Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study

被引:4
|
作者
Mikulewicz, Marcin [1 ]
Chojnacka, Katarzyna [2 ]
Raszewski, Zbigniew [3 ]
机构
[1] Med Univ Wroclaw, Dept Dentofacial Orthopaed & Orthodont, Div Facial Abnormal, Krakowska 26, PL-50425 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Fac Chem, Dept Adv Mat Technol, Smoluchowskiego 25, PL-50372 Wroclaw, Poland
[3] SpofaDental, Markova 238, Jicin 50601, Czech Republic
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 08期
关键词
tissue conditioners; phthalate-free alternatives; gelling time; adhesion; solubility; GC; Visco Gel; FITT; denture fabrication; biocompatibility; CANDIDA-ALBICANS; ANTIFUNGAL; PLASTICIZER; GELATION; ALCOHOL;
D O I
10.3390/medicina59081359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 C-circle for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = 260.78 +/- 11.31 mu g/mm(2)) compared to F ( -76.12 +/- 7.11 mu g/mm(2)) and experienced faster hardening when stored in distilled water (F = 33.4 +/- 0.30 Sh. A, VG = 59.2 +/- 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 +/- 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Development and Evaluation of Fluconazole Co-Crystal for Improved Solubility and Mechanical Properties
    Rathi, Ritu
    Singh, Inderbir
    Sangnim, Tanikan
    Huanbutta, Kampanart
    PHARMACEUTICS, 2025, 17 (03)
  • [32] Microstructural characterization and comparative evaluation of physical, mechanical and biological properties of three ceramics for metal-ceramic restorations
    Kontonasaki, Eleana
    Kantiranis, Nikolaos
    Papadopoulou, Lambrini
    Chatzistavrou, Xanthippi
    Kavouras, Panagiotis
    Zorba, Triantafillia
    Sivropoulou, Afroditi
    Chrissafis, Konstantinos
    Paraskevopoulos, Konstantinos M.
    Koidis, Petros T.
    DENTAL MATERIALS, 2008, 24 (10) : 1362 - 1373
  • [33] Porous Nb-Ti-Ta alloy scaffolds for bone tissue engineering: Fabrication, mechanical properties and in vitro/vivo biocompatibility
    Liu, Jue
    Ruan, Jianming
    Chang, Lin
    Yang, Hailin
    Ruan, Wei
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 78 : 503 - 512
  • [34] Effect of carboxylated graphene nanoplatelets on mechanical and in-vitro biological properties of polyvinyl alcohol nanocomposite scaffolds for bone tissue engineering
    Kaur, Tejinder
    Thirugnanam, Arunachalam
    Pramanik, Krishna
    MATERIALS TODAY COMMUNICATIONS, 2017, 12 : 34 - 42
  • [35] Evaluation of the Fracture Resistance Offered by Three Different Intraorifice Barriers on Obturated Teeth: An In-vitro Study
    Mangaonkar, Sonam
    Foschi, Federico
    Fernandes, Kristlee sabrin
    Chalakkal, Paul
    Kadam, Nilesh
    Lambor, Rajan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (10) : ZC33 - ZC37
  • [36] In-vitro Comparison of the Antimicrobial Properties of Glass Ionomer Cements with Zinc Phosphate Cements
    Dastjerdie, Elaheh Vahid
    Oskoui, Mahvash
    Sayanjali, Elham
    Tabatabaei, Fahimeh Sadat
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2012, 11 (01): : 77 - 82
  • [37] Research on the Mechanical Properties, Fluoride and Monomer Release of a New Experimental Flowable Giomer in Comparison to Three Commercial Flowable Giomers
    Rusnac, Mara Elena
    Prodan, Doina
    Moldovan, Marioara
    Cuc, Stanca
    Filip, Miuta
    Prejmerean, Cristina
    Dudea, Diana
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [38] Magnetic silk fibroin composite nanofibers for biomedical applications: Fabrication and evaluation of the chemical, thermal, mechanical, and in vitro biological properties
    Lalegul-Ulker, Ozge
    Vurat, Murat Taner
    Elcin, Ayse Eser
    Elcin, Yasar Murat
    JOURNAL OF APPLIED POLYMER SCIENCE, 2019, 136 (41)
  • [39] WPI hydrogels as a potential substrate for tissue scaffolds: mechanical properties
    Mia Dvora
    Paityn Warwick
    James E. Henry
    Mechanics of Soft Materials, 2022, 4 (1)
  • [40] A Method for Quantifying Mechanical Properties of Tissue following Viral Infection
    Lam, Vy
    Bigley, Tarin
    Terhune, Scott S.
    Wakatsuki, Tetsuro
    PLOS ONE, 2012, 7 (08):