Detection of the p53 Gene Mutation Using an Ultra-sensitive and Highly Selective Electrochemical DNA Biosensor

被引:3
|
作者
Fernando Garcia-Melo, Luis [1 ]
Chagoya Pio, Norma Andrea [1 ]
Morales-Rodriguez, Miguel [2 ]
Madrigal-Bujaidar, Eduardo [3 ]
Madrigal-Santillan, Eduardo O. [4 ]
Alvarez-Gonzalez, Isela [3 ]
Pineda Cruces, Rosa N. [1 ]
Batina, Nikola [1 ]
机构
[1] Univ Autonoma Metropolitana Iztapalapa UAM I, Lab Nanotecnol & Ingn Mol, Area Electroquim, Dept Quim,CBI, Av San Rafael Atlixco 186, Ciudad De Mexico 09340, Mexico
[2] Univ Politecn Valle Mexico, Div Ingn Nanotecnol, Av Mexiquense S-N Esquina Av Univ Politecn, Tultitlan 54910, Estado De Mexic, Mexico
[3] Inst Politecn Nacl, Lab Genet, Escuela Nacl Ciencias Biol, Ave Wilfrido Massieu S-N, Ciudad De Mexico 07738, Mexico
[4] Inst Politecn Nacl, Lab Med Conservac, Escuela Super Med, Unidad Casco Santo Tomas, Ciudad De Mexico 11340, Mexico
关键词
p53; gene; electrochemical DNA biosensor; doxorubicin; cyclic voltammetry; SINGLE NUCLEOTIDE MUTATION; SELF-ASSEMBLED MONOLAYERS; TUMOR-SUPPRESSOR GENE; GOLD NANOPARTICLES; CARBON NANOTUBES; POINT MUTATION; PNA BIOSENSOR; SENSOR; QUANTIFICATION; HYBRIDIZATION;
D O I
10.29356/jmcs.v67i1.1880
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The p53 gene- "the guardian of the genome"-is responsible for maintaining the integrity of the genome, along with cell cycle regulation, apoptosis, and cell differentiation. New analytical devices are needed to recognize the main alterations this gene could suffer, since it is one of the most frequent in human cancer. For this reason, we developed an electrochemical DNA biosensor with high sensitivity and specificity to monitor the 175p2 mutation of the p53 gene. We modified a screen-printed gold electrode (SPGE) by immobilizing a thiolated DNA probe sequence with 11-mercaptoundecanoic acid to detect its complementary sequence through the hybridization reaction. Doxorubicin (Dox) was used to increase the sensitivity of the biosensor, and the entire process was evaluated using the Cyclic Voltammetry (CV) technique. The measurement range of the developed device is from 1 fM to 100 nM of the p53 gene mutation with a limit of detection (LOD) of 2.2 fM. In the presence of Dox, the LOD increased up to 175 aM, becoming one of the highest efficiency devices in the field. The electrochemical DNA biosensor selectively detects the p53 suppressor gene mutation; it distinguishes between different non-complementary and complementary sequences. Our results indicate a high potential of our sensor for the p53 gene 175p2 mutation detection, which is convenient in the early diagnosis of diseases related to this gene.
引用
收藏
页码:33 / 45
页数:13
相关论文
共 50 条
  • [41] Detection of circulating p53 gene mutation in HCC patients by DHPLC
    Wang, HD
    Ren, J
    Si, XM
    Zhang, YJ
    You, XH
    Liu, WC
    INTERNATIONAL JOURNAL OF CANCER, 2002, : 112 - 112
  • [42] Sensitive detection of p53 mutation:: Analysis by direct sequencing and multisequence analysis
    Rozemuller, EH
    Kropveld, A
    Kreyveld, E
    Leppers, FGJ
    Scheidel, KC
    Slootweg, PJ
    Tilanus, MGJ
    CANCER DETECTION AND PREVENTION, 2001, 25 (02): : 109 - 116
  • [43] Enzyme-free electrochemical biosensor based on bio-barcode amplification for ultra-sensitive detection of microRNA
    Xi, Huai
    Liang, Xiaolin
    Huang, Guidan
    Liang, Jinhua
    Li, Dandan
    Wen, Qilin
    Zhang, Yun
    Xiao, Xiaofen
    Zhu, Wenyuan
    ANALYTICAL SCIENCES, 2024, 40 (02) : 285 - 290
  • [44] Ultra-sensitive electrochemical DNA biosensor based on signal amplification using gold nanoparticles modified with molybdenum disulfide, graphene and horseradish peroxidase
    Xiaoyu Cao
    Microchimica Acta, 2014, 181 : 1133 - 1141
  • [45] Ultra-sensitive monitoring mutations in cancer patients using superRCA mutation detection assays
    Chen, L.
    Westrom, S.
    Eriksson, A.
    Pandzic, T.
    Lehmann, S.
    Cavelier, L.
    Landegren, U.
    ANNALS OF ONCOLOGY, 2022, 33 (08) : S1416 - S1416
  • [46] One-step triggered branched DNA nanostrucuture for ultra-sensitive electrochemical detection of microRNA
    Xiong, Zhengwei
    Pan, Ruochen
    Hu, Qiuhong
    Yun, Wen
    Li, Ning
    Wang, Qiang
    Yang, Lizhu
    MICROCHEMICAL JOURNAL, 2020, 158
  • [47] Ultra-sensitive electrochemical DNA biosensor based on signal amplification using gold nanoparticles modified with molybdenum disulfide, graphene and horseradish peroxidase
    Cao, Xiaoyu
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 1133 - 1141
  • [48] Effect of pH on the Interaction of Gold Nanoparticles with DNA and Application in the Detection of Human p53 Gene Mutation
    Liping Sun
    Zhaowu Zhang
    Shuang Wang
    Jianfeng Zhang
    Hui Li
    Lei Ren
    Jian Weng
    Qiqing Zhang
    Nanoscale Research Letters, 4
  • [49] Effect of pH on the Interaction of Gold Nanoparticles with DNA and Application in the Detection of Human p53 Gene Mutation
    Sun, Liping
    Zhang, Zhaowu
    Wang, Shuang
    Zhang, Jianfeng
    Li, Hui
    Ren, Lei
    Weng, Jian
    Zhang, Qiqing
    NANOSCALE RESEARCH LETTERS, 2009, 4 (03): : 216 - 220
  • [50] Enzyme-free electrochemical biosensor based on bio-barcode amplification for ultra-sensitive detection of microRNA
    Huai Xi
    Xiaolin Liang
    Guidan Huang
    Jinhua Liang
    Dandan Li
    Qilin Wen
    Yun Zhang
    Xiaofen Xiao
    Wenyuan Zhu
    Analytical Sciences, 2024, 40 : 285 - 290