A Comprehensive Overview of Power Converter Applied in High-Power Wind Turbine: Key Challenges and Potential Solutions

被引:72
作者
Catalan, Pedro [1 ]
Wang, Yanbo [2 ]
Arza, Joseba [3 ]
Chen, Zhe [4 ]
机构
[1] Ingeteam, Zamudio 48170, Spain
[2] Aalborg Univ, Energy Technol, DK-9220 Aalborg, Denmark
[3] Ingeteam Technol, Zamudio 48170, Spain
[4] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Wind turbines; Wind power generation; Reliability; Power system reliability; Topology; Power system stability; Costs; Ancillary service; high power; reliability; stability; topology; wind energy conversion system (WECS); wind turbine (WT); ACTIVE-THERMAL-CONTROL; MODULAR MULTILEVEL CONVERTER; RENEWABLE ENERGY-SOURCES; MODEL-PREDICTIVE CONTROL; GRID-CONNECTED VSCS; LOW-VOLTAGE RIDE; OF-THE-ART; ELECTRONIC CONVERTERS; HARMONIC INSTABILITY; STABILITY ANALYSIS;
D O I
10.1109/TPEL.2023.3234221
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing penetration of offshore wind power generation promotes the revolution of wind turbine toward high-power application. The development of high-power wind turbine undoubtedly poses new technical challenges. This article presents a comprehensive overview for high-power wind energy conversion system (WECS) from key technique aspects, including topologies, stability, reliability, and ancillary service capability, and further investigates the key challenges and potential solutions. The various topologies of power converter applied in high-power wind turbine are first reviewed and discussed. The different semiconductor technology, including recent wide bandgap devices, and their potential contributions for offshore high-power converters are discussed. Furthermore, the potential stability issues of high-power WECS are investigated and reviewed. Also, the stabilization control strategies are discussed. Further, the reliability issue and enhancement strategies of high-power WECS are discussed, including condition monitoring, active thermal control strategy, and fault-tolerant operation method. In addition, the ancillary service capability of high-power WECS, including frequency-active power control capability and voltage-reactive power control capability, is reviewed. Finally, the future trends and potential solutions are discussed in this article.
引用
收藏
页码:6169 / 6195
页数:27
相关论文
共 275 条
[1]  
ABB, ABB WIND TURB CONV P
[2]  
Abbey C., 2006, PROC IEEE 37 POWER E, P1
[3]  
Abeynayake Gayan, 2019, 2019 14th Conference on Industrial and Information Systems (ICIIS). Proceedings, P407, DOI 10.1109/ICIIS47346.2019.9063352
[4]   Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC) [J].
Akagi, Hirofumi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (11) :3119-3130
[5]   Impedance-Based Stability Analysis of Multi-Parallel Inverters Applying Total Source Admittance [J].
Alenius, Henrik ;
Berg, Matias ;
Luhtala, Roni ;
Roinila, Tomi ;
Messo, Tuomas .
2019 IEEE 20TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2019,
[6]   Comprehensive assessment of virtual synchronous machine based voltage source converter controllers [J].
Alsiraji, Hasan Alrajhi ;
El-Shatshat, Ramadan .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (07) :1762-1769
[7]  
Amber L, 2017, APPL POWER ELECT CO, P3027, DOI 10.1109/APEC.2017.7931127
[8]  
Andenna M., 2014, PROC IEEE 16 EUR C P, P1, DOI DOI 10.1109/EPE.2014.6910854
[9]  
Andresen B, 2007, 2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, P195
[10]  
Andresen M., 2014, 2014 16th European Conference on Power Electronics and Applications, P1