Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:7
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Voltammetric determination of harmaline in natural food products using boron-doped diamond electrode
    Svorc, L'ubomir
    Cinkova, Kristina
    Samphao, Anchalee
    Stankovic, Dalibor M.
    Mehmeti, Eda
    Kalcher, Kurt
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 744 : 37 - 44
  • [22] Voltammetric determination of wedelolactone, an anti-HIV herbal drug, at boron-doped diamond electrode
    SACHIN SAXENA
    RATNANJALI SHRIVASTAVA
    SOAMI P SATSANGEE
    Journal of Chemical Sciences, 2015, 127 : 959 - 966
  • [23] Voltammetric Antioxidant Analysis in Mineral Oil Samples Immobilized into Boron-Doped Diamond Micropore Array Electrodes
    Zhang, Xiaohang
    Paddon, Christopher A.
    Chan, Yohan
    Bulman-Page, Philip C.
    Fordred, Paul S.
    Bull, Steven D.
    Chang, Ho-Chol
    Rizvi, Nadeem
    Marken, Frank
    ELECTROANALYSIS, 2009, 21 (12) : 1341 - 1347
  • [24] Sensitive determination and electrochemical evaluation of anticancer drug tofacitinib in pharmaceutical and biological samples using glassy carbon and boron-doped diamond electrodes
    Budak, Fatma
    Cetinkaya, Ahmet
    Kaya, S. Irem
    Atici, Esen Bellur
    Ozkan, Sibel A.
    DIAMOND AND RELATED MATERIALS, 2023, 133
  • [25] Electrochemical sensing of thiabendazole in complex samples using boron-doped diamond electrode
    Paulino Ribeiro, Francisco Wirley
    de Oliveira, Raissa Costa
    de Oliveira, Andre Gadelha
    Nascimento, Ronaldo Ferreira
    Becker, Helena
    de Lima-Neto, Pedro
    Correia, Adriana Nunes
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 866
  • [26] Screen-printed Electrode Based Electrochemical Sensor for the Detection of Isoniazid in Pharmaceutical Formulations and Biological Fluids
    Couto, Rosa A. S.
    Lima, Jose L. F. C.
    Quinaz, M. Beatriz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8738 - 8749
  • [27] Fast, Simple, and Sensitive Voltammetric Measurements of Acyclovir in Real Samples via Boron-Doped Diamond Electrode
    Gorylewski, Damian
    Tyszczuk-Rotko, Katarzyna
    Wojciak, Magdalena
    Sowa, Ireneusz
    MATERIALS, 2024, 17 (18)
  • [28] Electroanalytical application of a boron-doped diamond electrode for sensitive voltammetric determination of theophylline in pharmaceutical dosages and human urine
    Cinkova, K.
    Zbojekova, N.
    Vojs, M.
    Marton, M.
    Samphao, A.
    Svorc, L.
    ANALYTICAL METHODS, 2015, 7 (16) : 6755 - 6763
  • [29] A differential pulse voltammetric method for submicromolar determination of antihistamine drug desloratadine using an unmodified boron-doped diamond electrode
    Nagao, Kayque Y. H.
    Salamanca-Neto, Carlos A. R.
    Coldibeli, Bruna
    Sartori, Elen R.
    ANALYTICAL METHODS, 2020, 12 (08) : 1115 - 1121
  • [30] VOLTAMMETRIC DETERMINATION OF ANTI-MALARIAL DRUG AMODIAQUINE AT A BORON-DOPED DIAMOND ELECTRODE SURFACE IN AN ANIONIC SURFACTANT MEDIA
    Kamal, Sara Kurdo
    Yardim, Yavuz
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2022, 41 (02) : 1 - 12