Comparative study on flexural performance of ultra-high performance concrete beams reinforced with steel rebar and steel plate

被引:6
作者
Yan, Banfu [1 ]
Chen, Qiuyan [1 ]
Qiu, Minghong [2 ,6 ]
Zhu, Yanping [3 ]
Tu, Bing [1 ]
Shao, Xudong [4 ,5 ]
机构
[1] Guangxi Univ, Sch Civil Engn & Architecture, Nanning, Peoples R China
[2] Univ Hong Kong, Dept Civil Engn, Hong Kong, Peoples R China
[3] Missouri Univ Sci & Technol, Civil Architectural & Environm Engn, Rolla, MO USA
[4] Hunan Univ, Key Lab Wind & Bridge Engn Hunan Prov, Changsha, Peoples R China
[5] Hunan Univ, Natl Key Lab Bridge Safety & Resilience, Changsha, Peoples R China
[6] Univ Hong Kong, Dept Civil Engn, Pokfulam, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
cracking behavior; flexural behavior; reinforcement patterns; steel plate; ultimate capacity; ultra-high performance concrete (UHPC); STRUCTURAL PERFORMANCE; BEHAVIOR; STRENGTH; GFRP;
D O I
10.1002/suco.202300145
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To enhance the mechanical and constructional performance of the ultra-high performance concrete (UHPC) beams, the steel plate placed at the bottom surface of the UHPC beam is utilized to replace the ordinary steel rebars. In this paper, four 3.2 m UHPC T-shaped beams with different reinforcement patterns of ordinary steel rebars and external steel plate were fabricated and comparatively tested under flexure loading. Their damage patterns, load versus deflection behavior, flexural capacity, load versus strain behavior, moment versus curvature behavior, stiffness, and crack development were investigated. The flexural experiments indicated that the external steel plate, positioned at the bottom surface of the UHPC members, could resolve the difficulty of installing ordinary steel rebars in slender UHPC components and improve its constructional performance. Compared with the inside steel rebar reinforcement, the employment of the steel plate at the bottom surface of the UHPC beam can effectively increase the distance from the neutral axis to the tensile reinforcement at the serviceability and ultimate states, thereby improving its flexural capacity and stiffness. Additionally, the configuration of the external steel plate was beneficial to reduce the tensile stress level of the tensile reinforcement and limit the opening of UHPC crack width, and thus their crack resistance can be effectively enhanced. Moreover, increasing the thickness of the steel plate or rebar ratio can also significantly improve the flexural capacity, stiffness, and cracking resistance of UHPC beams.
引用
收藏
页码:2536 / 2552
页数:17
相关论文
共 57 条
[1]   Ultra-High Performance Concrete: Mechanical Performance, Durability, Sustainability and Implementation Challenges [J].
Abbas, S. ;
Nehdi, M. L. ;
Saleem, M. A. .
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2016, 10 (03) :271-295
[2]  
[Anonymous], 2004, Strength of recommendations
[3]  
AQSIQ SAC (General Administration of Quality Supervision Inspection and Quarantine of the People's Republic of China Standardization Administration of the People's Republic of China), 2015, 313872015 GBT
[4]   Flexural behaviour of rebar-reinforced ultra-high-performance concrete beams [J].
Chen, Shiming ;
Zhang, Rui ;
Jia, Liang-Jiu ;
Wang, Jun-Yan .
MAGAZINE OF CONCRETE RESEARCH, 2018, 70 (19) :997-1015
[5]   Mechanical behaviour of ultra-high-performance short-fibre-reinforced concrete beams with internal fibre reinforced polymer bars [J].
Ferrier, E. ;
Michel, L. ;
Zuber, B. ;
Chanvillard, G. .
COMPOSITES PART B-ENGINEERING, 2015, 68 :246-258
[6]   Mechanical Behavior of an Innovative Hybrid Beam Made of Glulam and Ultrahigh-Performance Concrete Reinforced with FRP or Steel [J].
Ferrier, E. ;
Labossiere, P. ;
Neale, K. W. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (02) :217-223
[7]  
GB/T 228.1-2010 228.1-2010 G.T, 2010, METALLIC MAT TENSILE
[8]  
Graybeal B.A., 2006, Material property characterization of ultra-high performance concrete
[9]  
Haber ZB., 2018, PROPERTIES BEHAV UHP, P22161
[10]  
JTG/T D64-01-2015, 2015, SPECIFICATIONS DESIG