Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:7
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Quantification of ferulic acid using square-wave voltammetric method at an unmodified boron-doped diamond electrode
    Pınar Talay Pınar
    Hemn A. H. Barzani
    Hoshyar Saadi Ali
    Yavuz Yardım
    Monatshefte für Chemie - Chemical Monthly, 2023, 154 : 1225 - 1233
  • [42] The first electrochemical evaluation and voltammetric detection of the insecticide emamectin benzoate using an unmodified boron-doped diamond electrode
    McCormick, Wesley J.
    Robertson, Peter K. J.
    Skillen, Nathan
    McCrudden, Denis
    RESULTS IN CHEMISTRY, 2023, 5
  • [43] Sensitive Voltammetric Method for the Fast Analysis of the Sunagreen Using a Boron Doped Diamond Electrode
    Chylkova, Jaromira
    Tomaskova, Marketa
    Jehlicka, Vladimir
    Selesovska, Renata
    Hlavata, Petra
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 81 - 85
  • [44] Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode
    Maldonado, Vanessa Y.
    Espinoza-Montero, Patricio J.
    Rusinek, Cory A.
    Swain, Greg M.
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6477 - 6485
  • [45] Electrochemical Detection of the Antidiabetic Medication Metformin in Human Urine and Pharmaceutical Tablets Using Boron-Doped Diamond Electrode
    Buzid, Alyah
    Glennon, Jeremy D.
    ANALYTICAL LETTERS, 2025, 58 (07) : 1109 - 1125
  • [46] Porous boron-doped diamond/CNT electrode as electrochemical sensor for flow-injection analysis applications
    Lourencao, Bruna C.
    Pinheiro, Romario A.
    Silva, Tiago A.
    Corat, Evaldo J.
    Fatibello-Filho, Orlando
    DIAMOND AND RELATED MATERIALS, 2017, 74 : 182 - 190
  • [47] Simultaneous voltammetric determination of paracetamol and ascorbic acid using a boron-doped diamond electrode modified with Nafion and lead films
    Tyszczuk-Rotko, Katarzyna
    Beczkowska, Ilona
    Wojciak-Kosior, Magdalena
    Sowa, Ireneusz
    TALANTA, 2014, 129 : 384 - 391
  • [48] Voltammetric Investigation of Antiviral Drug Valacyclovir at a Boron-Doped Diamond Electrode in Different Electrolyte Media: Its Determination Enhanced by Anionic Surfactant in Pharmaceuticals and Biological Fluids
    Pinar, Pinar Talay
    Senturk, Zuhre
    CURRENT PHARMACEUTICAL ANALYSIS, 2017, 13 (02) : 175 - 187
  • [49] The effect of CTAB, a cationic surfactant, on the adsorption ability of the boron-doped diamond electrode: Application for voltammetric sensing of Bisphenol A and Hydroquinone in water samples
    Hoshyar, Saadi Ali
    Barzani, Hemn A. H.
    Yardim, Yavuz
    Senturk, Zuhre
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2021, 610
  • [50] Overoxidized Polypyrrole/Gold Nanoparticles Composite Modified Screen-Printed Voltammetric Sensor for Quantitative Analysis of Methadone in Biological Fluids
    Shafaat, Atefeh
    Faridbod, Farnoush
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (03): : 319 - 330