A computational model to simulate spectral modulation and speech perception experiments of cochlear implant users

被引:3
|
作者
Alvarez, Franklin [1 ,2 ]
Kipping, Daniel [1 ,2 ]
Nogueira, Waldo [1 ,2 ]
机构
[1] Hannover Med Sch, Hannover, Germany
[2] Cluster Excellence Hearing4All, Hannover, Germany
基金
欧洲研究理事会;
关键词
computational model; cochlear implant; neural health; sound coding strategies; speech-in-noise recognition; spectral modulation detection; speech understanding prediction; PULSATILE ELECTRICAL-STIMULATION; AUDITORY-NERVE; SPIRAL GANGLION; INTELLIGIBILITY; DISCRIMINATION; INTERFERENCE; DEGENERATION; RECOGNITION; EXCITATION; RESOLUTION;
D O I
10.3389/fninf.2023.934472
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Speech understanding in cochlear implant (CI) users presents large intersubject variability that may be related to different aspects of the peripheral auditory system, such as the electrode-nerve interface and neural health conditions. This variability makes it more challenging to proof differences in performance between different CI sound coding strategies in regular clinical studies, nevertheless, computational models can be helpful to assess the speech performance of CI users in an environment where all these physiological aspects can be controlled. In this study, differences in performance between three variants of the HiRes Fidelity 120 (F120) sound coding strategy are studied with a computational model. The computational model consists of (i) a processing stage with the sound coding strategy, (ii) a three-dimensional electrode-nerve interface that accounts for auditory nerve fiber (ANF) degeneration, (iii) a population of phenomenological ANF models, and (iv) a feature extractor algorithm to obtain the internal representation (IR) of the neural activity. As the back-end, the simulation framework for auditory discrimination experiments (FADE) was chosen. Two experiments relevant to speech understanding were performed: one related to spectral modulation threshold (SMT), and the other one related to speech reception threshold (SRT). These experiments included three different neural health conditions (healthy ANFs, and moderate and severe ANF degeneration). The F120 was configured to use sequential stimulation (F120-S), and simultaneous stimulation with two (F120-P) and three (F120-T) simultaneously active channels. Simultaneous stimulation causes electric interaction that smears the spectrotemporal information transmitted to the ANFs, and it has been hypothesized to lead to even worse information transmission in poor neural health conditions. In general, worse neural health conditions led to worse predicted performance; nevertheless, the detriment was small compared to clinical data. Results in SRT experiments indicated that performance with simultaneous stimulation, especially F120-T, were more affected by neural degeneration than with sequential stimulation. Results in SMT experiments showed no significant difference in performance. Although the proposed model in its current state is able to perform SMT and SRT experiments, it is not reliable to predict real CI users' performance yet. Nevertheless, improvements related to the ANF model, feature extraction, and predictor algorithm are discussed.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Spectrotemporal Modulation Detection and Speech Perception by Cochlear Implant Users
    Won, Jong Ho
    Moon, Il Joon
    Jin, Sunhwa
    Park, Heesung
    Woo, Jihwan
    Cho, Yang-Sun
    Chung, Won-Ho
    Hong, Sung Hwa
    PLOS ONE, 2015, 10 (10):
  • [2] Spectral Modulation Detection Performance and Speech Perception in Pediatric Cochlear Implant Recipients
    Davidson, Lisa S.
    Geers, Ann E.
    Uchanski, Rosalie M.
    AMERICAN JOURNAL OF AUDIOLOGY, 2021, 30 (04) : 1076 - 1087
  • [3] Effects of harmonicity on Mandarin speech perception in cochlear implant users
    Shi, Mingyue
    Meng, Qinglin
    Zhou, Huali
    Li, Jiawen
    Mo, Yefei
    Zheng, Nengheng
    SPEECH COMMUNICATION, 2025, 169
  • [4] The effect of a coding strategy that removes temporally masked pulses on speech perception by cochlear implant users
    Lamping, Wiebke
    Goehring, Tobias
    Marozeau, Jeremy
    Carlyon, Robert P.
    HEARING RESEARCH, 2020, 391
  • [5] Speech Perception with Spectrally Non-overlapping Maskers as Measure of Spectral Resolution in Cochlear Implant Users
    O'Neill, Erin R.
    Kreft, Heather A.
    Oxenham, Andrew J.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2019, 20 (02): : 151 - 167
  • [6] Speech Prosody Perception in Cochlear Implant Users With and Without Residual Hearing
    Marx, Mathieu
    James, Christopher
    Foxton, Jessica
    Capber, Amandine
    Fraysse, Bernard
    Barone, Pascal
    Deguine, Olivier
    EAR AND HEARING, 2015, 36 (02) : 239 - 248
  • [7] Behavioral Measures of Temporal Processing and Speech Perception in Cochlear Implant Users
    Blankenship, Chelsea
    Zhang, Fawen
    Keith, Robert
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2016, 27 (09) : 701 - 713
  • [8] Neural Modulation Transmission Is a Marker for Speech Perception in Noise in Cochlear Implant Users
    Gransier, Robin
    Luke, Robert
    van Wieringen, Astrid
    Wouters, Jan
    EAR AND HEARING, 2020, 41 (03) : 591 - 602
  • [9] Frequency change detection and speech perception in cochlear implant users
    Zhang, Fawen
    Underwood, Gabrielle
    McGuire, Kelli
    Liang, Chun
    Moore, David R.
    Fu, Qian-Jie
    HEARING RESEARCH, 2019, 379 : 12 - 20
  • [10] Effects of stimulation rate on modulation detection and speech recognition by cochlear implant users
    Arora, Komal
    Vandali, Andrew
    Dowell, Richard
    Dawson, Pam
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (02) : 123 - 132