Effects of analysis window on 40-Hz auditory steady-state responses in cochlear implant users

被引:0
|
作者
David, Wouter [1 ]
Verwaerde, Elise [1 ]
Gransier, Robin [1 ]
Wouters, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Neurosci, ExpORL, Herestr 49 Box 721, B-3000 Leuven, Belgium
基金
英国惠康基金;
关键词
Auditory steady-state responses; Cochlear implant; Temporal processing; Signal processing; EVOKED-POTENTIALS; SPEECH-PERCEPTION; FREQUENCY; STIMULATION; THRESHOLDS; TRANSIENT; HEARING;
D O I
10.1016/j.heares.2023.108882
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Auditory steady-state responses (ASSRs) are phase-locked responses of the auditory system to the envelope of a stimulus. These responses can be used as an objective proxy to assess temporal envelope processing and its related functional outcomes such as hearing thresholds and speech perception, in normal-hearing listeners, in persons with hearing impairment, as well as in cochlear-implant (CI) users. While ASSRs are traditionally measured using a continuous stimulation paradigm, an alternative is the intermittent stimulation paradigm, whereby stimuli are presented with silence intervals in between. This paradigm could be more useful in a clinical setting as it allows for other neural responses to be analysed concurrently. One clinical use case of the intermittent paradigm is to objectively program CIs during an automatic fitting session whereby electrically evoked ASSRs (eASSRs) as well as other evoked potentials are used to predict behavioural thresholds. However, there is no consensus yet about the optimal analysis parameters for an intermittent paradigm in order to detect and measure eASSRs reliably. In this study, we used the intermittent paradigm to evoke eASSRs in adult CI users and investigated whether the early response buildup affects the response measurement outcomes. To this end, we varied the starting timepoint and length of the analysis window within which the responses were analysed. We used the amplitude, signal-to-noise ratio (SNR), phase, and pairwise phase consistency (PPC) to characterize the responses. Moreover, we set out to find the optimal stimulus duration for efficient and reliable eASSR measurements. These analyses were performed at two stimulation levels, i.e., 100% and 50% of the dynamic range of each participant. Results revealed that inclusion of the first 300 ms in the analysis window leads to overestimation of response amplitude and underestimation of response phase. Additionally, the response SNR and PPC were not affected by the inclusion of the first 300 ms in the analysis window. However, the latter two metrics were highly dependent on the stimulus duration which complicates comparisons across studies. Finally, the optimal stimulus duration for quick and reliable characterization of eASSRs was found to be around 800 ms for the stimulation level of 100% DR. These findings suggest that inclusion of the early onset period of eASSR recordings negatively influences the response measurement outcomes and that efficient and reliable eASSR measurements are possible using stimuli of around 800 ms long. This will pave the path for the development of a clinically feasible eASSR measurement in CI users.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Phase Delay of the 40 Hz Auditory Steady-State Response Localizes to Left Auditory Cortex in Schizophrenia
    Roach, Brian J.
    Hirano, Yoji
    Ford, Judith M.
    Spencer, Kevin M.
    Mathalon, Daniel H.
    CLINICAL EEG AND NEUROSCIENCE, 2023, 54 (04) : 370 - 378
  • [42] Effects of Residual Hearing on the Auditory Steady State Response for Cochlear Implantation in Children
    Kim, Young Seok
    Han, Sun A.
    Woo, Hyunjun
    Suh, Myung-Whan
    Lee, Jun Ho
    Oh, Seung Ha
    Park, Moo Kyun
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2019, 23 (03): : 153 - 159
  • [43] Hearing aid validation based on 40 Hz auditory steady-state response thresholds
    Sardari, Sara
    Jafari, Zahra
    Haghani, Hamid
    Talebi, Hossain
    HEARING RESEARCH, 2015, 330 : 134 - 141
  • [44] An automatic detection method for 40-Hz auditory steady state response and its application in prognosis of comatose patients
    Chen, Tingting
    Lu, Shiqi
    Qian, Ping
    Chen, Guolin
    Hu, Nan
    CLINICAL NEUROPHYSIOLOGY, 2020, 131 (03) : 703 - 715
  • [45] Detection of Electrically Evoked Auditory Steady-State Responses in Cochlear-Implant Recipients With a System Identification Based Method
    Schott, Julian
    Gransier, Robin
    Wouters, Jan
    Moonen, Marc
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (03) : 738 - 749
  • [46] Human auditory steady-state responses
    Picton, TW
    John, MS
    Dimitrijevic, A
    Purcell, D
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2003, 42 (04) : 177 - 219
  • [47] Evaluating the Modulation Transfer Function of Auditory Steady State Responses in the 65 Hz to 120 Hz Range
    Purcell, David W.
    John, M. Sasha
    EAR AND HEARING, 2010, 31 (05): : 667 - 678
  • [48] Comparison of Auditory Steady-State Responses With Conventional Audiometry in Older Adults
    Tarawneh, Hadeel Y.
    Sohrabi, Hamid R.
    Mulders, Wilhelmina H. A. M.
    Martins, Ralph N.
    Jayakody, Dona M. P.
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [49] Effect of the magnitude of abrupt change in sound pressure on the magnitude and phase synchrony of 40-Hz auditory steady state response
    Motomura, Eishi
    Inui, Koji
    Okada, Motohiro
    NEUROSCIENCE, 2024, 561 : 119 - 126
  • [50] 40 Hz Steady-State Response in Human Auditory Cortex Is Shaped by Gabaergic Neuronal Inhibition
    Toso, Alessandro
    Wermuth, Annika P.
    Arazi, Ayelet
    Braun, Anke
    Grent-'t Jong, Tineke
    Uhlhaas, Peter J.
    Donner, Tobias H.
    JOURNAL OF NEUROSCIENCE, 2024, 44 (24):