Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:7
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Voltammetric Analysis of Daminozide after its Acidic Hydrolysis Employing Boron-Doped Diamond Electrode
    Chylkova, Jaromira
    Janikova, Lenka
    Sedlak, Milos
    Bartacek, Jan
    Vana, Jiri
    Selesovska, Renata
    PROCEEDINGS OF INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXIX, 2019, : 100 - 103
  • [32] Using a Boron-Doped Diamond Electrode in Anionic Surfactant Media as an Improved Electrochemical Sensor for the Anticancer Drug Ibrutinib
    Mete, Cihat
    Pinar, Pinar Talay
    CHEMISTRYSELECT, 2023, 8 (06):
  • [33] Voltammetric determination of daminozide and its degradation product N,N-dimethylhydrazine using a boron-doped diamond electrode
    Usenko, Alona
    Chylkova, Jaromira
    Selesovska, Renata
    Sedlak, Milos
    Vana, Jiroi
    Bartacek, Jan
    Mikysek, Tomas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 904
  • [34] Voltammetric sensing of triclosan in the presence of cetyltrimethylammonium bromide using a cathodically pretreated boron-doped diamond electrode
    Yardim, Yavuz
    Alpar, Nurcan
    Senturk, Zuhre
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (13) : 1226 - 1241
  • [35] Sensitive and Rapid Voltammetric Determination of Phenothiazine and Azaphenothiazine Derivatives in Pharmaceuticals Using a Boron-doped Diamond Electrode
    Mielech-Lukasiewicz, Katarzyna
    Staskowska, Elzbieta
    ANALYTICAL SCIENCES, 2015, 31 (10) : 961 - 969
  • [36] Voltammetric determination of traces of 4-chloroaniline in antiseptic samples on a cathodically-treated boron-doped diamond electrode
    Castro, Silvia V. F.
    Silva, Claudiane, V
    Stefano, Jessica S.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 877
  • [37] A disposable screen-printed silver strip sensor for single drop analysis of halide in biological samples
    Chiu, Mei-Hsin
    Cheng, Wan-Ling
    Muthuraman, Govindan
    Hsu, Cheng-Teng
    Chung, Hsieh-Hsun
    Zen, Jyh-Myng
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (10) : 3008 - 3013
  • [38] Self-assembled sensor based on boron-doped diamond and its application in voltammetric analysis of picloram
    Bandzuchova, Lenka
    Svorc, Lubomir
    Vojs, Marian
    Marton, Marian
    Michniak, Pavol
    Chylkova, Jaromira
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (09) : 943 - 953
  • [39] Comparison of carbon paste and boron-doped diamond electrodes for determination of cefepime in pharmaceutical dosage forms and biological samples
    Ozturk, Gokce
    Kul, Dilek
    DIAMOND AND RELATED MATERIALS, 2023, 131
  • [40] Quantification of ferulic acid using square-wave voltammetric method at an unmodified boron-doped diamond electrode
    Pinar, Pinar Talay
    Barzani, Hemn A. H.
    Ali, Hoshyar Saadi
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2023, 154 (11): : 1225 - 1233