Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system

被引:2
作者
Shibutani, Takayuki [1 ,2 ]
Onoguchi, Masahisa [1 ,2 ]
Kanno, Takayuki [2 ,3 ,4 ]
Kinuya, Seigo [5 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Quantum Med Technol, Kanazawa, Japan
[3] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Japan
[4] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Okayama, Japan
[5] Kanazawa Univ Hosp, Dept Nucl Med, Kanazawa, Japan
关键词
DISA; Spill-over; Small-animal; Scatter correction; Small-animal SPECT/PETCT; Mixed Tc-99m and F-18 solution; DISA SPECT; EMISSION; SINGLE; COMPENSATION; RECONSTRUCTION; I-123-BMIPP; TOMOGRAPHY; SCANNER; MODEL;
D O I
10.1007/s13246-023-01348-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A dual-isotope simultaneous acquisition (DISA) of Tc-99m and F-18 affects the image quality of Tc-99m by crosstalk and spill-over from F-18. We demonstrated the influence of spill-over and crosstalk on image quality and its correction effect for DISA SPECT with Tc-99m and F-18. A fillable cylindrical chamber of 30 mm with NEMA-NU4 image quality phantom was filled with Tc-99m only or a mixed Tc-99m and F-18 solution (C-100). Two small-region chambers were filled with Tc-99m only or a mixed Tc-99m and F-18 solution made at half the radioactivity concentration of C-100 (C-50) and non-radioactive water (C-0). The F-18/Tc-99m ratio for DISA was set at approximately 0.4-12. Two types of Tc-99m transverse images with and without scatter correction (SC and nonSC) were created. The Tc-99m images of single-isotope acquisition (SIA) were created as a reference. The DISA/SIA ratio and contrast of Tc-99m were compared between SIA and DISA. Although the DISA/SIA ratios with nonSC of C-100, C-50 and C-0 gradually increased with increasing (FTc)-F-18-Tc-/99m ratio, it was nearly constant by SC. The contrasts of C-100 and C-50 were similar to a reference value for both nonSC and SC. In conclusion, DISA images showed lower image quality as the F-18/Tc-99m ratio increased. The image quality in hot-spot regions such as C-100 and C-50 was improved by SC, whereas cold-spot regions such as C-0 could not completely remove the influence of spill-over even with SC.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 35 条
[1]   Simultaneous assessment of myocardial perfusion and adrenergic innervation in patients with heart failure by low-dose dual-isotope CZT SPECT imaging [J].
Assante, Roberta ;
D'Antonio, Adriana ;
Mannarino, Teresa ;
Nappi, Carmela ;
Gaudieri, Valeria ;
Zampella, Emilia ;
Buongiorno, Pietro ;
Cantoni, Valeria ;
Green, Roberta ;
Frega, Nicola ;
Verberne, Hein J. ;
Petretta, Mario ;
Cuocolo, Alberto ;
Acampa, Wanda .
JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) :3341-3351
[2]   Protocols for Dual Tracer PET/SPECT Preclinical Imaging [J].
Blower, Julia E. ;
Bordoloi, Jayanta K. ;
Rigby, Alex ;
Farleigh, Matthew ;
Kim, Jana ;
O'Brien, Hugh ;
Jackson, Jonathan ;
Poyiatzis, Constantinos ;
Bezer, James ;
Sunassee, Kavitha ;
Blower, Philip J. ;
Livieratos, Lefteris .
FRONTIERS IN PHYSICS, 2020, 8
[3]   Development of a New Folate-Derived Ga-68-Based PET Imaging Agent [J].
Brand, Christian ;
Longo, Valerie A. ;
Groaning, Mike ;
Weber, Wolfgang A. ;
Reiner, Thomas .
MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (05) :754-761
[4]   Pixel-based subsets for rapid multi-pinhole SPECT reconstruction [J].
Branderhorst, Woutjan ;
Vastenhouw, Brendan ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :2023-2034
[5]   Simultaneous 99mTc/201Tl dual-isotope SPET with Monte Carlo-based down-scatter correction [J].
de Jong, HWAM ;
Beekman, FJ ;
Viergever, MA ;
van Rijk, PP .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (08) :1063-1071
[6]   Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT [J].
Du, Yong ;
Frey, Eric C. .
MEDICAL PHYSICS, 2009, 36 (06) :2021-2033
[7]   Dual SPECT imaging of 111In and 67Ga to simultaneously determine in vivo the pharmacokinetics of different radiopharmaceuticals: a quantitative tool in pre-clinical research [J].
Esquinas, Pedro L. ;
Rodriguez-Rodriguez, Cristina ;
Esposito, Tullio V. F. ;
Harboe, Jeppe ;
Bergamo, Marta ;
Celler, Anna ;
Saatchi, Katayoun ;
Sossi, Vesna ;
Hafeli, Urs O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
[8]   Scatter and crosstalk corrections for 99mTc/123I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators [J].
Fan, Peng ;
Hutton, Brian F. ;
Holstensson, Maria ;
Ljungberg, Michael ;
Pretorius, P. Hendrik ;
Prasad, Rameshwar ;
Ma, Tianyu ;
Liu, Yaqiang ;
Wang, Shi ;
Thorn, Stephanie L. ;
Stacy, Mitchel R. ;
Sinusas, Albert J. ;
Liu, Chi .
MEDICAL PHYSICS, 2015, 42 (12) :6895-6911
[9]   Optimizing modelling in iterative image reconstruction for preclinical pinhole PET [J].
Goorden, Marlies C. ;
van Roosmalen, Jarno ;
van der Have, Frans ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (10) :3712-3733
[10]   VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET [J].
Goorden, Marlies C. ;
van der Have, Frans ;
Kreuger, Rob ;
Ramakers, Ruud M. ;
Vastenhouw, Brendan ;
Burbach, J. Peter H. ;
Booij, Jan ;
Molthoff, Carla F. M. ;
Beekman, Freek J. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (02) :306-312