Clustering Wind Turbines for SCADA Data-Based Fault Detection

被引:16
作者
Du, Bojian [1 ]
Narusue, Yoshiaki [1 ]
Furusawa, Yoko [2 ]
Nishihara, Nozomu [3 ]
Indo, Kentaro [3 ]
Morikawa, Hiroyuki [1 ]
Iida, Makoto [2 ]
机构
[1] Univ Tokyo, Bunkyo ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Res Ctr Adv Sci & Technol, Meguro ku, Tokyo 1538904, Japan
[3] Eurus Tech Serv Corp, Tokyo 1050001, Japan
关键词
Wind farms; Fault detection; Wind turbines; Data models; Wind speed; Predictive models; Monitoring; Wind turbine; fault detection; SCADA data; clustering; false alarm; MODEL;
D O I
10.1109/TSTE.2022.3215672
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Condition monitoring systems are commonly employed for incipient fault detection of wind turbines (WTs) to reduce downtime and increase availability. Data from supervisory control and data acquisition (SCADA) systems offer a potential monitoring solution. Multi-turbine approaches, which merge variables recorded from different WTs on the same wind farm, have been developed to improve fault detection performance by reducing the influence of variations in environmental conditions. However, in complex terrain, environmental conditions vary among WTs. Moreover, manual control (e.g., maintenance and curtailment) can also raise false alarms in some WTs. Here, the false alarm characteristics of a wind farm in complex terrain are investigated. A clustering-based multi-turbine fault detection approach is proposed, consisting of three steps: WT clustering, single-turbine modeling, and fault indicator calculation. First, k-medoids clustering with dependent multivariate dynamic time warping is applied for WT clustering. Then, an autoregressive neural network is used to construct a single-turbine model. Finally, residuals between median values of the model output of all WTs in the same cluster and the target WT are used to calculate the anomaly level. Evaluation results for real large-scale SCADA data confirm that the proposed approach raises fewer false alarms without degrading detection performance.
引用
收藏
页码:442 / 452
页数:11
相关论文
共 30 条
[1]   Critical comparison of power-based wind turbine fault-detection methods using a realistic framework for SCADA data simulation [J].
Aziz, Usama ;
Charbonnier, Sylvie ;
Berenguer, Christophe ;
Lebranchu, Alexis ;
Prevost, Frederic .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 144
[2]   Analysis of SCADA data for early fault detection, with application to the maintenance management of wind turbines [J].
Bangalore, P. ;
Patriksson, M. .
RENEWABLE ENERGY, 2018, 115 :521-532
[3]   Control chart monitoring of wind turbine generators using the statistical inertia of a wind farm average [J].
Cambron, P. ;
Masson, C. ;
Tahan, A. ;
Pelletier, F. .
RENEWABLE ENERGY, 2018, 116 :88-98
[4]   Hierarchical method for wind turbine prognosis using SCADA data [J].
Chen, Niya ;
Yu, Rongrong ;
Chen, Yao ;
Xie, Hailian .
IET RENEWABLE POWER GENERATION, 2017, 11 (04) :403-410
[5]   Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data [J].
Dao, Phong B. ;
Staszewski, Wieslaw J. ;
Barszcz, Tomasz ;
Uhl, Tadeusz .
RENEWABLE ENERGY, 2018, 116 :107-122
[6]  
Dodge Y., 2006, OXFORD DICT STAT TER
[7]   Power Performance Verification of a Wind Farm Using the Friedman's Test [J].
Hernandez, Wilmar ;
Luis Lopez-Presa, Jose ;
Maldonado-Correa, Jorge L. .
SENSORS, 2016, 16 (06)
[8]   Condition Monitoring of Wind Turbine Generators Using SCADA Data Analysis [J].
Jin, Xiaohang ;
Xu, Zhuangwei ;
Qiao, Wei .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (01) :202-210
[9]  
Kim K, 2012, PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, P2069
[10]   Monitoring Wind Farms With Performance Curves [J].
Kusiak, Andrew ;
Verma, Anoop .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2013, 4 (01) :192-199