SSR Stable Wind Speed Range Quantification for DFIG-Based Wind Power Conversion System Considering Frequency Coupling

被引:10
作者
Du, Chengmao [1 ]
Du, Xiong [2 ]
Tong, Chenghui [3 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Sec, Chongqing, Peoples R China
[2] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Sec, Chongqing, Peoples R China
[3] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Sec, Chongqing, Peoples R China
关键词
Doubly-fed induction generator (DFIG); stable wind speed range; two-variable equivalent admittance; wind power conversion system; STABILITY ANALYSIS; ADMITTANCE MODEL; FARMS; TURBINE; HVDC;
D O I
10.1109/TSTE.2022.3203317
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The subsynchronous resonance (SSR) characteristics of doubly-fed induction generation-based wind power conversion system (DFIG-WPCS) varies with the wind speed. Obtaining the small signal SSR stable wind speed range is urgently important for wind farm dispatch planning. However, there are few methods to quantify the small signal SSR stable wind speed range of DFIG-WPCS. Moreover, the inherent frequency coupling when DFIG-WPCS is integrated to modular multilevel converter-high voltage direct current (MMC-HVDC) may lead to inaccurate stability assessment results. In this article, the frequency coupling mechanism between WPCS and MMC is revealed by analyzing the law of harmonic interaction in the interconnected system. The wind speed-frequency two-variable equivalent admittance model of DFIG-WPCS is established by taking the frequency coupling account. Relying on the two-variable open-loop transfer function, the multiple phase margin contours plot approach is proposed to quantify the small signal SSR stable wind speed range and damping properties. The effectiveness of two-variable admittance and analysis method are validated against electromagnetic transient (EMT) testbed with MATLAB /SimPowerSystems. The analysis results can provide a reference for the early planning and stable operation of DFIG-WPCS.
引用
收藏
页码:125 / 139
页数:15
相关论文
共 34 条
[1]  
Abad G., 2011, DOUBLY FED INDUCTION, DOI [10.1002/9781118104965, DOI 10.1002/9781118104965]
[2]  
[Anonymous], 1977, IEEE Trans. Power App. Syst., V96, P1565
[3]  
[董晓亮 Dong Xiaoliang], 2017, [高电压技术, High Voltage Engineering], V43, P321
[4]   Dynamic Aggregation of Same Wind Turbine Generators in Parallel Connection for Studying Oscillation Stability of a Wind Farm [J].
Du, Wenjuan ;
Dong, Wenkai ;
Wang, Haifeng ;
Cao, Jun .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (06) :4694-4705
[5]   Time-Domain Measurement-Based DQ-Frame Admittance Model Identification for Inverter-Based Resources [J].
Fan, Lingling ;
Miao, Zhixin .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (03) :2211-2221
[6]   Admittance-Based Stability Analysis: Bode Plots, Nyquist Diagrams or Eigenvalue Analysis? [J].
Fan, Lingling ;
Miao, Zhixin .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (04) :3312-3315
[7]   Modeling of DFIG-Based Wind Farms for SSR Analysis [J].
Fan, Lingling ;
Kavasseri, Rajesh ;
Miao, Zhixin Lee ;
Zhu, Chanxia .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2073-2082
[8]  
IEEE PES Wind SSO Taskforce, 2020, TR80 IEEE PES, P1
[9]   Impedance Modeling and Analysis of MMC-HVDC for Offshore Wind Farm Integration [J].
Ji, Ke ;
Tang, Guangfu ;
Pang, Hui ;
Yang, Jie .
IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (03) :1488-1501
[10]   An Improved Single-Machine Equivalent Method of Wind Power Plants by Calibrating Power Recovery Behaviors [J].
Li, Weixing ;
Chao, Pupu ;
Liang, Xiaodong ;
Xu, Dianguo ;
Jin, Xiaoming .