Upper extremity physical performance tests in female overhead athletes: a test-retest reliability study

被引:2
|
作者
Kardor, Sara [1 ]
Gorji, Zahra [1 ]
Ghotbi, Nastaran [1 ]
Attarbashi-Moghadam, Behrouz [1 ]
Shadmehr, Azadeh [1 ]
Gorji, Mona [2 ]
机构
[1] Univ Tehran Med Sci, Fac Rehabil, Dept Physiotherapy, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Skin Res Ctr, Tehran, Iran
关键词
Reliability; Athletes; Upper extremity; Stability test; Power test; Bland-Altman plot; MEDICINE BALL THROW; STABILITY TEST; SEATED SHOT; SHOULDER; POWER; VALIDITY; STRENGTH; PUSH;
D O I
10.1186/s13018-023-03974-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveDespite the studies that have investigated the reliability of Upper Extremity Functional Tests(UEFTs), the reliability of Closed Kinetic Chain Upper Extremity Stability(CKCUES), Seated Medicine Ball Throw(SMBT), push-up(PU) and Unilateral Seated Shot Put(USSP) tests in overhead athletes has yet to be assessed. The objective of this study was to determine both the relative and absolute test-retest reliability of the four UEFTs in female overhead athletes.MethodsTwenty-nine female overhead athletes (age: 26.6 & PLUSMN; 5.29 years) underwent the four UEFTs twice within a three- day interval. The upper limb stability was assessed through PU and CKCUES tests, while the power was assessed though SMBT and USSP tests. The Intraclass Correlation of Coefficient (ICC) was applied to assess the relative reliability. Absolute reliability was determined by calculating the Standard Error of Measurement (SEM) and the Minimal Detectable Change (MDC). Furthermore, Bland-Altman plots were used to detect the agreements between the two measurements.ResultsThe relative reliability of PU, CKCUES, SMBT, and non-dominant arm USSP tests was excellent (ICC = 0.83, 0.80, 0.91, and 0.83, respectively). SEM was within a range of 1.69 to 1.72 for stability tests and a range of 13.61 to 52.12 for power (based on a 95% confidence interval). The MDC was 4.68 for PU and 4.75 for CKCUES test. At least four repetitions are needed to be considered a real improvement on PU and CKCUES tests. This value was 144.04, in SMBT and 59.03, 37.62 cm (dominant and non-dominant arm, respectively) in USSP tests, which represents the minimum change that must occur to be considered an athlete's progression.ConclusionThis study revealed that both the upper limb stability and power tests have acceptable relative and absolute intra-rater reliability in female overhead athletes. These can be considered as reliable tools in research and clinical settings.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Upper extremity physical performance tests in female overhead athletes: a test–retest reliability study
    Sara Kardor
    Zahra Gorji
    Nastaran Ghotbi
    Behrouz Attarbashi-Moghadam
    Azadeh Shadmehr
    Mona Gorji
    Journal of Orthopaedic Surgery and Research, 18
  • [2] The reliability of upper limb rotation test in overhead athletes and its relationship with selected upper extremity performance tests
    Gultekinler, Birgul Dingirdan
    Tunay, Volga Bayrakci
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2025, 42 : 1002 - 1010
  • [3] Test-retest reliability of physical fitness tests among young athletes: The FITescola® battery
    Henriques-Neto, Duarte
    Minderico, Claudia
    Peralta, Miguel
    Marques, Adilson
    Sardinha, Luis B.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2020, 40 (03) : 173 - 182
  • [4] Reliability of Upper Extremity Functional Performance Tests for the Non-overhead Athlete
    Riemann, Bryan L.
    Davies, George J.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2023, 18 (05):
  • [5] The "upper limb rotation test": Reliability and validity study of a new upper extremity physical performance test
    Decleve, Ph
    Attar, T.
    Benameur, T.
    Gaspar, V
    Van Cant, J.
    Cools, Ann M.
    PHYSICAL THERAPY IN SPORT, 2020, 42 : 118 - 123
  • [6] Reliability of physical performance tests for the upper extremity and trunk using telehealth in athletes
    Goncalves, Gustavo Viotto
    Calixtre, Leticia Bojikian
    Fialho, Hilmaynne Renaly Fonseca
    Jales, Maycon Thomas Moises
    Kamonseki, Danilo Harudy
    Barbosa, Germanna Medeiros
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2025, 42 : 846 - 853
  • [7] Upper-Extremity Functional Performance Tests: Reference Values for Overhead Athletes
    Borms, Dorien
    Cools, Ann
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2018, 39 (06) : 433 - 441
  • [8] Test-retest reliability of the upper extremity questionnaire among keyboard operators
    Salerno, DF
    Franzblau, A
    Armstrong, TJ
    Werner, RA
    Becker, MP
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2001, 40 (06) : 655 - 666
  • [9] Convergent Validity and Test-Retest Reliability of the Unsupported Upper Limb Exercise Test in Patients with Chronic Neck Pain
    Karazeybek, Zeynep Busra
    Naz, Ilknur
    PERCEPTUAL AND MOTOR SKILLS, 2022, 129 (04) : 1177 - 1192
  • [10] Upper-Extremity physical performance tests in older adults: Reference values, reliability and measurement error
    Novais, Maria Eduarda Oliveira
    de Oliveira, Anamaria Siriani
    Moreira, Rayanne de Paula
    Barbosa, Glauber Marques Paraizo
    Lemos, Thiago Vilela
    Matheus, Joao Paulo Chieregato
    de Souza Junior, Jose Roberto
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 40 : 1717 - 1723