Relative Water Age in Premise Plumbing Systems Using an Agent-Based Modeling Framework

被引:0
作者
Burkhardt, Jonathan B. [1 ]
Minor, John [2 ]
Platten, William E. [3 ]
Shang, Feng [1 ]
Murray, Regan [1 ]
机构
[1] US Environm Protect Agcy, Off Res & Dev, 26 W Martin Luther King Dr, Cincinnati, OH 45268 USA
[2] Oak Ridge Associated Univ, 26 W Martin Luther King Dr, Cincinnati, OH 45268 USA
[3] US Environm Protect Agcy, Off Water, 26 W Martin Luther King Dr, Cincinnati, OH 45268 USA
关键词
DRINKING-WATER;
D O I
10.1061/JWRMD5.WRENG-5888
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tools used to predict hydraulics and water quality within premise plumbing systems have gained recent interest. An open-source Python-based tool-PPMtools-for modeling and analyzing premise plumbing systems with WNTR or EPANET is presented. A relative water age-the time water has spent in a home-study using three real-world single-family homes was used to demonstrate PPMtools. Results showed that increased use-more people or higher flow fixtures-led to a general decrease in relative water ages. However, even with more use, one user could still experience water for a drinking activity with a relative water age equal to, or longer than, the duration of the longest stagnant period (sleeping or absence from home). Simulations also showed that the general relative water ages increased if the homes were plumbed with larger diameter piping [19.1 mm (3/4 in.) versus 12.7 mm (1/2 in.)]. Hot water heaters were found to have the largest impact on relative water age. Smaller volume uses generally had more variability in relative water ages, while larger volume uses (e.g., showering) resulted in generally low relative water ages with less variability because larger uses fully replaced water in the home with water from the main. This study highlights the potential for using PPMtools to explore more complex water quality modeling within premise plumbing systems.
引用
收藏
页数:13
相关论文
共 28 条
[1]   Modeling Soluble and Particulate Lead Release into Drinking Water from Full and Partially Replaced Lead Service Lines [J].
Abokifa, Ahmed A. ;
Biswas, Pratim .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (06) :3318-3326
[2]  
Blokker E. J. M., 2008, Drinking Water and Engineering Science, V1, P27
[3]  
Blokker M, 2020, WATER AGE TEMPERATUR
[4]  
Blokker M., 2017, DRINK WATER ENG SCI, V10, P1, DOI [10.5194/dwes-10-1-2017, DOI 10.5194/DWES-10-1-2017]
[5]  
Buchberger S. G., 1999, WATER IND SYST MODEL, V1999, P215
[6]  
Buchberger S. G., 2007, PROC WORLD ENV WATER, DOI [10.1061/40927(243)511, DOI 10.1061/40927(243)511]
[7]   MODEL FOR INSTANTANEOUS RESIDENTIAL WATER DEMANDS [J].
BUCHBERGER, SG ;
WU, L .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1995, 121 (03) :232-246
[8]   Intensity, duration, and frequency of residential water demands [J].
Buchberger, SG ;
Wells, GJ .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1996, 122 (01) :11-19
[9]  
Burkhardt J. B, 2023, PRESSURE DEPENDENT A
[10]  
Burkhardt JB, 2020, J WATER RES PLAN MAN, V146, DOI [10.1061/(asce)wr.1943-5452.0001304, 10.1061/(ASCE)WR.1943-5452.0001304]