Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode

被引:7
|
作者
Matvieiev, Oleksandr [1 ]
Selesovska, Renata [1 ]
Sokolova, Romana [2 ]
Jerga, Radek [3 ]
Skopalova, Jana [1 ,3 ]
Bartak, Petr [3 ]
Chylkova, Jaromira [1 ]
Vojs, Marian [4 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Palacky Univ, Fac Sci, Dept Analyt Chem, 17 listopadu 1192-12, Olomouc 77900, Czech Republic
[4] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Mephenoxalone; Voltammetry; Screen-printed sensor with boron-doped dia-mond electrode; GC-MS analysis; Spectroelectrochemistry; COMBINATION; BIOSENSORS; OXIDATION; TOXICITY; RATS;
D O I
10.1016/j.snb.2023.134700
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) for determination of a muscle relaxant and mild anxiolytic mephenoxalone (MNL) was developed. The sensor utilizes the electrochemical oxidation of MNL, which was firstly studied in aqueous solution using oxygen terminated BDDE. MNL provided an irreversible anodic signal at a potential of + 1380 mV (vs. Ag/AgCl/KCl sat.) over a wide pH range. Britton-Robinson buffer (pH 9) was selected as a suitable electrolyte and the square-wave voltammetric method (SWV) was developed. The low detection limit (55 nmol L-1), wide linear dynamic range (0.1-30 mu mol L-1), and good recovery in the analysis of model and pharmaceutical samples (RSD < 1.77%) were attained. Subsequently, the new method was successfully transferred to SPE, which can find application in point-of-care testing. These sensors proved excellent sensitivity and reproducibility in the analysis of biological samples (RSD < 4.94%) without pretreatment and no need of electrolyte. Based on gas chromatography with mass spectrometry (GC-MS) analysis of preparative electrolysis products, a mechanism of the electrochemical oxidation of MNL was proposed, describing the oxidative cleavage of the alkoxybenzene ring. These results were supported with HOMO spatial distribution calculations and atomic charges calculations for arising radical cations, and with spectroelectrochemical measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode
    Keliskova, Pavlina
    Matvieiev, Oleksandr
    Jirouskova, Eliska
    Sokolova, Romana
    Janikova, Lenka
    Behul, Miroslav
    Selesovska, Renata
    TALANTA, 2025, 281
  • [2] Voltammetric and flow amperometric determination of fungicide cyprodinil in environmental samples using screen-printed sensor with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Borovská, Lucie
    Vagenknecht, Gabriela
    Dušek, Libor
    Behul, Miroslav
    Janíková, Lenka
    Šelešovská, Renáta
    Journal of Environmental Chemical Engineering, 2025, 13 (02):
  • [3] Sensitive and eco-friendly voltammetric detection of galantamine using a screen-printed sensor with a functional boron-doped diamond electrode
    Dushna, Olha
    Dubenska, Liliya
    Panas, Krystyna
    Gawor, Andrzej
    Marton, Marian
    Vojs, Marian
    Matvieiev, Oleksandr
    Bulska, Ewa
    TALANTA, 2025, 284
  • [4] Novel Screen-Printed Sensor with Chemically Deposited Boron-Doped Diamond Electrode: Preparation, Characterization, and Application
    Matvieiev, Oleksandr
    Selesovska, Renata
    Vojs, Marian
    Marton, Marian
    Michniak, Pavol
    Hrdlicka, Vojtech
    Hatala, Michal
    Janikova, Lenka
    Chylkova, Jaromira
    Skopalova, Jana
    Cankar, Petr
    Navratil, Tomas
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [5] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Renáta Šelešovská
    Barbora Kränková
    Michaela Štěpánková
    Pavlína Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Tomáš Navrátil
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1701 - 1708
  • [6] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Selesovska, Renata
    Krankova, Barbora
    Stepankova, Michaela
    Martinkova, Pavlina
    Janikova, Lenka
    Chylkova, Jaromira
    Navratil, Tomas
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1701 - 1708
  • [7] Effect of Substrate Size on the Electrochemical Properties of Boron-doped Diamond Powders for Screen-printed Diamond Electrode
    Kondo, Takeshi
    Nakajima, Keito
    Osasa, Takahiro
    Kotsugai, Akihiro
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Aikawa, Tatsuo
    Tojo, Toshifumi
    Yuasa, Makoto
    CHEMISTRY LETTERS, 2018, 47 (12) : 1464 - 1467
  • [8] Boron-doped Diamond Film Electrode as Voltammetric Sensor for Cetirizine
    Culkova, Eva
    Lukacova-Chomistekova, Zuzana
    Bellova, Renata
    Melichercikova, Danica
    Durdiak, Jaroslav
    Timko, Jaroslav
    Rievaj, Miroslav
    Tomcik, Peter
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (07): : 6358 - 6372
  • [9] Voltammetric determination of caffeine in beverage samples on bare boron-doped diamond electrode
    Svorc, Lubomir
    Tomcik, Peter
    Svitkova, Jana
    Rievaj, Miroslav
    Bustin, Dusan
    FOOD CHEMISTRY, 2012, 135 (03) : 1198 - 1204
  • [10] Novel screen-printed sensors with chemically deposited boron-doped diamond and their use for voltammetric determination of attention deficit hyperactivity disorder medication atomoxetine
    Selesovska, Renata
    Navratil, Tomas
    Hrdlicka, Vojtech
    Michniak, Pavol
    Hatala, Michal
    Vojs, Marian
    Marton, Marian
    Matvieiev, Oleksandr
    Janikova, Lenka
    Chylkova, Jaromira
    ELECTROCHIMICA ACTA, 2022, 403