Effects of analysis window on 40-Hz auditory steady-state responses in cochlear implant users

被引:0
|
作者
David, Wouter [1 ]
Verwaerde, Elise [1 ]
Gransier, Robin [1 ]
Wouters, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Neurosci, ExpORL, Herestr 49 Box 721, B-3000 Leuven, Belgium
基金
英国惠康基金;
关键词
Auditory steady-state responses; Cochlear implant; Temporal processing; Signal processing; EVOKED-POTENTIALS; SPEECH-PERCEPTION; FREQUENCY; STIMULATION; THRESHOLDS; TRANSIENT; HEARING;
D O I
10.1016/j.heares.2023.108882
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Auditory steady-state responses (ASSRs) are phase-locked responses of the auditory system to the envelope of a stimulus. These responses can be used as an objective proxy to assess temporal envelope processing and its related functional outcomes such as hearing thresholds and speech perception, in normal-hearing listeners, in persons with hearing impairment, as well as in cochlear-implant (CI) users. While ASSRs are traditionally measured using a continuous stimulation paradigm, an alternative is the intermittent stimulation paradigm, whereby stimuli are presented with silence intervals in between. This paradigm could be more useful in a clinical setting as it allows for other neural responses to be analysed concurrently. One clinical use case of the intermittent paradigm is to objectively program CIs during an automatic fitting session whereby electrically evoked ASSRs (eASSRs) as well as other evoked potentials are used to predict behavioural thresholds. However, there is no consensus yet about the optimal analysis parameters for an intermittent paradigm in order to detect and measure eASSRs reliably. In this study, we used the intermittent paradigm to evoke eASSRs in adult CI users and investigated whether the early response buildup affects the response measurement outcomes. To this end, we varied the starting timepoint and length of the analysis window within which the responses were analysed. We used the amplitude, signal-to-noise ratio (SNR), phase, and pairwise phase consistency (PPC) to characterize the responses. Moreover, we set out to find the optimal stimulus duration for efficient and reliable eASSR measurements. These analyses were performed at two stimulation levels, i.e., 100% and 50% of the dynamic range of each participant. Results revealed that inclusion of the first 300 ms in the analysis window leads to overestimation of response amplitude and underestimation of response phase. Additionally, the response SNR and PPC were not affected by the inclusion of the first 300 ms in the analysis window. However, the latter two metrics were highly dependent on the stimulus duration which complicates comparisons across studies. Finally, the optimal stimulus duration for quick and reliable characterization of eASSRs was found to be around 800 ms for the stimulation level of 100% DR. These findings suggest that inclusion of the early onset period of eASSR recordings negatively influences the response measurement outcomes and that efficient and reliable eASSR measurements are possible using stimuli of around 800 ms long. This will pave the path for the development of a clinically feasible eASSR measurement in CI users.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Effects of Contralateral Noise on 40-Hz and 80-Hz Auditory Steady-State Responses
    Maki, Atsuko
    Kawase, Tetsuaki
    Kobayashi, Toshimitsu
    EAR AND HEARING, 2009, 30 (05): : 584 - 589
  • [2] Frequency specificity of 40-Hz auditory steady-state responses
    Ross, B
    Draganova, R
    Picton, TW
    Pantev, C
    HEARING RESEARCH, 2003, 186 (1-2) : 57 - 68
  • [3] Examining the role of novelty detection in 20-and 40-Hz auditory steady-state responses
    Takai, Kentaro
    Sugiyama, Shunsuke
    Inui, Koji
    Ikegame, Yuka
    Yano, Hirohito
    Shinoda, Jun
    Nishihara, Makoto
    Ohi, Kazutaka
    Shioiri, Toshiki
    NEUROIMAGE, 2025, 310
  • [4] The 40-Hz auditory steady-state response in bipolar disorder: A meta-analysis
    Jefsen, Oskar Hougaard
    Shtyrov, Yury
    Larsen, Kit Melissa
    Dietz, Martin J.
    CLINICAL NEUROPHYSIOLOGY, 2022, 141 : 53 - 61
  • [5] Auditory steady-state responses in cochlear implant users: Effect of modulation frequency and stimulation artifacts
    Gransier, Robin
    Deprez, Hanne
    Hofmann, Michael
    Moonen, Marc
    van Wieringen, Astrid
    Wouters, Jan
    HEARING RESEARCH, 2016, 335 : 149 - 160
  • [6] Electrically Evoked Auditory Steady State Responses in Cochlear Implant Users
    Hofmann, Michael
    Wouters, Jan
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2010, 11 (02): : 267 - 282
  • [7] The 40-Hz auditory steady-state response enhanced by beta-band subharmonics
    Sugiyama, Shunsuke
    Taniguchi, Tomoya
    Kinukawa, Tomoaki
    Takeuchi, Nobuyuki
    Ohi, Kazutaka
    Shioiri, Toshiki
    Nishihara, Makoto
    Inui, Koji
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [8] Ketamine increases the amplitude of the 40-Hz auditory steady-state response in humans
    Plourde, G
    Baribeau, J
    Bonhomme, V
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (05) : 524 - 529
  • [9] Auditory steady-state responses to 40-Hz click trains: Relationship to middle latency, gamma band and beta band responses studied with deconvolution
    Presacco, Alessandro
    Bohorquez, Jorge
    Yavuz, Erdem
    Ozdamar, Ozcan
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (09) : 1540 - 1550
  • [10] 40-Hz multiple auditory steady-state responses to narrow-band chirps in sedated and anaesthetized infants
    Muehler, Roland
    Rahne, Torsten
    Mentzel, Katrin
    Verhey, Jesko L.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (05) : 762 - 768