Pre-analytical and analytical variability of reticulocyte counts in dogs

被引:0
作者
Franchi, Roberta [1 ]
Giraldi, Marco [2 ]
Bertazzolo, Walter [2 ]
Bartolini, Francesca [3 ]
Di Maria, Francesca Maria [4 ]
Paltrinieri, Saverio [4 ]
机构
[1] AniCura Clin Vet Orol, Sasso Marconi, Italy
[2] Vet Diagnost Lab MyLav La Vallonea, Milan, Italy
[3] AniCura Clin Vet Tibaldi, Milan, Italy
[4] Univ Milan, Dept Vet Med & Anim Sci, Lodi, Italy
关键词
automated reticulocyte enumeration; manual count; reticulocytosis; staining artefacts; storage effect; AUTOMATED HEMATOLOGY ANALYZER; ROOM-TEMPERATURE; BLOOD; PARAMETERS; XT-2000IV; STORAGE;
D O I
10.1002/vetr.2733
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundAutomated fluorescence-based haematology analysers are now available for reticulocyte enumeration in veterinary medicine, but manual counting is still largely used. This study aimed to evaluate potential sources of analytical and pre-analytical errors when performing automated and manual counts. MethodsAutomated and two-operator double-blind manual reticulocyte counts were performed on 15 blood samples. The intra-assay variation of the automated and manual counts and the interoperator variation in the manual counts were then calculated. In addition, the effects of storage were evaluated using samples refrigerated at 4 degrees C or stored at room temperature for 2, 4, 12, 24, 48 or 72 hours after sampling. ResultsIntra-assay coefficients of variation were lower for automated counts than for manual counts. Comparison between automated and mean total manual reticulocyte count showed no significant differences. In both refrigerated samples and those stored at room temperature, an increase in reticulocyte count was recorded only after 72 hours. Staining artefacts occurred only in one stored sample counted manually. LimitationsThe presence of cytoplasmic particles other than RNA can cause misinterpretation of cells, leading to an erroneous reticulocyte count. ConclusionThe use of an automated analyser is preferable for reticulocyte enumeration in dogs. Common storage conditions seem to minimally affect reticulocyte evaluation; however, it is recommended to perform the analysis as soon as possible after sampling.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Pre-analytical stability of selected biochemical analytes in serum of horses and oxen stored at -20°C
    Megerssa, Yoseph Cherinet
    Gari, Fikru Regassa
    VETERINARY MEDICINE AND SCIENCE, 2024, 10 (02)
  • [32] Assessment of Pre-Analytical Sample Handling Conditions for Comprehensive Liquid Biopsy Analysis
    Gerber, Teresa
    Taschner-Mandl, Sabine
    Saloberger-Sindhoeringer, Lisa
    Popitsch, Niko
    Heitzer, Ellen
    Witt, Volker
    Geyeregger, Rene
    Hutter, Caroline
    Schwentner, Raphaela
    Ambros, Inge M.
    Ambros, Peter F.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (08) : 1070 - 1086
  • [33] Effect of Pre-analytical Conditions on Prothrombin Time and Partial Activated Thromboplastin Time
    Beatriz, Moutinho
    Beatriz, Pinto
    Rita, Cardoso
    Helena, Alves
    Monica, Botelho
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2019, 20 (04) : 327 - 331
  • [34] Pre-analytical stability before centrifugation of 7 biochemical analytes in whole blood
    Perrier-Cornet, Andreas
    Moineau, Marie-Pierre
    Narbonne, Valerie
    Plee-Gautier, Emmanuelle
    Le Saos, Fabienne
    Carre, Jean-Luc
    ANNALES DE BIOLOGIE CLINIQUE, 2015, 73 (04) : 454 - 460
  • [35] Pre-analytical operating procedures for serum Low Molecular Weight protein profiling
    Di Girolamo, Francesco
    Alessandroni, Jhessica
    Somma, Paolo
    Guadagni, Fiorella
    JOURNAL OF PROTEOMICS, 2010, 73 (03) : 667 - 677
  • [36] The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies
    Bi, Hai
    Guo, Zhengyang
    Jia, Xiao
    Liu, Huiying
    Ma, Lulin
    Xue, Lixiang
    METABOLOMICS, 2020, 16 (06)
  • [37] Pre-analytical processing of plasma and serum samples for combined proteome and metabolome analysis
    Gegner, Hagen M.
    Naake, Thomas
    Dugourd, Aurelien
    Mueller, Torsten
    Czernilofsky, Felix
    Kliewer, Georg
    Jaeger, Evelyn
    Helm, Barbara
    Kunze-Rohrbach, Nina
    Klingmueller, Ursula
    Hopf, Carsten
    Mueller-Tidow, Carsten
    Dietrich, Sascha
    Saez-Rodriguez, Julio
    Huber, Wolfgang
    Hell, Rudiger
    Poschet, Gernot
    Krijgsveld, Jeroen
    FRONTIERS IN MOLECULAR BIOSCIENCES, 2022, 9
  • [38] Evaluation of pre-analytical factors impacting urine test strip and chemistry results
    Bohn, Mary Kathryn
    Fabros, Anselmo
    Di Meo, Ashley
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025, : 1169 - 1178
  • [39] Metabolite Ratios as Quality Indicators for Pre-Analytical Variation in Serum and EDTA Plasma
    Heiling, Sven
    Knutti, Nadine
    Scherr, Franziska
    Geiger, Jorg
    Weikert, Juliane
    Rose, Michael
    Jahns, Roland
    Ceglarek, Uta
    Scherag, Andre
    Kiehntopf, Michael
    METABOLITES, 2021, 11 (09)
  • [40] Impact of pre-analytical parameters on the measurement of circulating microparticles: towards standardization of protocol
    Lacroix, R.
    Judicone, C.
    Poncelet, P.
    Robert, S.
    Arnaud, L.
    Sampol, J.
    Dignat-George, F.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (03) : 437 - 446