Sarcopenia diagnosed by ultrasound-assessed quadriceps muscle thickness and handgrip strength predicts mortality in patients on hemodialysis

被引:3
|
作者
Sabatino, Alice [1 ,2 ]
Kooman, Jeroen [3 ]
Avesani, Carla Maria [4 ]
Gregorini, Mariacristina [5 ]
Bianchi, Stefano [6 ]
Regolisti, Giuseppe [2 ,7 ]
Fiaccadori, Enrico [1 ,2 ]
机构
[1] Azienda Osped Univ Parma, UO Nefrol, Via Gramsci 14, I-43100 Parma, Italy
[2] Univ Parma, Dipartimento Med & Chirurg, Parma, Italy
[3] Univ Hosp Maastricht, Maastricht, Netherlands
[4] Karolinska Inst, Dept Clin Sci Technol & Intervent, Div Renal Med & Baxter Novum, Stockholm, Sweden
[5] AUSL IRCCS Reggio Emilia, UOC Nefrol & Dialisi, Reggio Emilia, Italy
[6] Nephrol & Dialysis Unit, Livorno Sud, Tuscany, Italy
[7] Azienda Osped Univ Parma, UO Clin & Immunol Med, Parma, Italy
关键词
Bioimpedance spectroscopy; Hemodialysis; Sarcopenia; Ultrasound; CHRONIC KIDNEY-DISEASE; QUALITY-OF-LIFE; BODY-COMPOSITION MONITOR; PERITONEAL-DIALYSIS; BEDSIDE ULTRASOUND; BIOIMPEDANCE; MALNUTRITION; RELIABILITY; ASSOCIATION; FLUID;
D O I
10.1007/s40620-023-01867-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Estimation of muscle mass is a pivotal component in the diagnosis of protein-energy wasting and sarcopenia. While bioimpedance spectroscopy is a widely accepted technique for the assessment of lean tissue related to the diagnosis of sarcopenia, to date skeletal muscle ultrasound (US) has not gained full acceptance for this purpose. The aim of this study was to assess the predictive value for mortality of the indexed thickness of the quadriceps vastus intermedius, as measured by US, compared to lean tissue index as estimated by bioimpedance spectroscopy, both combined with handgrip strength in a group of patients with end-stage kidney disease (ESKD) on maintenance hemodialysis (HD).Methods The cut-off values for low handgrip strength were < 27 kg for males and < 16 kg for females. The cut-off value for low lean tissue index was obtained from an age-matched healthy control group, with low lean tissue index being defined as values below the 10th percentile of the distribution of healthy subjects. The cut-off values for low quadriceps vastus intermedius thickness index were < 3.44 mm/m(2) for males and < 3.52 mm/m(2 )for females.Results Ultrasound and bioimpedance spectroscopy were performed in 99 patients, and handgrip strength was assessed in 64 patients, all on maintenance HD. After a median follow-up of 28 months (interquartile range 19-41 months) 38 patients died. Lean tissue index was not associated with mortality, while low quadriceps vastus intermedius thickness index and low handgrip strength were associated with an increased hazard of death. In the fully adjusted model, only the combination of low handgrip strength and low quadriceps vastus intermedius thickness index was significantly associated with higher mortality.Conclusion When combined with low handgrip strength, low quadriceps muscle US outperformed low lean tissue index as assessed by bioimpedance spectroscopy in predicting mortality in a cohort of patients on maintenance HD. Ultrasound may be a useful and convenient technique for the assessment of sarcopenia and protein-energy wasting in this patient population.
引用
收藏
页码:993 / 1003
页数:11
相关论文
共 50 条
  • [21] Screening for sarcopenia and obesity by measuring thigh muscle and fat thickness by ultrasound in patients with rheumatoid arthritis
    Tada, Masahiro
    Yamada, Yutaro
    Mandai, Koji
    Hidaka, Noriaki
    OSTEOPOROSIS AND SARCOPENIA, 2021, 7 (02) : 81 - 87
  • [22] Sarcopenia, Low Handgrip Strength, and Low Absolute Muscle Mass Predict Long-Term Mortality in Older Hospitalized Patients: An Observational Inception Cohort Study
    Scheerman, Kira
    Meskers, Carel G. M.
    Verlaan, Sjors
    Maier, Andrea B.
    JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2021, 22 (04) : 816 - +
  • [23] Muscle Thickness and Echogenicity Measured by Ultrasound Could Detect Local Sarcopenia and Malnutrition in Older Patients Hospitalized for Hip Fracture
    Sanz-Paris, Alejandro
    Gonzalez-Fernandez, Mikel
    Enrique Hueso-Del Rio, Luis
    Ferrer-Lahuerta, Eduardo
    Monge-Vazquez, Alejandra
    Losfablos-Callau, Francisco
    Sanclemente-Hernandez, Teresa
    Sanz-Arque, Alejandro
    Miguel Arbones-Mainar, Jose
    NUTRIENTS, 2021, 13 (07)
  • [24] Ultrasound assessment of diaphragm and quadriceps muscles and its relationship with handgrip and respiratory muscle strength in patients with systemic sclerosis: a cross-sectional study
    de Carvalho, Epamela Sulamita Vitor
    Santos, Gabriela da Silva
    de Siqueira, Gisela Rocha
    Duarte, Angela Luzia Branco Pinto
    Dantas, Andrea Tavares
    CLINICAL RHEUMATOLOGY, 2024, 43 (01) : 289 - 295
  • [25] Association of Adductor Pollicis Muscle Thickness and Handgrip Strength with nutritional status in cancer patients
    Valente, Katarina Papera
    Almeida, Betullya Lucas
    Lazzarini, Thailiny Ricati
    de Souza, Vanusa Felicio
    Chaves Ribeiro, Thamirys de Souza
    Guedes de Moraes, Rafael Araujo
    Silva Pereira, Taisa Sabrina
    Guandalini, Valdete Regina
    PLOS ONE, 2019, 14 (08):
  • [26] ESTABLISHED RHEUMATOID ARTHRITIS PATIENTS APPEAR TO HAVE IMPAIRED QUADRICEPS MUSCLE MORPHOLOGY ASSESSED BY ULTRASOUND AND MUSCLE STRENGTH IMPAIRED OVER TIME: A COHORT STUDY
    Santos, L.
    Do Espirito Santo, R. Cavalheiro
    Pena, E.
    Doria, L. Denardi
    Mallmann, A. L.
    Pilotti, S.
    Moraes, D.
    Antunes, M.
    Hax, V.
    Brenol, C.
    Monticielo, O.
    Chakr, R.
    Xavier, R.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 1341 - 1341
  • [27] Association of Ultrasound-Derived Metrics of the Quadriceps Muscle with Protein Energy Wasting in Hemodialysis Patients: A Multicenter Cross-Sectional Study
    Sahathevan, Sharmela
    Khor, Ban-Hock
    Singh, Birinder Kaur Sadu
    Sabatino, Alice
    Fiaccadori, Enrico
    Daud, Zulfitri Azuan Mat
    Ali, Mohammad Syafiq
    Narayanan, Sreelakshmi Sankara
    Tallman, Dina
    Chinna, Karuthan
    Goh, Bak-Leong
    Gafor, Abdul Halim Abdul
    Ahmad, Ghazali
    Morad, Zaki
    Khosla, Pramod
    Karupaiah, Tilakavati
    NUTRIENTS, 2020, 12 (11) : 1 - 16
  • [28] Ultrasound-Assessed Lesion Morphology and Drug-Coated Balloon Treatment for de novo Dysfunctional Arteriovenous Fistula in Hemodialysis Patients
    Suemitsu, Kotaro
    Shiraki, Tatsuya
    Iida, Osamu
    Oka, Kanako
    Ota, Naomi
    Izumi, Masaaki
    JOURNAL OF ENDOVASCULAR THERAPY, 2023,
  • [29] Lower values of handgrip strength and adductor pollicis muscle thickness are associated with hepatic encephalopathy manifestations in cirrhotic patients
    Augusti, L.
    Franzoni, L. C.
    Santos, L. A. A.
    Lima, T. B.
    Ietsugu, M. V.
    Koga, K. H.
    Moriguchi, S. M.
    Betting, L. E.
    Caramori, C. A.
    Silva, G. F.
    Romeiro, F. G.
    METABOLIC BRAIN DISEASE, 2016, 31 (04) : 909 - 915
  • [30] ASSOCIATIONS BETWEEN HANDGRIP STRENGTH AND ULTRASOUND-MEASURED MUSCLE THICKNESS OF THE HAND AND FOREARM IN YOUNG MEN AND WOMEN
    Abe, Takashi
    Counts, Brittany R.
    Barnett, Brian E.
    Dankel, Scott J.
    Lee, Kofan
    Loenneke, Jeremy P.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (08) : 2125 - 2130