Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study

被引:4
|
作者
Mikulewicz, Marcin [1 ]
Chojnacka, Katarzyna [2 ]
Raszewski, Zbigniew [3 ]
机构
[1] Med Univ Wroclaw, Dept Dentofacial Orthopaed & Orthodont, Div Facial Abnormal, Krakowska 26, PL-50425 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Fac Chem, Dept Adv Mat Technol, Smoluchowskiego 25, PL-50372 Wroclaw, Poland
[3] SpofaDental, Markova 238, Jicin 50601, Czech Republic
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 08期
关键词
tissue conditioners; phthalate-free alternatives; gelling time; adhesion; solubility; GC; Visco Gel; FITT; denture fabrication; biocompatibility; CANDIDA-ALBICANS; ANTIFUNGAL; PLASTICIZER; GELATION; ALCOHOL;
D O I
10.3390/medicina59081359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 C-circle for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = 260.78 +/- 11.31 mu g/mm(2)) compared to F ( -76.12 +/- 7.11 mu g/mm(2)) and experienced faster hardening when stored in distilled water (F = 33.4 +/- 0.30 Sh. A, VG = 59.2 +/- 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 +/- 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A comparison between the tribological and mechanical properties of TiN and TiCN
    Donnelly, N
    McConnell, M
    Dowling, DP
    O'Mahony, JD
    NITRIDES AND OXYNITRIDES, 2000, 325-3 : 141 - 146
  • [42] In vitro comparative study of the surface properties of materials for removable prosthetic bases
    Sampaio-Fernandes, Margarida
    Ferreira Jr, Claudio
    Oliveira, Susana Joao
    Martins, Ramiro Carneiro
    Sampaio-Fernandes, Joao Carlos
    Figueiral, Maria Helena
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 117 - 125
  • [43] Preparation, mechanical properties and in vitro cytocompatibility of multi-walled carbon nanotubes/poly(etheretherketone) nanocomposites
    Cao, Jianfei
    Lu, Yue
    Chen, Hechun
    Zhang, Lifang
    Xiong, Chengdong
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2018, 29 (04) : 428 - 447
  • [44] Mechanical removal of biofilm on titanium discs: An in vitro study
    Ichioka, Yuki
    Derks, Jan
    Dahlen, Gunnar
    Berglundh, Tord
    Larsson, Lena
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2022, 110 (05) : 1044 - 1055
  • [45] Study of Mechanical Properties and Biocompatibility of the Stents
    Xiong, Yonggang
    Tian, Wanpeng
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (12) : 12214 - 12222
  • [46] Understanding biomaterial-tissue interface quality: combined in vitro evaluation
    Gasik, Michael
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2017, 18 (01) : 550 - 562
  • [47] In vitro evaluation of alginate/halloysite nanotube composite scaffolds for tissue engineering
    Liu, Mingxian
    Dai, Libing
    Shi, Huizhe
    Xiong, Sheng
    Zhou, Changren
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 700 - 712
  • [48] A comparison of three mechanical models for cold roll bonding metal laminates
    Steinlage, GA
    Bowman, KJ
    Trumble, KP
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1996, 10 (03) : 199 - 229
  • [49] Evaluation of mechanical properties of ceramic coatings on a metal substrate
    Ohmura, T
    Matsuoka, S
    SURFACE & COATINGS TECHNOLOGY, 2003, 169 : 728 - 731
  • [50] Plasma surface modification of fibroporous polycarbonate urethane membrane by polydimethyl siloxane: Structural characterization, mechanical properties, and in vitro cytocompatibility evaluation
    Arjun, G. N.
    Menon, Girish
    Ramesh, P.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (04) : 947 - 957