A Comparison of Capacitive Deionization and Membrane Capacitive Deionization Using Novel Fabricated Ion Exchange Membranes

被引:5
|
作者
Elewa, Mahmoud M. [1 ]
El Batouti, Mervette [2 ]
Al-Harby, Nouf F. [3 ]
机构
[1] Arab Acad Sci Technol & Maritime Transport, POB 1029, Alexandria, Egypt
[2] Alexandria Univ, Fac Sci, Chem Dept, Alexandria 21526, Egypt
[3] Qassim Univ, Coll Sci, Dept Chem, Buraydah 51452, Saudi Arabia
关键词
water; desalination; capacitive deionization; membrane capacitive deionization; charge efficiency; ion exchange membranes; ENHANCED DESALINATION EFFICIENCY; ENERGY-CONSUMPTION; WATER DESALINATION; CONSTANT-CURRENT; CATION-EXCHANGE; ELECTROSORPTION PERFORMANCE; SEAWATER DESALINATION; ELECTRODE MATERIAL; CARBON COMPOSITE; ACTIVATED CARBON;
D O I
10.3390/ma16134872
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Another technique for desalination, known as membrane capacitive deionization (MCDI), has been investigated as an alternative. This approach has the potential to lower the voltage that is required, in addition to improving the ability to renew the electrodes. In this study, the desalination effectiveness of capacitive deionization (CDI) was compared to that of MCDI, employing newly produced cellulose acetate ion exchange membranes (IEMs), which were utilized for the very first time in MCDI. As expected, the salt adsorption and charge efficiency of MCDI were shown to be higher than those of CDI. Despite this, the unique electrosorption behavior of the former reveals that ion transport via the IEMs is a crucial rate-controlling step in the desalination process. We monitored the concentration of salt in the CDI and MCDI effluent streams, but we also evaluated the pH of the effluent stream in each of these systems and investigated the factors that may have caused these shifts. The significant change in pH that takes place during one adsorption and desorption cycle in CDI (pH range: 2.3-11.6) may cause problems in feed water that already contains components that are prone to scaling. In the case of MCDI, the fall in pH was only slightly more noticeable. Based on these findings, it appears that CDI and MCDI are promising new desalination techniques that has the potential to be more ecologically friendly and efficient than conventional methods of desalination. MCDI has some advantages over CDI in its higher salt removal efficiency, faster regeneration, and longer lifetime, but it is also more expensive and complex. The best choice for a particular application will depend on the specific requirements.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Optimization of salt adsorption rate in membrane capacitive deionization
    Zhao, R.
    Satpradit, O.
    Rijnaarts, H. H. M.
    Biesheuvel, P. M.
    van der Wal, A.
    WATER RESEARCH, 2013, 47 (05) : 1941 - 1952
  • [32] Asymmetric Electrode Configuration for Enhanced Membrane Capacitive Deionization
    Omosebi, Ayokunle
    Gao, Xin
    Landon, James
    Liu, Kunlei
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (15) : 12640 - 12649
  • [33] The study of membrane capacitive deionization from charge efficiency
    Li, Haibo
    Nie, Chunyang
    Pan, Likun
    Sun, Zhuo
    DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) : 210 - 215
  • [34] Modification of Cation-Exchange Membranes with Polyelectrolyte Multilayers to Tune Ion Selectivity in Capacitive Deionization
    Sahin, Sevil
    Dykstra, Jouke E.
    Zuilhof, Han
    Zornitta, Rafael L.
    de Smet, Louis C. P. M.
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (31) : 34746 - 34754
  • [35] Enhanced desalination efficiency in modified membrane capacitive deionization by introducing ion-exchange polymers in carbon nanotubes electrodes
    Liu, Yong
    Pan, Likun
    Xu, Xingtao
    Lu, Ting
    Sun, Zhuo
    Chua, Daniel H. C.
    ELECTROCHIMICA ACTA, 2014, 130 : 619 - 624
  • [36] Effects of characteristics of cation exchange membrane on desalination performance of membrane capacitive deionization
    Yoon, Hongsik
    Jo, Kyusik
    Kim, Kwang Je
    Yoon, Jeyong
    DESALINATION, 2019, 458 (116-121) : 116 - 121
  • [37] Semi-continuous capacitive deionization using multi-channel flow stream and ion exchange membranes
    Kim, Choonsoo
    Srimuk, Pattarachai
    Lee, Juhan
    Aslan, Mesut
    Presser, Volker
    DESALINATION, 2018, 425 : 104 - 110
  • [38] Energy Recovery in Membrane Capacitive Deionization
    Dlugolecki, Piotr
    van der Wal, Albert
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (09) : 4904 - 4910
  • [39] Selective removal of lead ions through capacitive deionization: Role of ion-exchange membrane
    Dong, Qianqian
    Guo, Xiaoru
    Huang, Xingkang
    Liu, Lianjun
    Tallon, Rebecca
    Taylor, Bruce
    Chen, Junhong
    CHEMICAL ENGINEERING JOURNAL, 2019, 361 : 1535 - 1542
  • [40] How to achieve the optimal performance of capacitive deionization and inverted-capacitive deionization
    Hu, Chi-Chang
    Hsieh, Chi-Feng
    Chen, Yi-Jing
    Liu, Ching-Fang
    DESALINATION, 2018, 442 : 89 - 98