Accuracy of cuff-less, continuous, and non-invasive blood pressure measurement in 24-h ABPM in children aged 5-17

被引:6
作者
Bothe, Tomas L. [1 ,4 ]
Hulpke-Wette, Martin [2 ]
Barbarics, Boris [2 ]
Patzak, Andreas [3 ]
Pilz, Niklas [3 ]
机构
[1] Charite Univ Med Berlin, Inst Physiol, Ctr Space Med & Extreme Environm Berlin, Berlin, Germany
[2] Prevent Practice Cardiovasc Dis Children & Adolesc, Gottingen, Germany
[3] Charite Univ Med Berlin, Inst Translat Physiol, Berlin, Germany
[4] Charite Univ Med Berlin, Inst Physiol, Ctr space Med & extreme Environm Berlin, Charitepl 1, D-10117 Berlin, Germany
关键词
Blood pressure; blood pressure determination; blood pressure monitoring; ambulatory; hypertension; blood pressure monitors; HYPERTENSION; ASSOCIATION; SOCIETY;
D O I
10.1080/08037051.2023.2255704
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose Ambulatory, cuff-less blood pressure (BP) measurement devices are a promising trend to alleviate the strains of conventional, cuff-based BP determination. Cuff-less devices circumvent discomfort and nocturnal arousal reactions which can be triggered by cuff inflation from conventional, cuff-based ambulatory blood pressure measurement devices. Mitigating these discomforts is especially desirable when performing measurement in children. In this study we want to assess the clinical validity of a cuff-less BP measurement device for 24-h measurements in children and adolescents.Materials and methods We compared the simultaneously retrieved BP data of the cuff-less SOMNOtouch NIBP and the cuff-based Mobil-O-Graph in 24-h use in 90 children in the range from 5 to 17 years old.Results A total of 1218 valid measurement pairs showed a mean deviation of 0.99 mmHg (limits of agreement: 21.44/-19.46) for systolic and 3.03 mmHg (limits of agreement: 24.37/-18.31) for diastolic BP values. Patient-specific difference of means was within 15 mmHg in 97.7% (systolic BP) and 93.2% (diastolic BP) patients. 25.6% of nocturnal cuff inflations led to determinable, BP-relevant arousal reactions.Conclusions The SOMNOtouch NIBP demonstrated little measurement deviation of mean BP compared to the cuff-based technique over a broad spectrum of 24-h, ambulatory BP measurements in children and adolescents. Cuff-less blood pressure measurement relieves the issue of nocturnal arousal reactions which are shown to be frequently induced by cuff-based measurements. Driven by these promising results, we encourage ongoing efforts to create enough evidence on cuff-less BP measurement to promote it into broad clinical application. What is known about the topic? Hypertension is of increasing relevance in children and adolescents Blood pressure measurement is difficult, especially in younger individualsWhat this study adds? The study investigated the accuracy of a cuff-less blood pressure (BP) measurement device, SOMNOtouch & TRADE; NIBP, in children and adolescents for 24-h measurements, in comparison to a traditional cuff-based device. The experiment involved 90 participants aged between 5 and 17 years old, with both devices worn simultaneously for 24 h. The results indicated that the cuff-less device showed a minor average deviation in BP measurements. The mean deviation for systolic and diastolic BP values was 0.99 mmHg and 3.03 mmHg, respectively. About 25.6% of night-time cuff inflations in traditional devices led to significant arousal reactions. The study concluded that the cuff-less device had a slight measurement deviation and could alleviate issues like nocturnal arousal reactions that are common with cuff-based devices. These findings suggest the potential for broad clinical application of cuff-less BP measurement devices, especially in children and adolescents, to reduce discomfort and improve patient adherence. However, more research is needed to solidify these findings.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Prevalence of Hypertension in Children: Applying the New American Academy of Pediatrics Clinical Practice Guideline
    Bell, Cynthia S.
    Samuel, Joyce P.
    Samuels, Joshua A.
    [J]. HYPERTENSION, 2019, 73 (01) : 148 - 152
  • [2] Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Bilo, Grzegorz
    Zorzi, Cristina
    Munera, Juan E. Ochoa
    Torlasco, Camilla
    Giuli, Valentina
    Parati, Gianfranco
    [J]. BLOOD PRESSURE MONITORING, 2015, 20 (05) : 291 - 294
  • [3] The B-Score is a novel metric for measuring the true performance of blood pressure estimation models
    Bothe, Tomas L.
    Patzak, Andreas
    Pilz, Niklas
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Impact of oscillometric measurement artefacts in ambulatory blood pressure monitoring on estimates of average blood pressure and of its variability: a pilot study
    Bothe, Tomas L. L.
    Bilo, Grzegorz
    Parati, Gianfranco
    Haberl, Ralph
    Pilz, Niklas
    Patzak, Andreas
    [J]. JOURNAL OF HYPERTENSION, 2023, 41 (01) : 140 - 149
  • [5] EFFECT OF MEASURING AMBULATORY BLOOD-PRESSURE ON SLEEP AND ON BLOOD-PRESSURE DURING SLEEP
    DAVIES, RJO
    JENKINS, NE
    STRADLING, JR
    [J]. BRITISH MEDICAL JOURNAL, 1994, 308 (6932) : 820 - 823
  • [6] High blood pressure trends in children and adolescents in national surveys, 1963 to 2002
    Din-Dzietham, Rebecca
    Liu, Yong
    Bielo, Marie-Vero
    Shamsa, Falah
    [J]. CIRCULATION, 2007, 116 (13) : 1488 - 1496
  • [7] Daytime and nighttime blood pressure as predictors of death and cause-specific cardiovascular events in hypertension
    Fagard, Robert H.
    Celis, Hilde
    Thijs, Lutgarde
    Staessen, Jan A.
    Clement, Denis L.
    De Buyzere, Marc L.
    De Bacquer, Dirk A.
    [J]. HYPERTENSION, 2008, 51 (01) : 55 - 61
  • [8] Nighttime dipping status and risk of cardiovascular events in patients with untreated hypertension: A systematic review and meta-analysis
    Gavriilaki, Maria
    Anyfanti, Panagiota
    Nikolaidou, Barbara
    Lazaridis, Antonios
    Gavriilaki, Eleni
    Douma, Stella
    Gkaliagkousi, Eugenia
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (11) : 1951 - 1959
  • [9] Underdiagnosis of hypertension in children and adolescents
    Hansen, Matthew L.
    Gunn, Paul W.
    Kaelber, David C.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (08): : 874 - 879
  • [10] Prehypertension and Hypertension in Community-Based Pediatric Practice
    Lo, Joan C.
    Sinaiko, Alan
    Chandra, Malini
    Daley, Matthew F.
    Greenspan, Louise C.
    Parker, Emily D.
    Kharbanda, Elyse O.
    Margolis, Karen L.
    Adams, Kenneth
    Prineas, Ronald
    Magid, David
    O'Connor, Patrick J.
    [J]. PEDIATRICS, 2013, 131 (02) : E415 - E424