Sarcopenia diagnosed by ultrasound-assessed quadriceps muscle thickness and handgrip strength predicts mortality in patients on hemodialysis

被引:3
|
作者
Sabatino, Alice [1 ,2 ]
Kooman, Jeroen [3 ]
Avesani, Carla Maria [4 ]
Gregorini, Mariacristina [5 ]
Bianchi, Stefano [6 ]
Regolisti, Giuseppe [2 ,7 ]
Fiaccadori, Enrico [1 ,2 ]
机构
[1] Azienda Osped Univ Parma, UO Nefrol, Via Gramsci 14, I-43100 Parma, Italy
[2] Univ Parma, Dipartimento Med & Chirurg, Parma, Italy
[3] Univ Hosp Maastricht, Maastricht, Netherlands
[4] Karolinska Inst, Dept Clin Sci Technol & Intervent, Div Renal Med & Baxter Novum, Stockholm, Sweden
[5] AUSL IRCCS Reggio Emilia, UOC Nefrol & Dialisi, Reggio Emilia, Italy
[6] Nephrol & Dialysis Unit, Livorno Sud, Tuscany, Italy
[7] Azienda Osped Univ Parma, UO Clin & Immunol Med, Parma, Italy
关键词
Bioimpedance spectroscopy; Hemodialysis; Sarcopenia; Ultrasound; CHRONIC KIDNEY-DISEASE; QUALITY-OF-LIFE; BODY-COMPOSITION MONITOR; PERITONEAL-DIALYSIS; BEDSIDE ULTRASOUND; BIOIMPEDANCE; MALNUTRITION; RELIABILITY; ASSOCIATION; FLUID;
D O I
10.1007/s40620-023-01867-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Estimation of muscle mass is a pivotal component in the diagnosis of protein-energy wasting and sarcopenia. While bioimpedance spectroscopy is a widely accepted technique for the assessment of lean tissue related to the diagnosis of sarcopenia, to date skeletal muscle ultrasound (US) has not gained full acceptance for this purpose. The aim of this study was to assess the predictive value for mortality of the indexed thickness of the quadriceps vastus intermedius, as measured by US, compared to lean tissue index as estimated by bioimpedance spectroscopy, both combined with handgrip strength in a group of patients with end-stage kidney disease (ESKD) on maintenance hemodialysis (HD).Methods The cut-off values for low handgrip strength were < 27 kg for males and < 16 kg for females. The cut-off value for low lean tissue index was obtained from an age-matched healthy control group, with low lean tissue index being defined as values below the 10th percentile of the distribution of healthy subjects. The cut-off values for low quadriceps vastus intermedius thickness index were < 3.44 mm/m(2) for males and < 3.52 mm/m(2 )for females.Results Ultrasound and bioimpedance spectroscopy were performed in 99 patients, and handgrip strength was assessed in 64 patients, all on maintenance HD. After a median follow-up of 28 months (interquartile range 19-41 months) 38 patients died. Lean tissue index was not associated with mortality, while low quadriceps vastus intermedius thickness index and low handgrip strength were associated with an increased hazard of death. In the fully adjusted model, only the combination of low handgrip strength and low quadriceps vastus intermedius thickness index was significantly associated with higher mortality.Conclusion When combined with low handgrip strength, low quadriceps muscle US outperformed low lean tissue index as assessed by bioimpedance spectroscopy in predicting mortality in a cohort of patients on maintenance HD. Ultrasound may be a useful and convenient technique for the assessment of sarcopenia and protein-energy wasting in this patient population.
引用
收藏
页码:993 / 1003
页数:11
相关论文
共 50 条
  • [1] Quadriceps muscle thickness assessed by ultrasound is independently associated with mortality in hemodialysis patients
    Sabatino, Alice
    Kooman, Jeroen P.
    Di Motta, Tommaso
    Cantarelli, Chiara
    Gregorini, Mariacristina
    Bianchi, Stefano
    Regolisti, Giuseppe
    Fiaccadori, Enrico
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2022, 76 (12) : 1719 - 1726
  • [2] Ultrasound-assessed diaphragm dysfunction predicts clinical outcomes in hemodialysis patients
    Zheng, Jing
    Yin, Qing
    Wang, Shi-yuan
    Wang, Ying-Yan
    Xiao, Jing-jie
    Tang, Tao-tao
    Ni, Wei-jie
    Ren, Li-qun
    Liu, Hong
    Zhang, Xiao-liang
    Liu, Bi-Cheng
    Wang, Bin
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [3] Temporal muscle thickness predicts mortality in prevalent hemodialysis patients
    Kara, Ekrem
    Sahutoglu, Tuncay
    Demirbas, Sibel
    Beyazal, Mehmet
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2022, 68 (12): : 1715 - 1720
  • [4] Handgrip Strength and Ultrasonographically-measured Lower Arm Muscle Thickness in Hospitalised Older Adults: The SARCopenia and Ultrasound 3rd Pilot Study
    Acke, Thomas
    De Cock, Anne-Marie
    Maurits, Vandewoude
    Perkisas, Stany
    EUROPEAN JOURNAL OF GERIATRICS AND GERONTOLOGY, 2021, 3 (02): : 108 - 116
  • [5] Handgrip Strength and Mortality in Maintenance Hemodialysis Patients
    Tian, Maolu
    Zha, Yan
    Li, Qian
    Yuan, Jing
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2019, 21 (11)
  • [6] Concordance between muscle mass assessed by bioelectrical impedance analysis and by muscle ultrasound: a cross-sectional study in a cohort of patients on chronic hemodialysis
    Nagy, Eman
    Samaan, Emad
    El-Gamal, Mohamed
    Shamsuddin, Muhammed
    Tharwat, Samar
    BMC NEPHROLOGY, 2024, 25 (01)
  • [7] Assessment of the Correlation Between Serum Phosphate Level and Muscle Strength as Measured by Handgrip Strength in Patients Treated With Hemodialysis
    Ben-Noach, Dror
    Levy, Dina
    Raz, Michal
    Anbar, Ronit
    Schwartz, Doron
    Kliuk-Ben Bassat, Orit
    CANADIAN JOURNAL OF KIDNEY HEALTH AND DISEASE, 2024, 11
  • [8] Association of the modified creatinine index with muscle strength and mortality in patients undergoing hemodialysis
    Tian, Rongrong
    Chang, Liyang
    Liu, Dan
    Luo, Fenxia
    Zhang, Ying
    Cheng, Linghong
    Zhang, Hongmei
    RENAL FAILURE, 2022, 44 (01) : 1732 - 1742
  • [9] Validity of Ultrasound Imaging in Measuring Quadriceps Muscle Thickness and Cross-Sectional Area in Patients Receiving Maintenance Hemodialysis
    Sahathevan, Sharmela
    Khor, Ban-Hock
    Yeong, Chai Hong
    Tan, Teik Hin
    Mohaideen, Abdul Kareem Meera
    Ng, Hi Ming
    Ong, Gild Rick
    Narayanan, Sreelakshmi Sankara
    Gafor, Abdul Halim Abdul
    Goh, Bak Leong
    Bee, Boon Cheak
    Daud, Zulfitri 'Azuan Mat
    Chinna, Karuthan
    Karupaiah, Tilakavati
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2021, 45 (02) : 422 - 426
  • [10] Utility of ultrasound in measuring quadriceps muscle thickness in patients receiving maintenance hemodialysis: comprehensive systematic review and meta-analysis
    Elgenidy, Anas
    Sapoor, Shady
    Abdelrhem, Hasnaa
    Ali, Ahmed Said
    Sulliman, Saif
    Hedawy, Sohieb
    Elgharori, Ayman
    Mady, Hassaan
    Hasan, Wisam Abraheem
    Nasser, Mohamed
    Atta, Esraa Abd elaal
    Ghita, Mohamed
    Aly, Mostafa G.
    Zschuentzsch, Jana
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2024, : 192 - 211