Immediate versus conventional loading of mandibular implant-retained overdentures: a 3-year follow-up of a randomized controlled trial

被引:2
|
作者
da Rosa Possebon, Anna Paula [3 ]
Schuster, Alessandra Julie [1 ]
Chagas-Junior, Otacilio Luiz [2 ]
Pinto, Luciana de Rezende [3 ]
Faot, Fernanda [3 ]
机构
[1] Univ Fed Pelotas, Sch Dent, Goncalves Chaves St 457, BR-96015560 Pelotas, RS, Brazil
[2] Univ Fed Pelotas, Sch Dent, Dept Oral & Maxillofacial Surg & Maxillofacial Pro, Pelotas, RS, Brazil
[3] Univ Fed Pelotas, Sch Dent, Dept Restorat Dent, Pelotas, RS, Brazil
关键词
Implant-retained mandibular overdentures; Conventional loading; Immediate loading; Masticatory function; Oral health-related quality of life; QUALITY-OF-LIFE; DENTAL IMPLANTS; 2-IMPLANT OVERDENTURES; SATISFACTION; HEALTH; PROTOCOLS; OUTCOMES; IMPACTS; SUPPORT;
D O I
10.1007/s00784-023-05205-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives There is a scarcity of randomized clinical trials (RCT) that report medium- and long-term results and a lack of consensus in the literature on the predictability of immediately loaded unsplinted narrow diameter implants supporting mandibular overdentures. This RCT compared the performance of conventional (CL) and immediate loading (IL) of mandibular overdentures retained by two narrow-diameter implants for 3 years.Materials and methods Patients from an RCT treated with CL or IL were invited to attend to 2- and 3-year follow-ups. Clinical, radiographic, functional, and oral health-related quality of life parameters were evaluated. Prosthetic maintenance events, biological complications, and success and survival rates were also recorded. The data were tested by multilevel mixed-effects linear regression analysis and chi-squared tests.Results The 1-year survival rates of 90% in the CL group and 85% in the IL group were maintained as no implants were lost between 1 and 3 years. The marginal bone loss (MBL) in the IL group was significantly lower after year 3 (-0.04; p < 0.01). Significant changes were found only for the intra-group comparisons in the third year of function: (i) CL and IL presented similar progression of implant stability, MBL, and posterior bone area resorption; (ii) while CL started deteriorating of masticatory function, IL still exhibited functional evolution and (iii) oral comfort domain in the CL and pain domain in the IL were improved.Conclusion Although IL experienced the lowest MBL after 3 years, the outcomes showed that both loading protocols result in predictable medium-term rehabilitation when monitored annually.Clinical relevance It can be expected that in the third year of function, patients with immediate loading may present more complaints related to general performance even with acceptable masticatory function and self-reported improvements in oral comfort.
引用
收藏
页码:5935 / 5946
页数:12
相关论文
共 50 条
  • [21] Immediate and Early Loading of Two-Implant-Supported Mandibular Overdentures: Three-Year Report of Loading Results of a Single-Center Prospective Randomized Controlled Clinical Trial
    ter Gunne, Lotte Pull
    Dikkes, Ben
    Wismeijer, Daniel
    Hassan, Bassam
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1110 - 1116
  • [22] Clinical and radiographic evaluation of three-implant-retained mandibular overdentures: 3-year retrospective study
    Geckili, Onur
    Bilhan, Hakan
    Mumcu, Emre
    QUINTESSENCE INTERNATIONAL, 2011, 42 (09): : 721 - 728
  • [23] Two-center clinical trial of implant-retained mandibular overdentures versus complete dentures - Chewing ability
    Geertman, ME
    Boerrigter, EM
    VantHof, MA
    VanWaas, MAJ
    vanOort, RP
    Boering, G
    Kalk, W
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1996, 24 (01) : 79 - 84
  • [24] Immediate Functional Loading of Implants Placed with Flapless Surgery Versus Conventional Implants in Partially Edentulous Patients: A 3-Year Randomized Controlled Clinical Trial
    Cannizzaro, Gioacchino
    Leone, Michele
    Consolo, Ugo
    Ferri, Vittorio
    Esposito, Marco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (05) : 867 - 875
  • [25] Immediate Functional Loading of Implants Placed with Flapless Surgery Versus Conventional Implants in Partially Edentulous Patients - A 3-Year Randomized Controlled Clinical Trial
    Cannizzaro, Gioacchino
    Leone, Michele
    Consolo, Ugo
    Ferri, Vittorio
    Esposito, Marco
    IMPLANTOLOGIE, 2008, 16 (04): : 391 - 402
  • [26] Healing differences in narrow diameter implants submitted to immediate and conventional loading in mandibular overdentures: A randomized clinical trial
    Bielemann, Amalia Machado
    Marcello-Machado, Raissa Micaella
    Schuster, Alessandra Julie
    Chagas Junior, Otacilio Luiz
    Del Bel Cury, Altair Antoninha
    Faot, Fernanda
    JOURNAL OF PERIODONTAL RESEARCH, 2019, 54 (03) : 241 - 250
  • [27] Immediate versus conventional loading of mandibular implant-supported fixed prostheses in edentulous patients: 10-year report of a randomised controlled trial
    Alfadda, Sara Abdulaziz
    Chvartszaid, David
    Tulbah, Huda Ismail
    Finer, Yoav
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2019, 12 (04) : 431 - 446
  • [28] Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis
    Liu, Wei
    Cai, He
    Zhang, Junjiang
    Wang, Jian
    Sui, Lei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [29] Randomized study on the effect of single-implant versus two implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report
    Alqutaibi, A. Y.
    Kaddah, A. F.
    Farouk, M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (06) : 789 - 797
  • [30] Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial
    Elsyad, Moustafa Abdou
    Al-Mahdy, Yasmeen Fathy
    Fouad, Mohammed Mohammed
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 496 - 503