Effectiveness of Dual-Focus Magnification on Confidence Levels in Optical Diagnosis of Small Colorectal Polyps

被引:0
|
作者
Huynh, Tien M. [1 ,2 ]
Le, Quang D. [1 ,2 ,3 ]
Le, Nhan Q. [2 ]
Le, Huy M. [2 ,4 ]
Quach, Duc T. [1 ,2 ]
机构
[1] Univ Med & Pharm Ho Chi Minh City, Dept Internal Med, Ho Chi Minh City, Vietnam
[2] Univ Med Ctr Ho Chi Minh City, Dept GI Endoscopy, Ho Chi Minh City, Vietnam
[3] Nhan Dan Gia Dinh Hosp, Dept Endoscopy, Ho Chi Minh City, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Dept Surg Pathol, Ho Chi Minh City, Vietnam
关键词
vietnam; confidence level; optical diagnosis; dual-focus; narrow banding imaging; small colorectal polyp; ACCURACY; SYSTEM;
D O I
10.7759/cureus.53545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives Achieving accurate real-time optical diagnoses of colorectal polyps with high -confidence predictions is crucial for appropriate decision -making in daily practice. The dual -focus (DF) magnification mode helps endoscopists scrutinize subtle features of polyp surfaces and vessel patterns. This prospective study aimed to evaluate the impact of DF imaging on enhancing the rate of high -confidence narrow -band imaging (NBI)based optical diagnosis. Methods Consecutive adult patients who underwent colonoscopy and had small colorectal polyps (<10 mm) were enrolled between September 2022 and May 2023. The optical diagnosis of each polyp was evaluated during colonoscopy in two stages by the same endoscopist, utilizing NBI with DF magnification (NDB-DF). A confidence level was assigned to each prediction. High confidence was indicated by clinical judgment when a polyp exhibited distinctive features associated solely with one histological subtype and lacked characteristics of any other subtype. All procedures were carried out with a prototype 190 series Exera III NBI system (Olympus Corporation, Tokyo, Japan) with DF magnification. Results The study included 413 patients with 623 polyps, comprising 483 <= 5 mm and 140 measuring 6-9 mm. The majority were low-grade adenomas (343 lesions), with 17 identified as high-grade adenomas, and none characterized as deep submucosal invasive carcinomas. NBI-DF significantly improved the rate of highconfidence optical diagnoses compared to NBI for both <= 5 mm polyps (93.1% vs. 87.5%, p < 0.0001) and 6-9 mm polyps (97.9% vs. 94.2%, p = 0.03). Furthermore, DF significantly facilitated the assessment of microvessel and surface pattern criteria (p < 0.01). Conclusion DF magnification markedly enhanced the rate of high -confidence NBI-based optical predictions for small colorectal polyps. This technique demonstrates the potential for improving the diagnostic yield in real-time optical diagnosis of colorectal polyps in the Vietnamese setting.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Diagnostic advantage of optical vs electronic magnification for the diagnosis of colonic polyps
    Parra-Blanco, Adolfo
    Matsuda, Takahisa
    Fujii, Takahiro
    Sano, Yasushi
    Diaz-Acosta, Juan-Antonio
    Ortega, Juan a.
    NicolaS-PeRez, David
    Gimeno-Garcia, Antonio Z.
    Jimenez-Sosa, Alejandro
    Carrillo-Palau, Marta
    Quintero, Enrique
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB126 - AB126
  • [22] Optical diagnosis of malignant colorectal polyps: is it feasible?
    van der Vlugt, Manon
    van Doorn, Sascha Corrie
    Wang, Junfeng
    Bastiaansen, Barbara A. J.
    Brosens, Lowewijk A. A.
    Fockens, Paul
    Dekker, Evelien
    ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (07) : E778 - E783
  • [23] Optical Diagnosis of Colorectal Polyps: Recent Developments
    Roupen Djinbachian
    Anne-Julie Dubé
    Daniel von Renteln
    Current Treatment Options in Gastroenterology, 2019, 17 (1) : 99 - 114
  • [24] A Novel Small F-number Ultrasound Transducer with a Dual-Focus Structure
    Zhang, Xiao
    Zeng, Zhoumo
    Zhang, Hui
    Wang, Zhuochen
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [25] Comparison of optical saturation effects in conventional and dual-focus fluorescence correlation spectroscopy
    Loman, Anastasia
    Dertinger, Thomas
    Koberling, Felix
    Enderlein, Joerg
    CHEMICAL PHYSICS LETTERS, 2008, 459 (1-6) : 18 - 21
  • [26] Blue Light Imaging For The Optical Diagnosis Of Small Colorectal Polyps: The Impact Of A Training Intervention
    Subramaniam, Sharmila
    Aepli, Patrick
    Hayee, Bu
    Schoon, Erik
    Stefanovic, Milan
    Bhandari, Pradeep
    SWISS MEDICAL WEEKLY, 2018, 148 : 16S - 16S
  • [27] Differential Diagnosis of Colorectal Polyps With Narrow-Band Imaging Endoscopy Without Magnification
    Park, Moo-in
    Kim, Bong Jin
    Park, Seun-Ja
    Moon, Won
    Kim, Hyung Hun
    Park, Eun Taek
    Kim, Sung Eun
    Lim, Chang Sup
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 421 - 421
  • [28] Narrow-band imaging with dual focus magnification in differentiating colorectal neoplasia
    Singh, Rajvinder
    Jayanna, Mahesh
    Navadgi, Suresh
    Ruszkiewicz, Andrew
    Saito, Yutaka
    Uedo, Noriya
    DIGESTIVE ENDOSCOPY, 2013, 25 : 16 - 20
  • [29] Narrow-Band Imaging Without Optical Magnification for Histologic Analysis of Colorectal Polyps
    Rex, Douglas K.
    GASTROENTEROLOGY, 2009, 136 (04) : 1174 - 1181
  • [30] Optical diagnosis of colorectal polyps: can this be learned by everyone?
    Kiesslich, Ralf
    ENDOSCOPY, 2015, 47 (03) : 188 - 189