speech Perception in Noise
    Dunn, Camille C.
    Noble, William
    Tyler, Richard S.
    Kordus, Monika
    Gantz, Bruce J.
    Ji, Haihong
    EAR AND HEARING, 2010, 31 (02) : 296 - 298