Application of homemade portable gas chromatography coupled to photoionization detector for the detection of volatile organic compounds in an industrial park

被引:2
作者
Pang, Xiaobing [1 ,2 ]
Li, Wenke [1 ]
Wang, Shuaiqi [2 ]
Wu, Zhentao [2 ]
Sun, Songhua [3 ]
Lyu, Yan [2 ]
Chen, Dongzhi [4 ]
Li, Haiyan [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
[2] Zhejiang Univ Technol, Coll Environm, Hangzhou 310000, Peoples R China
[3] Shaoxing Ecol & Environm Monitoring Ctr Zhejiang P, Shaoxing 312000, Peoples R China
[4] Zhejiang Ocean Univ, Sch Petrochem Engn & Environm, Zhoushan 316022, Peoples R China
关键词
Portable GC-PID( p GC-PID); Volatile organic compounds (VOCs); Industrial park; Online analysis; OZONE FORMATION; HEALTH-RISK; VOCS; BTEX; PROFILES; LEVEL; GC; EMISSIONS; BENZENE; EXHAUST;
D O I
10.1016/j.chroma.2023.464089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional offline detection of volatile organic compounds (VOCs) requires complex and time-consuming pre-treatments including gas sampling in containers, pre-concentrations, and thermal desorption, which hinders its application in rapid VOCs monitoring. Developing a cost-effective instrument is of great im-portance for online measurement of VOCs. Recently, photoionization detectors (PID) are received great attention due to their fast response time and high sensitivity. This study a portable gas chromatography coupled to PID (pGC-PID) was developed and optimized experimental parameters for the application in online monitoring of VOCs at an industrial site. The sampling time, oven temperature and carrier gas flow rate were optimized as 80 s, 50 & DEG;C and 60 ml & BULL;min -1, respectively. The sampling method is direct injec-tion. Poly tetra fluoroethylene (PTFE) filter membranes were selected to remove particulate matter from interfering with PID. The reproducibility and peak separation were good with relative standard deviations (RSD) < 7%. Good linearities of 27 VOCs standard curves were achieved with R 2 > 0.99, and the detection limits were <10 ppb with the lowest being 2 ppb for 1,1,2-Trichloroethane. Finally, the pGC-PID is suc-cessfully applied in online VOCs monitoring at an industrial site. A total of 17 VOCs species was detected and their diurnal variations were well obtained, indicating pGC-PID is well suited for online analysis in field campaign. & COPY; 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Micro gas preconcentrator using metal organic framework embedded metal foam for detection of low-concentration volatile organic compounds
    Lee, Janghyeon
    Lee, Junsuk
    Lim, Si-Hyung
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 392
  • [42] Quantitative analysis of adsorption and desorption of volatile organic compounds on reusable zeolite filters using gas chromatography
    Lee, Jeongjun
    Jeon, Jihyun
    Im, Jaehyuk
    Jang, Junhwan
    Lee, Jaegun
    Choi, Hee-Jung
    Noh, Beom-Rae
    Kim, Kyoung-Kook
    Cho, Soohaeng
    PLOS ONE, 2020, 15 (01):
  • [43] Determination of 19 volatile organic compounds in wastewater effluents from different treatments by purge and trap followed by gas-chromatography coupled to mass spectrometry
    Barco-Bonilla, Nieves
    Plaza-Bolanos, Patricia
    Luis Fernandez-Moreno, Jose
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    Martinez Vidal, Jose Luis
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3537 - 3546
  • [44] Urinary metabolites for urological cancer detection: a review on the application of volatile organic compounds for cancers
    Gao, Qin
    Lee, Wen-Yee
    AMERICAN JOURNAL OF CLINICAL AND EXPERIMENTAL UROLOGY, 2019, 7 (04): : 232 - 248
  • [45] Simultaneous determination of volatile organic compounds with a wide range of polarities in urine by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry
    Song, Han-Na
    Kim, Chong Hyeak
    Lee, Won-Yong
    Cho, Sung-Hee
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (07) : 613 - 622
  • [46] Analysis of Gas Chromatography-Mass Spectrometry Coupled with Dynamic Headspace Sampling on Volatile Organic Compounds of Heat-Treated Poplar at High Temperatures
    Xue, Lei
    Zhao, Zijian
    Zhang, Yu
    Chu, Demiao
    Mu, Jun
    BIORESOURCES, 2016, 11 (02): : 3550 - 3560
  • [47] Research advance in gas detection of volatile organic compounds released in rice quality deterioration process
    Liu, Kewei
    Zhang, Chao
    Xu, Jinyong
    Liu, Qiaoquan
    COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2021, 20 (06): : 5802 - 5828
  • [48] Investigation on Distribution and Risk Assessment of Volatile Organic Compounds in Surface Water, Sediment, and Soil in a Chemical Industrial Park and Adjacent Area
    Lei, Rongrong
    Sun, Yamei
    Zhu, Shuai
    Jia, Tianqi
    He, Yunchen
    Deng, Jinglin
    Liu, Wenbin
    MOLECULES, 2021, 26 (19):
  • [49] Application of direct thermal desorption gas chromatography and comprehensive two-dimensional gas chromatography coupled to time of flight mass spectrometry for analysis of organic compounds in ambient aerosol particles
    Schnelle-Kreis, J
    Welthagen, W
    Sklorz, M
    Zimmermann, R
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (14) : 1648 - 1657
  • [50] Polymorphism induced gas adsorption on naphthalic imide appended phenothiazine for the detection of volatile organic compounds
    Selvaraj, Kasthuri
    Marappan, Gobinath
    Gawas, Pratiksha
    Raviteja, S.
    Kumar, G. Dinesh
    Surya, Velappa Jayaraman
    Sivalingam, Yuvaraj
    Nutalapati, Venkatramaiah
    MATERIALS LETTERS, 2021, 303